2.3 Electrical Specification Sheet
2
OUTPUT
INPUT
MODEL NO.
COOLING SYSTEM
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
VIBRATION
RATED INPUT VOLTAGE
MAX. CURRENT
CURRENT
RATED POWER
EFFICIENCY
VOLTAGE RANGE(UVW)
RATED INPUT CURRENT
SHORT CIRCUIT
PROTECTION
ENVIRONMENT
SWITCHING FREQUENCY
RANGE
OUTPUT
FREQUENCY
INVERTER PWM INPUT
AUXILIARY POWER VCC
FAULT SIGNAL
DC BUS VOLTAGE SENSOR
FUNCTION
THREE PHASE CURRENT
SENSOR
THERMAL SENSOR
SAFETY STANDARDS
SAFETY &
EMC
EMC IMMUNITY
EMC EMISSION
DIMENSION (L*W*H)
OTHERS PACKING
VFD-150P-48 VFD-250P-48 VFD-350P-48
Three phase 0~34V, suit for 48V class motorline-to-line
8.6A
150W
4.3A
93%
20 ~ 55VDC
3.5A /48VDC Typ.
Protection type : Shut down o/p voltage, re-power on to recover
2.5KHz ~ 15KHz
PWM control signal input for driving inverter IGBTs. (PIN8~13 of CN93)
IGBT ON: High(>2.6V); IGBT OFF: Low(<0.8V)TTL input :
Inverter fault signal(Short circuit/OCP, PIN7 of CN93).
TTL input: Normal: High(> V); Abnormal: Low(<0.5V)3
DC BUS voltage sensor output(HV+ sensor, PIN1 of CN9 V348): 2.5V@DC BUS
Built-in m low-side shunt resisor (each phase),6 (PIN4~6 of CN93)Ω
Non-isolated 15V output power for user’s application. Max current : 0.2A, Ripple:1V
Built-n 10 IGBTs operating temperature.K sensingNTC forΩ
(TSM2A103F34D1R (Thinking Electronic), 3PIN2 of CN9 )
Compliance to EN61800-3 C2
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, EN61000-2-4, EN60146-1-1, EN61000-2-1
Air convection
20 ~ 90% RH non-condensing
-30 ~ +70 (Refer to “Dreating Curve”)℃
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
Design refer to EN61800-5
101.6*50.8*28.6mm
0.09kg
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
14.4A
250W
7.2A
93%
5.6A /48VDC Typ.
20A
350W
10A
92.5%
8.5A /48VDC Typ.
0.09kg 0.1kg
DC Input PCB Type (for 48V Motor)
4
2
OUTPUT
MODEL NO.
CURRENT
POWER
VOLTAGE RANGE(UVW)
VFD-250P-230 VFD-350P-230
Three phase 0~ V, suit for V class motorline-to-line 240 200-240
250W
1A
350W
1.4A
INPUT
COOLING SYSTEM
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
VIBRATION
PEAK CURRENT
EFFICIENCY
SHORT CIRCUIT
PROTECTION
ENVIRONMENT
SWITCHING FREQUENCY RANGE
OUTPUT
FREQUENCY
INVERTER PWM INPUT
AUXILIARY POWER VCC
FAULT SIGNAL
DC BUS VOLTAGE SENSOR
FUNCTION
THREE PHASE CURRENT SENSOR
THERMAL SENSOR
SAFETY STANDARDS
SAFETY &
EMC
EMC IMMUNITY
EMC EMISSION
DIMENSION (L*W*H)
OTHERS PACKING
2A
91.5%
Air convection
20 ~ 90% RH non-condensing
-30 ~ +70 (Refer to “Dreating Curve”)℃
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
Design refer to EN61800-5
0.26kg
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
2.8A
93%
0.27kg
CONCECTION
15CFM
CONCECTION
15CFM
1.6A 2.2A
400W 550W
RATED INPUT VOLTAGE
DC BUS VOLTAGE
INPUT FREQUENCY RANGE (Hz)
POWER FACTOR (Typ.)
RATED INPUT CURRENT
INRUSH CURRENT
380 5VDC±
90 ~ 264VAC
47 ~ 63Hz
PF>0.99/115VAC, PF>0.93/230VAC
2.6A /115VAC 1.3A/230VAC
Cold start 70A
PWM control signal input for driving inverter IGBTs. (PIN8~13 of CN93)
IGBT ON: High(>2.6V); IGBT OFF: Low(<0.8V)TTL input :
Inverter fault signal(Short circuit/OCP, PIN7 of CN93).
TTL input: Normal: High(> V); Abnormal: Low(<0.5V)3
DC BUS voltage sensor output(HV+ sensor, PIN1 of CN93): 2.5V@DC BUS 380V
Protection type : Shut down o/p voltage, re-power on to recover
2.5KHz ~ 15KHz
Built-in 0m low-side shunt resisor (each phase),10 Ω(PIN4~6 of CN93)
Non-isolated 15V output power for user’s application. Max current : 0.1A, Ripple:1V
Built- n 10 NTC for IGBTs operating temperature.i K sensingΩ
(TSM2A103F34D1R (Thinking Electronic), PIN2 of CN93)
127*76.2*35mm
Compliance to EN61800-3 C2, BS EN/EN61000-3-2,-3
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, EN61000-2-4, EN60146-1-1, EN61000-2-1
I/P-FG:100M Ohms/500VDC/25 / 70%RH℃
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-FG:2KVAC
PF>0.99/115VAC, PF>0.93/230VAC
3.5A /115VAC 2A/230VAC
AC Input PCB Type (for 230V Motor)