Description
The RF-Panic-One-Button-319-NN is a wireless
handheld or mounted device that when pressed
sends a wireless signal to the alarm panel.
The panic sensor can be used as a police,
medical or auxiliary alarm activation. The
sensor is powered by a replaceable 3-VDC,
lithium coin-cell battery.
Battery Tab
Programming
Pull out battery tab for
operation.
Note: Tighten bottom
screw after removing
battery tab
General Information
The RF-Panic-One-Button-319-NN is a
lithium battery powered operated panic
device for an alarm system. The Panic
provides the user: (specific programming
required for operation)
•Police alarm sounds.
•Medical reporting.
•Silent alarm reporting.
•Auxiliary (local only sounds).
Note: In programming, the sensor should be
enrolled in a supervised group, this
maintains integrity between the panel and
device.
Accessories
The RF-Panic-One-Button-319-NN includes:
RF-Panic-One-Button
Belt Clip
Lanyard Clip
Manual
Mounting Bracket
The following steps describe the general guidelines for
programming the sensor into panel memory. Refer to
the specific panel’s documentation for complete
programming details.
1. Enter panel learn-in/enrollment mode.
2. Select sensor number
3. Select sensor type (specific for panel
type)
4. When the panel request sensor
activation, Press the Panic button.
5. Exit program mode.
Testing and the Sensor
Sensor should be tested for both operation and
range.
Operational Testing
•Press the panic button, the specific
alarm sound should immediately
sound.
•Disarm the system to silence the
alarm.
Wireless Testing
Wireless testing provides a baseline for the
distance the panic will operate away from the
control panel.
•Enter dealer sensor test at the
control panel.
•Press the panic and verify panel
acknowledgement.
•Walk away from the panel and test at various
locations making sure the panel
acknowledges.
RF-Panic-One-Button-319-NN – Wireless Panic
RF-PANIC-One-Button-319-NN Rev.5 10/4/2021
Mounting Bracket
The mounting bracket can be used for a
permanent or temporary mount for the panic.
Using screws mount the bracket in any
orientation.
Note: The belt clip must be installed on the
panic device to fit into the bracket
Mounting
Bracket
The panic with
belt clip
attached
slides into the
mounting
bracket
Note for End-Users:
This device is equipped with a “Heartbeat”
indicator. Every 5 minutes the red LED light
will briefly flash to indicate that the battery is
good and that the Panic is ready to send an
emergency signal.
To initiate an emergency signal; the user
should:
- Press and hold the button for 2 seconds.
Or
- Press the button 2 times.
Battery Replacement
Note: If a low battery alarm occurs, replace the
battery within 7 days.
The RF-Panic-One Button-319 requires (1) 3-
VDC, lithium coin-cell batteries (Varta or
Panasonic, Model CR2450),
1. Remove the cover by removing the
(3) screws
2. Observe polarity when replacing
battery.
CAUTION: Battery may explode if mistreated.
Do not recharge, disassemble or dispose of in
fire.
Specifications
Model no.:
RF frequency:
Compatibility:
Battery type:
Battery:
RF-PANIC-ONE-BUTTON-319
319.5 MHz
Interlogix Learn Mode Panels and
Receivers – Concord, NetworX
and Simon Series.
(1) 3-VDC, lithium coin-cell battery
(Varta or Panasonic, Model
CR2450).
Varta CR2450 or Panasonic
CR2450.
32 to 120°F (0 to 49°C).
-30 to 140°F (-34 to
60°C).
95% non-condensing. 3
x 2 x .7 (L x W x D)
Operating
temperature
range:
Storage
temperature
range:
Relative
humidity:
Dimensions
FCC / IC Statement
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to
radio or television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment
and receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV
technician for help.
This device complies with Industry Canada license-
exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not
RF-Panic-One-Button-319-NN – Wireless Panic
RF-PANIC-One-Button-319-NN Rev.5 10/4/2021
cause interference, and (2) this device must accept
any interference, including interference that may
cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada
exempts de licence standard RSS (s). Son
fonctionnement est soumis aux deux conditions
suivantes: (1) cet appareil ne doit pas provoquer
d'interférences et (2) cet appareil doit accepter toute
interférence, y compris celles pouvant causer un
mauvais fonctionnement de l'appareil.
In accordance with FCC requirements of human
exposure to radio frequency fields, the radiating
element shall be installed such that a minimum
separation distance of 20 cm is maintained from the
general population.
FCC: 2ABBZ-RF-PANIC-319
IC: 11817A-RFPANIC319
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation. Changes or modifications not
expressly approved by the party responsible for
compliance could void the user's authority to operate
the equipment. This Class B digital apparatus
complies with Canadian ICES-3B.
Cet appareil numérique de la classe B est conforme à
la norme NMB-003 du Canada.
MANUFACTURER HEREBY DISCLAIMS ALL
WARRANTIES AND REPRESENTATIONS,
WHETHER EXPRESS, IMPLIED, STATUTORY OR
OTHERWISE INCLUDING (BUT NOT LIMITED TO)
ANY WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE WITH
RESPECT TO THESE PRODUCTS AND ANY
RELATED SOFTWARE. MANUFACTURER
FURTHER DISCLAIMS ANY OTHER IMPLIED
WARRANTY UNDER THE UNIFORM COMPUTER
INFORMATION TRANSACTIONS ACT OR SIMILAR
LAW AS ENACTED BY ANY STATE.
(USA only) SOME STATES DO NOT ALLOW THE
EXCLUSION OF IMPLIED WARRANTIES, SO THE
ABOVE EXCLUSION MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL
RIGHTS AND YOU MAY ALSO HAVE OTHER
LEGAL RIGHTS THAT VARY FROM STATE TO
STATE.
MANUFACTURER MAKES NO REPRESENTATION,
WARRANTY, COVENANT OR PROMISE THAT ITS
ALARM PRODUCTS AND/OR RELATED
SOFTWARE (I) WILL NOT BE HACKED,
COMPROMISED AND/OR CIRCUMVENTED; (II)
WILL PREVENT, OR PROVIDE ADEQUATE
WARNING OR PROTECTION FROM, BREAK-INS,
BURGLARY, ROBBERY, FIRE; OR (III) WILL WORK
PROPERLY IN ALL ENVIRONMENTS.

