MCOHome MH-P511-US User manual

www.mcohome.com User Manual
MCOHome Technology Co., Ltd 1
Touch Panel Dimmer
MH-P511-US
Introduction
Touch Panel Dimmer is a wall switch with built-in Z-Wave module. It supports basic
command class ,association command class, which can control all associated devices
synchronously. This product can be included and operated in any Z-Wave network with other
Z-Wave certified devices from any other manufacturers.
Specifications
Power supply: 120VAC, 60Hz
Z-Wave frequency: 908.42MHz (US), 921.4MHz (AH) or other frequency customized
Max output: 1*2.5A
Installation Instructions
IMPORTANT:
A qualified electrician with the understanding of wiring diagrams and knowledge of electrical
safety should complete the installation inside the main circuit box (normally outside your
house)
Read all instructions and documentation and save for future reference
Step1 Preparing
CAUTION: Cut off power supply at circuit breaker or fuse before installation to avoid fire, shock
or death!
Step2 Wiring ( standard strip length: 6-8mm )
1. Separate the device into two parts: the touch panel and the bottom.
2. Connect Hot Line to “L” on the bottom.
3. Connect Neutral Line to “N”.
4. Connect Load wire to “Load”.
5. Secure the bottom onto the junction box with two screws, and then mount the touch panel back.

www.mcohome.com User Manual
MCOHome Technology Co., Ltd 2
Operation
INCLUDING the device into Z-Wave network:
1. Set the controller into INCLUSION mode. Follow instructions provided by controller
manufacturer.
2. Press the key on the panel 3 times in quick succession (within approx 1.5sec).
Note: Check the controller or gateway to see whether inclusion is successful.
EXCLUDING the device from Z-Wave network:
1. Set the controller into EXCLUSION mode. Follow instructions provided by controller
manufacturer.
2. Press the key on the panel 3 times in quick succession (within approx 1.5sec).
Note: Check the controller or gateway to see whether exclusion is successful.
The exclusion will delete all association data.
Turning on/off/Dimming the device:
The device can be controlled by:
Pressing the key on panel will turn on/off the light.
Holding the key on panel will dim up then dim down.
Sending commands through controller or gateway.(the command classes which support this
function are Basic Command Class, Multilevel Switch Command Class, and Scene
Activation Command Class)
Association Group:
The device supports 3 association groups(AG):
1st AG: reports device’s dimming state. It supports only one Node ID. A controller/gateway
SHOULD be associated to this AG.
2nd AG: to control the associated devices synchronously. When S1’s state changes, it will
send “Basic Set Command”to these devices. It supports upto 5 Node IDs.
3rd AG: to control the associated devices synchronously. When S1’s state changes, it will send
“Multi-level Set Command”to these devices. It supports upto 5 Node IDs.
Note: Please refer to table “Parameters Setting”for the detail configurations for AGs.
Setting &Activating Scene:
As a Scene device, it supports “Scene Activation CC”and “Scene Actuator Conf CC”,which
make the device can be added into any scene , and supports 255 Scene ID.
Meanwhile, it can work as a scene controller to activate Scenes. By configuring the
parameters of S1, 3 different scenarios can be realized. The “Scene Activation CC”can be sent to
AG1 (gateway) by “one click”, “double click”or “hold”external button S1. Pls refer to the
following table items 19, 20&21 for more details in configuration.

