TECHNICAL SPECIFICATIONS
Range
Code
Operating Range
in Liquids
Resolution Mounting
NPT
148 0.33 - 6 ft.
0.10 - 1.8 m
0.03”
0.7 mm
1”
ELECTRICAL SPECIFICATIONS
FEATURES
Standard 5 feet of interconnection cable
Simple push-button calibration
Output 4- 20 mA / 20- 4 mA
Built-in temperature compensation
Optional High Level Alarm relay
dual pole output 5A/230 Vac
Optional RS485 communications with
calibration, diagnostics and data
logging software
PLC compatible
Three Wire Operation
APPLICATIONS
Food and Beverages
Water
Pharmaceutical
Mounting Options
Mounting Adaptors Available:
1”- 3/4” NPT or 1”- 1/2” NPT
ENVIRONMENTAL
Temperature : - 40 to 140°F(- 40 to 60°C) PVC Body
Pressure : 1 –10 bar
Installation Category : Class II
MECHANICAL
Std. Interconnection Cable :
5’- Belden #9503 : 3 Pair-24AWG
1) Supply : 12 - 30 Vdc 1 pair shielded (Red/Blk.)
2) Output : 4 - 20 mA 1 Pair shielded (Blk./Green)
3) Comm.:RS485 (optional) 1 Pair Shielded (Blk./Wht.)
Optional Relay Cable :
5’- Belden #9493 : 3-18 AWG unshielded
1) Relay (optional) DPST 5A /230Vac
Enclosure : PVC-94V0
Ingress Protection : NEMA 4X (IP65)
OPERATIONAL
Accuracy : +/-0.10% of max. range
(in lab using 4-20 Ma current output)
+/-0.25% of max. range (typically in field)
Response Time: Standard. Unit 2 - 3 echoes / sec.
: Std. with less damping 6 echoes / sec.
: Fast Protocol ** I.R. 10 echoes / sec.
Or higher ** IF Required
Beam Angle : 10 - 12 degree at –3dB
Loss of Echo : Programmable from 1 min. to 4 min.
(Default = 1 min.) 22mA or 2 mA output
Temp. Comp. : In transducer
Calibration : Push-button or programmable
via optional communications port
Diagnostics :(Echo Profile) via communications port
High Level Alarm 5A. Relay has hysteresis and delay
of 5% of the tank height, this can be adjusted using
Communications software. Relay’s state changes at
20mA calibration point or at 4 mA calibration point. To
switch the above “push-button” or “communication soft-
ware” can be used . Using push-button press and hold
until the light goes off. Continuous green light indicates
alarm at 20mA. ,blinking green indicates alarm at 4 mA.
Relay “ON” set point is adjustable using communica-
tions software.
CATALOGUE # - On the Web return to Home Page &
refer to Catalogue Number Structure for Ordering
information. In Product Documentation refer to page 3.
Power DC 12 to 30 VDC , 0.07 A max @ 24 Vdc
ABM300 R load = (Vs — 6) / 24 mA
Output 4-20 mA Output 6.1 uA resolution
Optional - communications port RS485
- Relay DPST 5A / 230 Vac
4.0”
Mounting 1”NPT
4.0”
New ! Fast Motion Detector
10 echoes / sec. Or Higher
INSTRUCTION MANUAL
For Model U3M Ultrasonic Sensors
Madison Company
Sensor solutions for
today and the future™
MF-017 Rev C ECN 6221, 10/2011