Other Maxouttech Security Sensor manuals

Maxouttech RF-ARPIR-345-NN User manual

Maxouttech

Maxouttech RF-ARPIR-345-NN User manual

Maxouttech RF-SHK-319-NN User manual

Maxouttech

Maxouttech RF-SHK-319-NN User manual

Maxouttech RF-ROR-135S-345-NN User manual

Maxouttech

Maxouttech RF-ROR-135S-345-NN User manual

Maxouttech RF-RDWS-345-NN User manual

Maxouttech

Maxouttech RF-RDWS-345-NN User manual

Maxouttech RF-ARPIR-319-NN User manual

Maxouttech

Maxouttech RF-ARPIR-319-NN User manual

Maxouttech RF-CPIR-319-NN User manual

Maxouttech

Maxouttech RF-CPIR-319-NN User manual

Maxouttech RF-SHK-319-NN User manual

Maxouttech

Maxouttech RF-SHK-319-NN User manual

Maxouttech RF-RDWS-319-NN User manual

Maxouttech

Maxouttech RF-RDWS-319-NN User manual

Maxouttech RF-CMDWS-OD-345-NN User manual

Maxouttech

Maxouttech RF-CMDWS-OD-345-NN User manual

Maxouttech RF-SHK-345-NN User manual

Maxouttech

Maxouttech RF-SHK-345-NN User manual

Maxouttech RF-ROR-135S-319-NN User manual

Maxouttech

Maxouttech RF-ROR-135S-319-NN User manual

Popular Security Sensor manuals by other brands

BEA MATRIX-3 user guide

BEA

BEA MATRIX-3 user guide

Bruker LYNXEYE XE user manual

Bruker

Bruker LYNXEYE XE user manual

Zumtobel ONLITE manual

Zumtobel

Zumtobel ONLITE manual

PCB Piezotronics M117B66 Installation and operating manual

PCB Piezotronics

PCB Piezotronics M117B66 Installation and operating manual

Smanos MD9260 user manual

Smanos

Smanos MD9260 user manual

Sencon 487 Series Guide

Sencon

Sencon 487 Series Guide

Inficon IRwin quick start guide

Inficon

Inficon IRwin quick start guide

Meccanica Fadini 153L quick start guide

Meccanica Fadini

Meccanica Fadini 153L quick start guide

Yamatake VBC7000 Series installation manual

Yamatake

Yamatake VBC7000 Series installation manual

Solutions UWT NivoGuide 8200 Technical Information/Instruction manual

Solutions

Solutions UWT NivoGuide 8200 Technical Information/Instruction manual

Faraday 8710 installation instructions

Faraday

Faraday 8710 installation instructions

Emerson Rosemount 2160 quick start guide

Emerson

Emerson Rosemount 2160 quick start guide

Energy Saving Sensors HC-22BD installation manual

Energy Saving Sensors

Energy Saving Sensors HC-22BD installation manual

Tiiwee PIR manual

Tiiwee

Tiiwee PIR manual

Optex AX-100TFR Series installation instructions

Optex

Optex AX-100TFR Series installation instructions

Kane KANE-EGD manual

Kane

Kane KANE-EGD manual

Leybold vacuum PhoeniXL300 Technical handbook

Leybold vacuum

Leybold vacuum PhoeniXL300 Technical handbook

MPH Industries SpeedLaser B user manual

MPH Industries

MPH Industries SpeedLaser B user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.