3
MODEL IDENTIFICATION
Acomplete measuring system consists of:
1. One code for ECHOTEL®series 910 electronics and transducer
2. Optional: Code for raised face mounting flanges, consult factory
9 M1 0
APPROVALS/ CABLE ENTRY / HOUSING MATERIALS
A Standard – 3/4" NPT dual cable entry, anti corrosive coated aluminium, non-hazardous
V ATEX – 3/4" NPT dual cable entry, anti-corrosive coated aluminium, explosion proof
W ATEX – M 20 x 1.5 dual cable entry, anti corrosive coated aluminium, explosion proof
5 ATEX – 3/4" NPT single cable entry, stainless steel housing, explosion proof
PROCESS CONNECTION
A Threaded 3/4" NPT connection
2Threaded 1" NPT connection
9 Threaded G1 (1" BSP) connection
3 Sanitary connection - 1 1/2" (compatible with Tri-Clover Tri-Clamp®fittings)
4 Sanitary connection - 2" (compatible with Tri-Clover Tri-Clamp®fittings)
5Sanitary connection - Din 11851 DN 25
6 Sanitary connection - Din 11851 DN 32
7 Sanitary connection - Din 11851 DN 40
8 Sanitary connection - Din 11851 DN 50
1 Ansi flange raised flange - 1" 150 lbs
C Ansi flange raised flange - 1 1/2" 150 lbs
D Ansi flange raised flange - 2" 150 lbs
E Ansi flange raised flange - 1" 300 lbs
F Ansi flange raised flange - 1 1/2" 300 lbs
G Ansi flange raised flange - 2" 300 lbs
H Ansi flange raised flange - 1" 600 lbs
J Ansi flange raised flange - 2" 600 lbs
K EN/DIN flange EN 1092-1 Type A - DN 25/PN 16
L EN/DIN flange EN 1092-1 Type A - DN 40/PN 16
M EN/DIN flange EN 1092-1 Type A - DN 50/PN 16
N EN/DIN flange EN 1092-1 Type A - DN 25/PN 25
PEN/DIN flange EN 1092-1 Type A - DN 40/PN 25
Q EN/DIN flange EN 1092-1 Type A - DN 50/PN 25
R EN/DIN flange EN 1092-1 Type A - DN 25/PN 40
S EN/DIN flange EN 1092-1 Type A - DN 40/PN 40
TEN/DIN flange EN 1092-1 Type A - DN 50/PN 40
U EN/DIN flange EN 1092-1 Type B2 - DN 25/PN 63
V EN/DIN flange EN 1092-1 Type B2 - DN 40/PN 63
W EN/DIN flange EN 1092-1 Type B2 - DN 50/PN 63
XEN/DIN flange EN 1092-1 Type B2 - DN 25/PN 100
Y EN/DIN flange EN 1092-1 Type B2 - DN 40/PN 100
Z EN/DIN flange EN 1092-1 Type B2 - DN 50/PN 100
INPUT POWER / RELAY OUTPUT
1240 V AC/8 A DPDT goldflash relay J240 V AC/5 A DPDT herm. sealed relay
2224 V DC/8 A DPDT goldflash relay K 224 V DC/5 A DPDT herm. sealed relay
0 120 V AC/8 A DPDT goldflash relay H 120 V AC/5 A DPDT herm. sealed relay
TRANSDUCER SPECIFICATION PER CM (0.39") INCREMENTS
0 0 3 30 mm ( 1.2") - minimum insertion length
0 0 5 50 mm ( 2.0") - min length for 1" BSP and flanged process connection
2542540 mm (100.0") - maximum length
BASIC MODEL NUMBER
9 1 0 Echotel 910, ultrasonic level switch with relay
complete code for Echotel 910 alarm switch
Note: Transducer lengths are measured in accordance with process connection style.
– Consult dimensional drawings on page 4.