Installation Manual
Type:Enclosed Type Switching Power Supply
(Families: CSP, ENP, ERP, G3, HDP, HEP, HRP, HRPG, HSP, LRS, MSP, NED, NEL, NES,
PSP, PSPA, QP, RS, RSP, RST, SE, SP, SPV, TP, UHP, USP)
Introduction
Enclosed type switching power supplies possess a metal or plastic case for covering their internal PCB and will be
installed inside the case of the end system. Mean Well’s enclosed type power supplies include 2 different groups of
power supplies, with built-in fan and without built-in fan, depending on their rated power or design concept.
Installation
(1)Before any installation or maintenance work, please disconnect your system from the utility.
Ensure that it can’t be re-connected inadvertently!
(2)Keep enough insulation distance between mounting screws and internal components of power supplies. Please
refer to case drawing on specifications to receive the maximum length of mounting screw.
(3)Mounting orientations other than standard orientation or operate under high ambient temperature may
increase the internal component temperature and will require a de-rating in output current. Please refer to
the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(4)Fans and ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept
when the adjacent device is a heat source.
(5)Input and Output terminal
Terminal Screw
Series
Screw Size
Suggested
Torque
RSP-750 / 1000 / 1500 / 2000 / 2400 / 3000
SE-450 / 1000 / 1500
HEP-600,HRP-300,HRPG-300,MSP-300
SP-480,SP-750,SPV-1500,USP-500,RST-10000
M4
10-12kgf-cm
HRP-075 / 100 / 150 / 200,HRPG-150 / 200
LRS-035 / 050 / 075 / 100 / 150 / 150F / 200 / 350
MSP-100 / 200
NED-035 / 050 / 075 / 100,NET-035 / 050 / 075
NES-025 / 035 / 050 / 075 / 100 / 150 / 200 / 350
QP-200 / 320 / 375
RD-050 / 065 / 085 / 125,RID-050 / 065 / 085 / 125
RS-035 / 050 / 075 / 100 / 150
RSP-075 / 100 / 150 / 200 / 320
SP-075 / 100 / 150 / 200 / 240 / 320,SPV-150/300
SE-100 / 200 / 350,HSP-250,PSP-600
M3.5
8-10 kgf-cm
RSP-1600
RD-035,RT-050 / 065 / 085 / 125
RQ-050 / 065 / 085 / 125
TP-075 / 100 / 150,QP-100 / 150
RS-015 / 025
NES-015,USP-150
M3
6-8 kgf-cm
ERP-350
HDP-190 / 240
NEL-200 / 300
#6
8-10 kgf-cm
ENP-120 / 180 / 240 / 360
M2.6
4-5 kgf-cm
Installation Manual
Terminal Screw
Series
Input
Output
Screw Size
Suggested
Torque
Screw Size
Suggested
Torque
HRP-450 / 600
HRPG-450 / 600
MSP-450 / 600 / 1000
SE-600
M3
6-8kgf-cm
M4
10-12kgf-cm
HSP-150 / 200 /300
HSN-200 / 300
M3
6-8kgf-cm
M3.5
8-10kgf-cm
RSP-500
M3.5
8-10kgf-cm
M4
10-12kgf-cm
RST-5000
M4
10-12kgf-cm
M8
10-12kgf-cm
NEL-400
#6
8-10kgf-cm
M3
8-10kgf-cm
UHP-200(R) / 350(R)
M3
5kgf-cm
M3.5
8kgf-cm
UHP-200A
M3.5
13kgf-cm
M3.5
8kgf-cm
CSP-3000
M4
10-12kgf-cm
M6
13kgf-cm
UHP-500(R) / 750 / 1000
M3
5kgf-cm
M4
10-12kgf-cm
HEP-600 / 1000
M4
10-12kgf-cm
M4
10-12kgf-cm
(6)Torque can be various due to different material, please refer to the following chart.
A Recommend torque for aluminum:
Size of screw (Imperial units)
Recommend torque (kgf-cm)
3-56
4-40
4-48
5-40
5-44
6-32
6-40
8-32
8-36
2.3±20%
3.0±20%
3.3±20%
4.5±20%
4.7±20%
5.6±20%
6.3±20%
10.4±20%
10.8±20%
Size of screw (Metric Units)
Recommend torque (kgf-cm)
M2.5
M3
M3.5
M4
M5
M6
M7
M8
2.2±20%
4.1±20%
6.5±20%
9.7±20%
19.5±10%
33.1±10%
55.3±10%
80.6±10%
Installation Manual
B Recommend torque for iron:
Size of screw (Imperial units)
Recommend torque (kgf-cm)
3-56
4-40
4-48
5-40
5-44
6-32
6-40
8-32
8-36
5.0±20%
6.9±20%
7.0±20%
9.4±20%
9.9±20%
12.0±20%
13.4±20%
21.8±20%
23.0±20%
Size of screw (Metric Units)
Recommend torque (kgf-cm)
M2.5
M3
M3.5
M4
M5
M6
M7
M8
4.6±20%
8.8±20%
13.7±20%
20.4±20%
41.1±10%
69.1±10%
117.5±10%
169.4±10%
If above mentioned is not enough due to special application,Nylok Blue Patch screw is recommend, and extra
torque can be added if needed.
(7)Recommended wires are shown as below.
AWG
18
16
14
12
10
8
Rated Current of
Equipment (Amp)
6A
6-10A
10-16A
16-25A
25-32A
32-40A
Cross-section of
Lead(mm2)
0.75
1.00
1.5
2.5
4
6
Note: Current each wire carries should be de-rated to 80% of the current
suggested above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact.
(8)Wiring: The wire color will vary by country, please refer to the table below.
North America
European Harmonized
Live and ACL
Black
Brown
Neutral and ACN
white
Blue
PE and FG (Class I only)
Green
Green/yellow
(a)Connect the FG wire (green or green/yellow) of the power supply to PE (green or green/yellow), this step
can be skipped when the unit is marked class II, ungrounded.
(b)Connect the ACL wire (black or brown) of the power supply to Live (black or brown).
