Installation Manual
Type:MDR DIN rail power supply(Series:MDR-10, MDR-20, MDR-40, MDR-60, MDR-100)
MDR-10-5 INPUT: 100 -240VAC 0.33A 50/60Hz OUTPUT: 5V 2A
MDR-10-12 INPUT: 100 -240VAC 0.33A 50/60Hz OUTPUT: 12V 0.84A
MDR-10-15 INPUT: 100 -240VAC 0.33A 50/60Hz OUTPUT: 15V 0.67A
MDR-10-24 INPUT: 100 -240VAC 0.33A 50/60Hz OUTPUT: 24V 0.42A
MDR-20-5 INPUT: 100 -240VAC 0.55A 50/60Hz OUTPUT: 5V 3A
MDR-20-12 INPUT: 100 -240VAC 0.55A 50/60Hz OUTPUT: 12V 1.67A
MDR-20-15 INPUT: 100 -240VAC 0.55A 50/60Hz OUTPUT: 15V 1.34A
MDR-20-24 INPUT: 100 -240VAC 0.55A 50/60Hz OUTPUT: 24V 1A
MDR-40-5 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 5V 6A
MDR-40-12 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 12V 3.33A
MDR-40-24 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 24V 1.7A
MDR-40-48 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 48V 0.83A
MDR-60-5 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 5V 10A
MDR-60-12 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 12V 5A
MDR-60-24 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 24V 2.5A
MDR-60-48 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 48V 1.25A
MDR-100-12 INPUT: 100 -240VAC 1.3A 50/60Hz OUTPUT: 12V 7.5A
MDR-100-24 INPUT: 100 -240VAC 1.3A 50/60Hz OUTPUT: 24V 4A
MDR-100-48 INPUT: 100 -240VAC 1.3A 50/60Hz OUTPUT: 48V 2A
Introduction
MDR is a DIN rail power supply series with < 1W no load power consumption. And like other Mean Well’s DIN series,
they can be mounted on a TS35 Standard DIN rail.
Installation
(1)Always allow good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit
in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a
heat source.
(2)The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on
the top. Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not
allowed.
Installation Manual
3
1
2
4
(3)Use copper wire only, and recommended wires are shown as below.
AWG
18
16
14
12
Rated Current of
Equipment (Amp)
6A
6-10A
13-16A
16-25A
Cross-section of
Lead(mm2)
0.75
1.00
1.5
2.5
Note:Current each wire carries should be de-rated to 80% of the current suggested
above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please make
sure each contact is connected to wires to prevent too much current stress on a single contact.
(4)Use wires that can withstand temperatures of at least 80°C such as UL1007.
(5)Recommended wire strapping length is 6.5mm (0.255”).
(6)Recommended screwdriver is 3mm, slotted type.
(7)The recommended torque setting for terminals is 5 kgf-cm (4.4 Lb-in).
(8)Suggested fuse and maximum number of the MDR PSUs that can be connected to a circuit breaker at 230V are
shown as below.
Model
Fuse
Circuit breaker
C16
D16
MDR-10
T2A/L250V
11
22
MDR-20
T2A/L250V
9
18
MDR-40
T2.5A/L250V
6
13
MDR-60
T2.5A/L250V
4
9
MDR-100
T4A/L250V
10
13
(9)Mounting Instruction:
Mount as shown in figure only, with input terminals down, or else sufficient cooling will not be possible.
Admissible DIN rail:TS35/7.5 or TS35/15
For rail fastening:
(a)Tilt the unit slightly rearwards.
(b)Fit the unit over top hat rail.
(c)Slide it downward until it hits the stop.
(d)Press against the bottom for locking.
(e)Shake the unit slightly to check the locking action.
(10)For other information about the products, please refer to www.meanwell.com for details.
"Click"
Installation Manual
Warning / Caution !!
(1)Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
(2)Risk of electric arcs and electric shock (danger to life). Connecting both the primary and the secondary sides
together is not allowed.
(3)Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection!
(4)Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
(5)Only install the unit in a pollution degree 2 environment (Note.1).
(6)Please do not install the unit in places with high moisture or near the water.
(7)The maximum operating temperature is 35°C for MDR-100-12 and 40°C for MDR-100-24, MDR-100-48 and
50°C for MDR-10/20/40/60 series, please do not install the unit in places with high ambient temperature or
