manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Meanwell
  6. •
  7. Power Supply
  8. •
  9. Meanwell DR-15-12 User manual

Meanwell DR-15-12 User manual

Installation Manual
Type:DR Family with Class II(Series:DR-15, DR-30, DR-60, DR-100)
DR-15-5 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 5V 2.4A
DR-15-12 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 12V 1.25A
DR-15-15 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 15V 1A
DR-15-24 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 24V 0.63A
DR-30-5 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 5V 3A
DR-30-12 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 12V 2A
DR-30-15 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 15V 2A
DR-30-24 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 24V 1.5A
DR-60-5 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 5V 6.5A
DR-60-12 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 12V 4.5A
DR-60-15 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 15V 4A
DR-60-24 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 24V 2.5A
DR-100-12 INPUT: 100 -240VAC 3A 50/60Hz OUTPUT: 12V 7.5A
DR-100-15 INPUT: 100 -240VAC 3A 50/60Hz OUTPUT: 15V 6.5A
DR-100-24 INPUT: 100 -240VAC 3A 50/60Hz OUTPUT: 24V 4.2A
Introduction
DR with class II is a double insulated DIN rail power supply series, meaning it is ungrounded. Like other Mean Well’s
DIN series, they can be mounted on a TS35 Standard DIN rail.
Installation
(1)Always allow good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit
in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a
heat source.
(2)The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on
the top for DR-15, the input terminals on the right and output on the left for DR-30, DR-60, and DR-100.
Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not
allowed.
(3)Use stranded copper wire only, and recommended wires are shown as below.
AWG
18
16
14
12
Rated Current of
Equipment (Amp)
6A
6-10A
13-16A
16-25A
Cross-section of
Lead(mm2)
0.75
1.00
1.5
2.5
Note:Current each wire carries should be de-rated to 80% of the current suggested
above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please make
sure each contact is connected to wires to prevent too much current stress on a single contact.
1 DR15-100_1680-21407-0590-E-0418
Installation Manual
3
1
2
4
(4)Use wire that can withstand temperatures of at least 80°C such as UL1007.
(5)Recommended wire strapping length is 7mm/0.275inch.
(6)Recommended torque setting for terminals is 5 kgf-cm (4.4 Lb-in).
(7)Recommended screwdriver is 3mm, slotted type.
(8)Suggested fuse and maximum number of the DR classⅡPSUs that can be connected to a circuit breaker at
230V are shown as below.
Model
Fuse
Circuit breaker
C16
D16
DR-15
T2A/L250V
19
22
DR-30
F2A/L250V
7
15
DR-60
F3.15A/L250V
3
7
DR-100
F3.15A/L250V
3
6
(9)Mounting Instruction:
Mount as shown in figure only, with input terminals down, or else sufficient cooling will not be possible.
Admissible DIN rail:TS35/7.5 or TS35/15
For rail fastening:
(a)Tilt the unit slightly rearwards.
(b)Fit the unit over top hat rail.
(c)Slide it downward until it hits the stop.
(d)Press against the bottom for locking.
(e)Shake the unit slightly to check the locking action.
(10)For other information about the products, please refer to www.meanwell.com for details.
Warning / Caution !!
(1)Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
(2)Risk of electric arcs and electric shock (danger to life). Connecting both the primary and the secondary sides
together is not allowed.
(3)Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection!
(4)Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
(5)Only install the unit in a pollution degree 2 environment (Note.1).
(6)Please do not install the unit in places with high moisture or near the water.
(7)The maximum operating temperatures is 50°C for DR-15 and DR-30 series and 40°C for DR-60 and DR-100 series,
please do not install the unit in places with high ambient temperature or near fire source.
(8)Output current and output wattage must not exceed the rated values on its specification.
"Click"
2 DR15-100_1680-21407-0590-E-0418
Installation Manual
(9)Disconnect system from supply voltage:
Before commencing any installation, maintenance or modification work: Disconnect your system from supply
voltage. Make sure that inadvertent connection in circuit will be impossible!
(10)For continued protection against risk of fire, replace only with same type and rating of fuse.
Pour ne pas compromettre la protection contre les risqué d’incendie, remplacer par un fusible de même type
et de memes caractéristiques nominales.
Note.1: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become
conductive due to occasional condensation. Generally refer to dry, well-ventilated locations, such as
control cabinets.
3 DR15-100_1680-21407-0590-E-0418
Declaration of China RoHS Conformity
In order to reduce the impacts on the environment and take the more responsibility for protecting the
earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an
Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and
Electronic Products.
Environment Friendly Use Period Label
Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous
Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly
Use Period of Electronic Information ProductsAppendix B, adopting
table look-up to verify the Environment Friendly Use Period
Names and Contents of Hazardous Substances Lists
Part Name
Hazardous Substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr6+)
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
PCB and its
components
X
O
X
O
O
O
Metal structure
parts
X
O
O
O
O
O
Plastic structure
parts
O
O
O
O
O
O
Accessories
O
O
O
O
O
O
Cables
X
O
O
O
O
O
O: The concentration of the hazardous substances within the homogeneous material of that product is less than
the concentration limits set by GB/T 26572-2011.
X: The concentration of the hazardous substances within the homogeneous material of that product is over the
concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.
4 DR15-100_1680-21407-0590-E-0418
Experts on Design-In