(c)Connect the ACN wire (white or blue) of the power supply to Neutral (white or blue).
(d)Make sure all wires are secured to prevent poor contact.
Installation Manual
(9)For other information about the products, please refer to www.meanwell.com for details.
Warning / Caution !!
(1)Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
(2)Please do not install power supplies in places with high moisture or near the water.
(3)Please do not install power supplies in places with high ambient temperature or near fire source. The
maximum ambient temperature please refer to their specifications.
(4)Output current and output wattage must not exceed the rated values on specifications.
(5)The ground(FG) must be connected to earth ground.
(6)All MW’s PSUs are designed in accordance with EMC regulations and the related test reports are available by
request. Since they are belong to component power supplies and will be installed inside system enclosure,
when they are integrated into a system, the EMC characteristics of the end system must be re-verified again.
(7)This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(a) This device may not cause harmful interference, and
(b) this device must accept any interference received, including interference that may cause undesired
operation.operation.
(8)For series of LRS, NES, PSP, PSPA, RD, RSP, RS, SE that certified with BSMI approvals, flammability of V1 or
above is required for surrounding equipment and operation of this equipment in a residential environment
could cause radio interference.
PSU
PSU
Installation Manual
Manufacturer:
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office:
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
No.11, Jingu South Road, Huadong
Town, Huadu Distric, Guangzhou,
Gungzhou, China
Tel: +86-20-3773-7100
Web: www.meanwell.com.cn
China
SUZHOU MEAN WELL
TECHNOLOGY Co., LTD.
No.77, Jian-Ming Rd. Dong-Qiao,
Pan-Yang lnd. Park, Huang-Dai
Town, Xiang-Cheng District,
Suzhou, Jiang-Su, China
Post Code:215152
Tel: +86-512-6508-8600
Web: www.meanwell.cc
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT Amstelveen, The
Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu
Declaration of China RoHS Conformity
In order to reduce the impacts on the environment and take the more responsibility for protecting the
earth, MEAN WELLis confirming and announcing the conformity to China RoHS, an
Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and
Electronic Products.
Environment Friendly Use Period Label
Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous
Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly
Use Period of Electronic Information ProductsAppendix B, adopting
table look-up to verify the Environment Friendly Use Period
Names and Contents of Hazardous Substances Lists
Part Name
Hazardous Substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr6+)
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
PCB and its
components
X
O
X
O
O
O
Metal structure
parts
X
O
O
O
O
O
Plastic structure
parts
O
O
O
O
O
O
Accessories
O
O
O
O
O
O
Cables
X
O
O
O
O
O
O: The concentration of the hazardous substances within the homogeneous material of that product is less than
the concentration limits set by GB/T 26572-2011.
X: The concentration of the hazardous substances within the homogeneous material of that product is over the
concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.
Declaration of China VOC Conformity
In order to reduce the impacts on the environment and take the more responsibility
for protecting the earth, MEAN WELL is confirming and announcing the conformity to
China’s Standardization Administration Releases VOC Standards
Standard No. Name of the Standard
GB 30981-2020 Limit of harmful substances of industrial protective coatings
GB 33372-2020 Limits for volatile organic compounds content in adhesive
GB 38507-2020 Limits for volatile organic compounds (VOCs) In printing ink
GB 38508-2020 Limits for volatile organic compounds content in cleaning agents
Declaration of Five PBT TSCA Conformity
In order to reduce the impacts on the environment and take the more responsibility
for protecting the earth, MEAN WELL hereby confirms that MEAN WELL product
series comply with Use and Risk Management for Five PBT Chemicals under TSCA
section 6(h)
CAS No.
Substance Name
1163-19-5
Decabromodiphenyl ether (DecaBDE)
68937-41-7
Phenol, isopropylated, phosphate (3:1)
PIP (3:1)
732-26-3
2,4,6-Tris (tert-butyl) phenol (2,4,6-TTBP)
133-49-3
Pentachlorothiophenol (PCTP)
87-68-3
Hexachlorobutadiene (HCBD)