www.mcohome.com User Manual
MCOHome Technology Co., Ltd 3
Parameters Setting:
Add
Function
Byte
Options
Default
Remark
1
Dimmer state
saved or not when
power down
1
0x00 not saved,Dimmer will be off
when powered again
0x01 saved,Dimmer will keep the same
state when powered again
0x01
2
Beep
1
0x00 Beep disabled
0x01 Beep enabled
0x01
3
LED Backlit
brightness level
1
0x00 LED disabled
0x01~0x0A Min level-Max level
0x0A
4
ALL ON/ALL OFF
1
0x00 forbid ALL ON, forbid ALL OFF
0x01 forbid ALL ON, allow ALL OFF
0x02 allow ALL ON, forbid ALL OFF
0xFF allow ALL ON, allow ALL OFF
0xFF
5
Minimum
brightness level
1
1~98 percentage brightness level
0x01
The max level
should always
higher than min
level
6
Maximum
brightness level
1
2~99 percentage brightness level
0x63
7
Single dimming
step time(Manual)
2
Max 2.55s, in 10ms steps
0x03
(30ms)
Manual control
realized by
holding external
button
8
Single dimming
step size(Manual)
1
1~99 percentage value
(modification isn’t recommended)
0x01
9
Single dimming
step time (Auto)
2
Max 2.55s, in 10ms steps
0x03
(30ms)
Auto control
realized by:
- one click;
- double click of
external button;
- send Z-Wave CC
10
Single dimming
step size (Auto)
1
1~99 percentage value
(modification isn’t recommended)
0x01
11
Timer function
(Auto-off)
2
0x00 function disabled
0x0001~0x00FF 1s~255s
0x00
12
Reserved
13
One click of S1
1
0x00 switch between Off and last saved
brightness level
1~99 percentage value
switch between Off and the set value
99
(0x63)
14
Double click of S1
1
0x00 function disabled
0x01 reach max brightness level
0x01

www.mcohome.com User Manual
MCOHome Technology Co., Ltd 4
SAFETY NOTICE
1. Flush-mount only into a UL/ETL/CE certified plastic junction box and switch panel cover. The
minimum size should be 90*60*50mm, minimum Volume is 270cm3.
2. Use Copper Conductors Only.
3. CAUTION - Risk of Electric Shock - More than one disconnect switch may be required to
de-energize the equipment before servicing.
FCC Warning (Part 15.21) (USAonly)
Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
FCC Interference Statement (Part 15.105 (b)) (USAonly)
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
15
Operation report
from Switch1 to
Association Group
2 & 3
1
bit 6:0
0x00 report all operation to AG2&3
0x01 only report when switching OFF
0x02 only report when switching ON
bit7 (valid for AG3 during dimming only)
0not report during dimming
1report during dimming
0x00
Device send Basic
Set to AG2;
Send Multilevel
Set to AG3.
16
Operation report
from Switch1 to
Association Group
2
1
0x00 When sent Basic Set On,
carried Value is 0xFF
0x01 When sent Basic Set On, carried
Value is Current Dimmer Value
0x01
17
EMPTY
18
EMPTY
19
Scene ID sent to
AG1 when one
click of S1
1
0Scene Activation disabled
1~255 send Activation CC to AG1 with
specified Scene ID
0x00
20
Scene ID sent to
AG1 when double
click of S1
1
0Scene Activation disabled
1~255 send Activation CC to AG1 with
specified Scene ID
0x00
For momentary
button only
21
Scene ID sent to
AG1 when hold S1
1
0Scene Activation disabled
1~255 send Activation CC to AG1 with
specified Scene ID
0x00
For momentary
button only
255
Factory setting
1
0x55 restore factory setting
write only

www.mcohome.com User Manual
MCOHome Technology Co., Ltd 5
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an experienced radio/TV technician for help.
1-year Limited Warranty
We warrant this product to be free from defects in material and workmanship under normal and proper use for one year from
purchase date of the original purchaser. We will, at its option, either repair or replace any part of its products that prove defective
by reason of improper workmanship or materials. THIS LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO
THIS PRODUCT THAT RESULTS FROM IMPROPER INSTALLATION, ACCIDENT, ABUSE, MISUSE, NATURAL
DISASTER, INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY, ABNORMAL MECHANICAL OR
ENVIRONMENTAL CONDITIONS, OR ANY UNAUTHORIZED DISASSEMBLY, REPAIR OR MODIFICATION. This
limited warranty shall not apply if: (i) the product was not used in accordance with any accompanying instructions, or (ii) the
product was not used for its intended function. This limited warranty also does not apply to any product on which the original
identification information has been altered, obliterated or removed, that has not been handled or packaged correctly, that has been
sold as second-hand or that has been resold contrary to Country and other applicable export regulations.
Table of contents