for sensors and power solutions
Scan here and get an overview of personal contacts!
sensorsandpower.angst-pfister.com
We are here for you. Addresses and Contacts.
Headquarter Switzerland:
Angst+Pfister Sensors and Power AG
Thurgauerstrasse 66
CH-8050 Zurich
Phone +41 44 877 35 00
sensorsandpower@angst-pfister.com
Office Germany:
Angst+Pfister Sensors and Power Deutschland GmbH
Edisonstraße 16
D-85716 Unterschleißheim
Phone +49 89 374 288 87 00
sensorsandpower.de@angst-pfister.com

This manual suits for next models

14

Other Meanwell Power Supply manuals

Meanwell RST-7K5-HV Series User manual

Meanwell

Meanwell RST-7K5-HV Series User manual

Meanwell LCM-25 User manual

Meanwell

Meanwell LCM-25 User manual

Meanwell SDR Series User manual

Meanwell

Meanwell SDR Series User manual

Meanwell NMP650 User manual

Meanwell

Meanwell NMP650 User manual

Meanwell HEP-1000 User manual

Meanwell

Meanwell HEP-1000 User manual

Meanwell LCM-40(DA) User manual

Meanwell

Meanwell LCM-40(DA) User manual

Meanwell HLG-240H-15 User manual

Meanwell

Meanwell HLG-240H-15 User manual

Meanwell IRC1 User manual

Meanwell

Meanwell IRC1 User manual

Meanwell RKP-1U User manual

Meanwell

Meanwell RKP-1U User manual

Meanwell DDR-480B-12 User manual

Meanwell

Meanwell DDR-480B-12 User manual

Meanwell DR Series User manual

Meanwell

Meanwell DR Series User manual

Meanwell AP User manual

Meanwell

Meanwell AP User manual

Meanwell MP450 User manual

Meanwell

Meanwell MP450 User manual

Meanwell TDR-480-24 User manual

Meanwell

Meanwell TDR-480-24 User manual

Meanwell RKP-CMU1 User manual

Meanwell

Meanwell RKP-CMU1 User manual

Meanwell DDR-120A-12 User manual

Meanwell

Meanwell DDR-120A-12 User manual

Meanwell CSP Series User manual

Meanwell

Meanwell CSP Series User manual

Meanwell HEP-1000 User manual

Meanwell

Meanwell HEP-1000 User manual

Meanwell RSP-1000 Series User manual

Meanwell

Meanwell RSP-1000 Series User manual

Meanwell DDR-120 Series User manual

Meanwell

Meanwell DDR-120 Series User manual

Meanwell KNX-20E-640 User manual

Meanwell

Meanwell KNX-20E-640 User manual

Meanwell LAD Series User manual

Meanwell

Meanwell LAD Series User manual

Meanwell RCP-2000 User manual

Meanwell

Meanwell RCP-2000 User manual

Meanwell TDR-960 Series User manual

Meanwell

Meanwell TDR-960 Series User manual

Popular Power Supply manuals by other brands

Powdeom EV1200 user manual

Powdeom

Powdeom EV1200 user manual

Sky Factory 24PS HLG installation manual

Sky Factory

Sky Factory 24PS HLG installation manual

ROBBE RO-BEC instruction manual

ROBBE

ROBBE RO-BEC instruction manual

TekPower TP3016M Series user guide

TekPower

TekPower TP3016M Series user guide

limoss MD200 Service instruction

limoss

limoss MD200 Service instruction

Pulsar AWZ 300 quick start guide

Pulsar

Pulsar AWZ 300 quick start guide

Nemtek MERLIN II M Series user manual

Nemtek

Nemtek MERLIN II M Series user manual

EFLOW eFlow6N Series installation guide

EFLOW

EFLOW eFlow6N Series installation guide

Palmer PWT12MK2 user manual

Palmer

Palmer PWT12MK2 user manual

Western Co Leonardo Off-Grid GE Py user manual

Western Co

Western Co Leonardo Off-Grid GE Py user manual

TDK-Lambda ZWP350-1000 Series instruction manual

TDK-Lambda

TDK-Lambda ZWP350-1000 Series instruction manual

Sadelta SPS-2530D user manual

Sadelta

Sadelta SPS-2530D user manual

Musical Fidelity X-PSUV8 X-V8 Instructions for use

Musical Fidelity

Musical Fidelity X-PSUV8 X-V8 Instructions for use

Vertiv NetSure 700NVBA user manual

Vertiv

Vertiv NetSure 700NVBA user manual

Gewiss Chorus GW19301 manual

Gewiss

Gewiss Chorus GW19301 manual

Brooks Instrument 0260 quick start guide

Brooks Instrument

Brooks Instrument 0260 quick start guide

DMtex FP9000 P instruction manual

DMtex

DMtex FP9000 P instruction manual

Recom RACM40-05SK/OF Installation and operating instructions

Recom

Recom RACM40-05SK/OF Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.