(BLOWTORCH GAS CYLINDER IS SUPPLIED EMPTY AND WILL NEED
FILLING BEFORE USE)
INSTRUCTIONS FOR USE
It is important to read these instructions carefully and familiarise
yourself with the product before lighting or using. Reread the
instructions periodically to refresh your memory. Retain these
instructions for future reference.
WARNING
1.
IMPORTANT: AFTER EACH FILLING, WAIT FOR TWO MINUTES BEFORE
USE TO ALLOW GAS TO STABILISE AND FOR VAPOUR TO DISSIPATE
2. Read directions before use
3. Only use primary branded aerosol butane gas, available from
kitchenware retailers, BBQ stores and supermarkets.
4. Keep the nozzle clean from dust and do not drop the torch as
these are normal causes for malfunction
5. Do not store under direct sunlight or any place where
temperatures will exceed 4O°C
6. Do not touch flame guard after use
7. Butane gas is extremely flammable. Please handle with care
8. Always point blow torch away from face and clothing when
igniting and operating
9. Make sure the flame lock is turned off and flame is completely
extinguished after each use
10. Do not continually use this tool for more than 1 hour
11. Never puncture or dispose of in a fire
12. Read and follow all instructions and cautions on the fuel canister
13. Do not use to light cigarettes, cigars or pipes
14.
Never loosen or tamper with the filling valve on the base of the torch
15. If stored for long periods of time without use, please safely vent
all gas from the blowtorch prior to storage. To vent, switch the
flame lock on and turn the flame knob anti-clockwise until fully
open. Gas will flow out of the torch. This should be done outside
away from any source of ignition
16. When filled, contains flammable gas under pressure
17. Never carry a blowtorch in hand luggage or check in luggage on
to an aircraft
18. Whilst the adjustable anti-flare flame works at any angle, please
refrain from pointing flame directly downward, as built up heat
may cause damage to the unit We advise an operation angle of
45° downwards
19. Do not the leave the ignited blowtorch unattended when the flame
lock is on
20. After use allow torch to cool down before storing
TEMPREATURE CONTROL
The blue part of the flame is the hottest. A simple way of controlling
temperature is by varying the distance of the blue flame to the object
you are heating. If you need gentle heat, this can be obtained by
increasing the distance.
OPERATING INSTRUCTIONS
NOTE: Primary branded aerosol butane gas can be bought from
kitchenware retailers, BBQ stores and supermarkets.
GAS FILLING
Always fill outdoors in a well ventilated area
Only use primary branded aerosol butane gas
Prior to filling, ensure the gas refill valve is tight
Ensure the flame knob is in the off position – flame knob is turned as
far clockwise as possible (fig A)
Turn the unit upside down and insert fill stem into fill valve (fig B) and
press down for 3-4 seconds, repeat three times Back spray from fill
valve indicates that appliance is full
After filling, allow two minutes for the gas to stabilise before use
Always read and follow all instructions and cautions on the fuel
canister
IGNITING
Turn flame knob anti-clock wise to open flame (fig C)
Gas will flow with a hissing sound from flame guard.
Press and hold ignition button to ignite flame (fig D)
FLAME ADJUSTMENT
Adjust the flame during use by turning the flame knob towards the ‘+’
to make the flame longer, towards the ‘–‘for a shorter flame. For best
results, keep the flame length at about ½-1 inch. Using a longer flame
will cause the flame to become unstable.
For a continuous flame without holding the ignition button, slide flame
lock to lock position, and release the ignition button. This allows you
better control over the direction of the flame.
CAUTION: Use extreme caution when continuous flame is in use as
the flame is activated until the flame lock is manually disengaged.
Do not add attachments to the end of the gas refill canister as the
valve is designed to accept the gas direct from the gas can without
and adaptors added, (these adaptors are usually provided for
cigarette lighters).
TURNING OFF
To turn flame off, simply release the ignition button,
or slide the flame lock button to the off position (fig G).
PROFESSIONAL
BLOWTORCH
A
F
B C
D
G
E
“-” “+”
Do not try to repair
or disassemble any
partsof the torch.
FLAME GUARD
SAFETY
STAND
CONTINUOUS
LOCK LEVER
GAS FLOW
CONTROL KNOB
IGNITION
BUTTON
GAS REFILL VALVE
(NOT SHOWN, UNDER TORCH)
www.master-pro.com.au

Other Masterpro Power Tools manuals

Masterpro MPTORCH2 User manual

Masterpro

Masterpro MPTORCH2 User manual

Masterpro MPTORCHCHEF User manual

Masterpro

Masterpro MPTORCHCHEF User manual

Masterpro CHEF User manual

Masterpro

Masterpro CHEF User manual

Popular Power Tools manuals by other brands

Textron Klauke EBS8CL manual

Textron

Textron Klauke EBS8CL manual

Adkins OMEGA 750 Series Operator's handbook

Adkins

Adkins OMEGA 750 Series Operator's handbook

Bosch IWHT180 Operating/safety instructions

Bosch

Bosch IWHT180 Operating/safety instructions

Festool ROTEX RO 90 DX FEQ Original instructions

Festool

Festool ROTEX RO 90 DX FEQ Original instructions

Bosch MX30E Operating/safety instructions

Bosch

Bosch MX30E Operating/safety instructions

TOOLCRAFT 1525064 operating instructions

TOOLCRAFT

TOOLCRAFT 1525064 operating instructions

Texas ET 850-S 2006/1 user manual

Texas

Texas ET 850-S 2006/1 user manual

Spartan 727 product manual

Spartan

Spartan 727 product manual

Cembre B35-45MD Operation and maintenance manual

Cembre

Cembre B35-45MD Operation and maintenance manual

Logosol M7 manual

Logosol

Logosol M7 manual

Runpotec 20646 quick start guide

Runpotec

Runpotec 20646 quick start guide

IVT PHG-2000 user manual

IVT

IVT PHG-2000 user manual

SUHNER ABRASIVE ROTOset 25-R Technical document

SUHNER ABRASIVE

SUHNER ABRASIVE ROTOset 25-R Technical document

Craftsman 315.115860 Operator's manual

Craftsman

Craftsman 315.115860 Operator's manual

AEG PSD18B-184X Original instructions

AEG

AEG PSD18B-184X Original instructions

Nogval B22 ZERO Operation manuals

Nogval

Nogval B22 ZERO Operation manuals

TRI tool BOILERMASTER Operation manual

TRI tool

TRI tool BOILERMASTER Operation manual

Parkside 93266 Operation and safety notes

Parkside

Parkside 93266 Operation and safety notes

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.