Other manuals for HEP-1000

2

This manual suits for next models

162

Other Meanwell Power Supply manuals

Meanwell RCP Series User manual

Meanwell

Meanwell RCP Series User manual

Meanwell SHP-30K-HV Series User manual

Meanwell

Meanwell SHP-30K-HV Series User manual

Meanwell LAD Series User manual

Meanwell

Meanwell LAD Series User manual

Meanwell SHP-10K Series User manual

Meanwell

Meanwell SHP-10K Series User manual

Meanwell HEP-1000 User manual

Meanwell

Meanwell HEP-1000 User manual

Meanwell DRP-3200 Series User manual

Meanwell

Meanwell DRP-3200 Series User manual

Meanwell HEP-2300 Series User manual

Meanwell

Meanwell HEP-2300 Series User manual

Meanwell RCP-1000 Series User manual

Meanwell

Meanwell RCP-1000 Series User manual

Meanwell DRS Series User manual

Meanwell

Meanwell DRS Series User manual

Meanwell CSP Series User manual

Meanwell

Meanwell CSP Series User manual

Meanwell PWR-40-24 User manual

Meanwell

Meanwell PWR-40-24 User manual

Meanwell DRA-40 Series User manual

Meanwell

Meanwell DRA-40 Series User manual

Meanwell RKP-1U-CMU1 User manual

Meanwell

Meanwell RKP-1U-CMU1 User manual

Meanwell NMP650 User manual

Meanwell

Meanwell NMP650 User manual

Meanwell DRH-120-24 User manual

Meanwell

Meanwell DRH-120-24 User manual

Meanwell MP450 User manual

Meanwell

Meanwell MP450 User manual

Meanwell LCM-40KN User manual

Meanwell

Meanwell LCM-40KN User manual

Meanwell ELG-150-C Series User manual

Meanwell

Meanwell ELG-150-C Series User manual

Meanwell AP User manual

Meanwell

Meanwell AP User manual

Meanwell TDR-240-24 User manual

Meanwell

Meanwell TDR-240-24 User manual

Meanwell DRDN20 User manual

Meanwell

Meanwell DRDN20 User manual

Meanwell DDR-480B-12 User manual

Meanwell

Meanwell DDR-480B-12 User manual

Meanwell NDR-240 Series User manual

Meanwell

Meanwell NDR-240 Series User manual

Meanwell DDR-120A-12 User manual

Meanwell

Meanwell DDR-120A-12 User manual

Popular Power Supply manuals by other brands

TDK-Lambda GENESYS 750W HALF RACK user manual

TDK-Lambda

TDK-Lambda GENESYS 750W HALF RACK user manual

EFOY Updater user manual

EFOY

EFOY Updater user manual

Altronix DN200 installation guide

Altronix

Altronix DN200 installation guide

Power One SFP450 Series Programming manual

Power One

Power One SFP450 Series Programming manual

ELC ALR3003D instruction manual

ELC

ELC ALR3003D instruction manual

ASL INTERCOM PS 285 user manual

ASL INTERCOM

ASL INTERCOM PS 285 user manual

Oxford Instruments TC948 instruction manual

Oxford Instruments

Oxford Instruments TC948 instruction manual

Pulsar PSBS 5012D quick start guide

Pulsar

Pulsar PSBS 5012D quick start guide

Altronix AL300ULX installation guide

Altronix

Altronix AL300ULX installation guide

Cloudray MYJG-40 user manual

Cloudray

Cloudray MYJG-40 user manual

SloanLED 701507-60C3D installation guide

SloanLED

SloanLED 701507-60C3D installation guide

SPECS HSA3500 user manual

SPECS

SPECS HSA3500 user manual

Lutron Electronics T120-15DC-9-BL installation instructions

Lutron Electronics

Lutron Electronics T120-15DC-9-BL installation instructions

Avaya 1151C1 Installation and safety instructions

Avaya

Avaya 1151C1 Installation and safety instructions

Lucent Technologies INDeX 20DS Turret user guide

Lucent Technologies

Lucent Technologies INDeX 20DS Turret user guide

Keithley 2230 Series quick start guide

Keithley

Keithley 2230 Series quick start guide

Wirepath WP-PS Series Installation and user manual

Wirepath

Wirepath WP-PS Series Installation and user manual

Alpha Lectro 60V user guide

Alpha

Alpha Lectro 60V user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.