12
24V
5A 3.2A
3.7A
OUTPUT
(MD-100)
DC VOLTAGE
OUTPUT VOLTAGE CODE MD-100R MD-100S MD-100T MD-100U MD-100V MD-100X
5V 5V 5V 15V5V 12V 15V 24V 15V
10A 10A 10A 4A8A 4.2A 3.4A 2.5A 2.7A
2 ~ 10A 2 ~ 10A 2 ~ 10A 0 ~ 4.7A
1 ~ 4.7A
0 ~ 8A 0 ~ 5.8A
0.5 ~ 3A
0 ~ 4.7A
90W 100.4W 101W 100W 100.5W
100mVp-p 150mVp-p 150mVp-p 200mVp-p 150mVp-p100mVp-p 100mVp-p 100mVp-p 150mVp-p
4.75 ~ 5.5V 4.75 ~ 5.5V 4.75 ~ 5.5V 4.75 ~ 5.5V
14.2 ~ 16.5V 14.2 ~ 16.5V
11.4 ~ 13.2V 14.2 ~ 16.5V
22.8 ~ 26.4V
4.75 ~ 5.5V
±3.0%±3.0% ±3.0% ±3.0% ±3.0%±3.0% ±3.0% ±3.0% ±3.0%±2.0%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%±1.0% ±1.0% ±1.0% ±1.0%±0.5%
±2.0%±2.0% ±2.0% ±2.0% ±2.0%±2.0% ±2.0% ±2.0% ±2.0%±1.0%
1500ms, 50ms, 20ms at full load
■1 SLOT Isolated Dual output (100W) MD-100
RATED CURRENT
CURRENT RANGE
RATED POWER Note.6
RIPPLE & NOISE (max.) Note.2
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD UP TIME
105 ~ 150% rated output power
5V
8A
0 ~ 10A
100mVp-p
12V
3.4A
0 ~ 4.7A
100.8W
120mVp-p
11.4 ~ 13.2V
±3.0%
±2.0%
±1.0%
±0.5%
±2.0%
±1.0%
24V
2.5A
0.6 ~ 3A
240mVp-p
22.8 ~ 26.4V
12V 12V
5A 3.4A
1 ~ 5A
0 ~ 5.8A
100.8W
120mVp-p 120mVp-p
11.4~ 13.2V 11.4~ 13.2V
±3.0%±2.0%
±1.0%±0.5%
±2.0%±1.0%
MD-100W
OVERLOAD
OVER VOLTAGE
PROTECTION
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
5.6 ~ 7.2V 5.6 ~ 7.2V 5.6 ~ 7.2V 5.6 ~ 7.2V
13.3 ~ 17V
16.6 ~ 22V
16.6 ~ 22V 16.6 ~ 22V
26.5 ~ 34V
5.6 ~ 7.2V
13.3 ~ 17V
26.5 ~ 34V 13.3 ~ 17V 13.3 ~ 17V
REMOTE INHIBIT CONTROL RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON RC+/RC-: 4 ~ 12V POWER OFF
FUNCTION
±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2%
±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
1500ms, 50ms, 20ms at full load
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD UP TIME
OVERLOAD
OVER VOLTAGE
PROTECTION
116 ~ 150% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
4.1 ~ 5V 6.1 ~ 7.5V 13.3 ~ 18V 16.9 ~ 22V 26.5 ~ 35V 53.1 ~ 60V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
REMOTE INHIBIT CONTROL RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON RC+/RC-: 4 ~ 12V POWER OFF
FUNCTION
OUTPUT
(MS-75)
DC VOLTAGE
OUTPUT VOLTAGE CODE
3.3V 5V 12V 15V 48V
15A 15A 6.3A 1.6A
0 ~ 15A 0 ~ 15A 0 ~ 6.3A 0 ~ 5A 0 ~ 3.2A 0 ~ 1.6A
17.3A 17.3A 7.3A 5.8A 1.8A
49.5W 75W 75.6W 75W 76.8W 76.8W
80mVp-p 80mVp-p 150mVp-p 150mVp-p 150mVp-p 250mVp-p
2.6 ~ 4V 4 ~ 6V 9 ~ 13.2V
13.2 ~ 16.8V
20 ~ 26.4V 40 ~ 53V
±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
MS-75L MS-75M MS-75N MS-75O MS-75P MS-75Q
■1 SLOT Single output (75W) MS-75
RATED CURRENT
CURRENT RANGE
PEAK LOAD Note.4
RATED POWER
RIPPLE & NOISE (max.) Note.2
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
NOTE 1. MP450:The value changed by installing different output odules. The efficiency in specification eans output odules are co posed by following odules.
5V(Voltage code C)*1, 12V(Voltage code E)*1, 24V(Voltage code H)*1, 5V(Voltage code M)*1.
MP650:The value changed by installing different output odules. The efficiency in specification eans output odules are co posed by following odules.
5V(Voltage code C)*2, 12V(Voltage code E)*1, 24V(Voltage code H)*2.
MP1K0:The value changed by installing different output odules. The efficiency in specification eans output odules are co posed by following odules.
5V(Voltage code C)*2, 12V(Voltage code E)*2, 24V(Voltage code H)*3.
The hold-up ti e of above co bination is 20 s(typ.)
2. Ripple & noise are easured at 20MHz of bandwidth by using a 12" twisted pair-wire ter inated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 35% Duty cycle axi u within every 10 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a co ponent which will be installed into a final equip ent. All the EMC tests are been executed by ounting the unit on
a * etal plate with 1 of thickness. The final equip ent ust be re-confir ed that it still eets EMC directives.720 360 For guidance on how to
perfor these EMC tests, please refer to EMI testing of co ponent power supplies. (as available on http://www. eanwell.co )
6. If the output voltage adjust to higher level, the rated current should be derated to eet the total rated power for both outputs(For MD-100 only).
7.The a bient te perature derating of 3.5 /1000 with fanless odels and of 5 /1000 with fan odels for operating altitude higher than 2000 (6500ft).℃℃