Maytel Multicom MC11 User manual

MC-11 USER MANUAL

Title MC-11 Intercom User Manual Version V1.0
Release 2015.10.
CONTENTS
1. MC-11 INTERCOM FEATURES ..................................................................................... 3
1.1. BUTTONS ................................................................................................................................. 4
1.2. VOLUME CONTROL .................................................................................................................. 4
1.3. GROUP SETTING ...................................................................................................................... 4
1.4. ID SETTING ............................................................................................................................. 5
1.5. TALK FUNCTION ..................................................................................................................... 5
1.6. SPECIFICATIONS .................................................................................................................. 7

Title MC-11 Intercom user Manual Version V1.0
Release 2015.10.
1. MC-11 intercom Features
MODE
LCD
Mode Button
Talk Button
Power Button
Antenna
Headset Jack
AUX Jack
UP Button
Down Button
USB Jack
LED

Title MC-11 Intercom User Manual Version V1.0
Release 2015.10.
1.1. Buttons
Button Function Description
Power Power ON/OFF
Talk Talk channel On/Off
Mode To set group mode or ID mode
Up VOL : To set volume level higher
Down VOL: To set volume level lower
1.2. Volume Control
MC-11 intercom has volume control function that serves user to change volume level wanted.
How to set
VOL is displayed right after power is turned on. The default mode is volume control
mode
In Volume mode, volume can be set with UP/DOWN button in the range of 0 ~ 6.
1.3. Group setting
MC-11 intercom has group setting function that serves user to change group to communicate.
How to set
After turned on, phone is in volume control mode.
To change volume mode into group mode, press Mode buttons Long.

Title MC-11 Intercom user Manual Version V1.0
Release 2015.10.
In Group mode, group can be set with UP/DOWN button in the range of 0 ~ 51.
1.4. ID Setting
MC-11 intercom has ID setting function to communicate with each other. Each intercom has to
have an unique Identification number in the same group and Master’s ID must be set “00” .
How to set
After turned on, phone is in volume control mode.
To change volume mode into group mode, press Mode Button Long
Press Function button to move ID change mode as below.
In ID change mode, ID can be set with UP/DOWN button in the range of 0 ~ 99.
1.5. TALK Function
MC-11 intercom serves TALK function to let users start to talk with others. In case of Master, the
default talk mode in ON, and in case of Slaves the default talk mode is in inactive state. Therefore
Master can start to talk after power is turned on, Slaves are required to press Mode button then
Talk function is activated. Talk function is available in 5 phones including Master at the same time.
While 4 slaves are using Talk, if another slave tries to talk by pressing mode button, Master
release one of 5 slaves that accessed first and allows the latest one to use Talk. In this way 5

Title MC-11 Intercom User Manual Version V1.0
Release 2015.10.
persons can keep talking.

Title MC-11 Intercom user Manual Version V1.0
Release 2015.10.
1.6. SPECIFICATIONS
ITEM SPECIFICATION
Radio Frequency Type ISM 903MHz ~ 926.5MHz
Type Wireless Intercom Unit
Radio Interface ISM 2.4GHz: GFSK Modulation with Frequency Hopping
Voice Codec 16bit/8KHz
Rx Sensitivity -95dBm
Voice Latency < 100ms
Data Rate 250Kbps
Battery Li-ion Battery @3.7V/ TBD 1100mA
Antenna Helical Antenna
Talk Time for Microphone 10hr Typ.
Power Consumption(Microphone) Avg. 100mA
Distance Range(LOS) 300M @ Class 1
Frequency response 50 Hz ~ 4 kHz

903MHz ~926.5MHz
Channel Frequency Channel Frequency Channel Frequency
0 903 20 913 40 923
1 903.5 21 913.5 41 923.5
2 904 22 914 42 924
3 904.5 23 914.5 43 924.5
4 905 24 915 44 925
5 905.5 25 915.5 45 925.5
6 906 26 916 46 926
7 906.5 27 916.5 47 926.5
8 907 28 917
9 907.5 29 917.5
10 908 30 918
11 908.5 31 918.5
12 909 32 919
13 909.5 33 919.5
14 910 34 920
15 910.5 35 920.5
16 911 36 921
17 911.5 37 921.5
18 912 38 922
19 912.5 39 922.5
MC-11 Channel Table
Frequency range :

FCC Information to User
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
con-nected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution
Modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
FCC Compliance Information : This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation
IMPORTANT NOTE:
FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment.
The antennas used for this transmitter must be installed to provide a separation distance of at
least 5mm from all persons and must not be co-located or operating in conjunction with any
other antenna or transmitter.

1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this equipment near water.
6) Do not using near any heat sources such as radiators, heat resisters, stove, or other
equipment that produce heat.
European CE notice to users and product statements
This product is CE marked according to the provisions of the R&TTE
Directive(99/5/EC). Hereby, Maytel Co., Ltd declares that this product is in
compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC.
For further information, please contact http:// swmaytel@naver.com
Maytel Co., Ltd
417 Doosan Venture Digm 126-1, Pyeongchon-dong, Dongan-gu, Anyang-si,
431-070, South Korea
Tel: +82-31-487-5508
Fax: +82-31-440-9331
URL: swmaytel@naver.com

CONTACT INFORMATION
Manufacturer Address : 417 Doosan Venture Digm 126-1, Pyeongchon-dong, Dongan-gu, Anyang-si, 431-070,
South Korea
To locate in-country Maytel Co., Ltd, distributors of the Multicom please refer to the Maytel Co., Ltd Website
http://[email protected]
These distributor(s) represent local contacts for this product.
CORPORATE HEADQUARTERS:
Maytel Co., Ltd
417 Doosan Venture Digm 126-1, Pyeongchon-dong, Dongan-gu, Anyang-si, 431-070, South Korea
Tel: +82-31-487-5508
Fax: +82-31-440-9331
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is Subject to the following two condition: (1) this device may not cause interference
,and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.

EUROPEAN UNION “DECLARATION OF CONFORMITY”
DECLARATION OF CONFORMITY
Maytel Co., Ltd
417 Doosan Venture Digm 126-1, Pyeongchon-dong, Dongan-gu, Anyang-si, 431-070, South Korea
declare under our sole responsibility that the product(s)
Multicom – MC-11
to which this declaration relate(s) is in conformance with the following standards:
EN 301 489-1 V1.9.2:2011
EN 301 489-17 V2.2.1:2012
EN 60950-1:2006/A2:2013
EN 300 328 V1.8.1:2012
following the provisions of the 1999/5/EC Directives.
Other manuals for Multicom MC11
1
Table of contents
Other Maytel Intercom System manuals
Popular Intercom System manuals by other brands

Telex
Telex RadioCom BTR-700 supplementary guide

Panasonic
Panasonic VL-GM001 Installation and operation guide

urmet domus
urmet domus miro 2VOICE 1750 manual

JK Audio
JK Audio Interchange user guide

Farfisa
Farfisa 1SEK/M-KP manual

PS Engineering
PS Engineering PMA7000B Series System installation and operation manual