near fire source.
(8)The FG ( ) must be connected to PE (Protective Earth).
(9)Output current and output wattage must not exceed the rated values on its specification.
(10)Disconnect system from supply voltage:
Before commencing any installation, maintenance or modification work: Disconnect your system from
supply voltage. Make sure that inadvertent connection in circuit will be impossible!
(11)For continued protection against risk of fire, replace only with same type and rating of fuse.
Pour ne pas compromettre la protection contre les risqué d’incendie, remplacer par un fusible de même
type et de memes caractéristiques nominales.
Note.1: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become
conductive due to occasional condensation. Generally refer to dry, well-ventilated locations, such as
control cabinets.
Manufacturer:
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office:
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu
Declaration of China RoHS Conformity
In order to reduce the impacts on the environment and take the more responsibility for protecting the
earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an
Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and
Electronic Products.
Environment Friendly Use Period Label
Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous
Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly
Use Period of Electronic Information ProductsAppendix B, adopting
table look-up to verify the Environment Friendly Use Period
Names and Contents of Hazardous Substances Lists
Part Name
Hazardous Substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr6+)
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
PCB and its
components
X
O
X
O
O
O
Metal structure
parts
X
O
O
O
O
O
Plastic structure
parts
O
O
O
O
O
O
Accessories
O
O
O
O
O
O
Cables
X
O
O
O
O
O
O: The concentration of the hazardous substances within the homogeneous material of that product is less than
the concentration limits set by GB/T 26572-2011.
X: The concentration of the hazardous substances within the homogeneous material of that product is over the
concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.
Declaration of China VOC Conformity
In order to reduce the impacts on the environment and take the more responsibility
for protecting the earth, MEAN WELL is confirming and announcing the conformity to
China’s Standardization Administration Releases VOC Standards
Standard No. Name of the Standard
GB 30981-2020 Limit of harmful substances of industrial protective coatings
GB 33372-2020 Limits for volatile organic compounds content in adhesive
GB 38507-2020 Limits for volatile organic compounds (VOCs) In printing ink
GB 38508-2020 Limits for volatile organic compounds content in cleaning agents
Declaration of Five PBT TSCA Conformity
In order to reduce the impacts on the environment and take the more responsibility
for protecting the earth, MEAN WELL hereby confirms that MEAN WELL product
series comply with Use and Risk Management for Five PBT Chemicals under TSCA
section 6(h)
CAS No.
Substance Name
1163-19-5
Decabromodiphenyl ether (DecaBDE)
68937-41-7
Phenol, isopropylated, phosphate (3:1)
PIP (3:1)
732-26-3
2,4,6-Tris (tert-butyl) phenol (2,4,6-TTBP)
133-49-3
Pentachlorothiophenol (PCTP)
87-68-3
Hexachlorobutadiene (HCBD)

This manual suits for next models

24

Other Meanwell Power Supply manuals

Meanwell LCM-40(DA) User manual

Meanwell

Meanwell LCM-40(DA) User manual

Meanwell XLG-25 Series User manual

Meanwell

Meanwell XLG-25 Series User manual

Meanwell DDR-15G-3.3 User manual

Meanwell

Meanwell DDR-15G-3.3 User manual

Meanwell SHP-10K Series User manual

Meanwell

Meanwell SHP-10K Series User manual

Meanwell SDR Series User manual

Meanwell

Meanwell SDR Series User manual

Meanwell HDR-15 Series User manual

Meanwell

Meanwell HDR-15 Series User manual

Meanwell DRP-3200 Series User manual

Meanwell

Meanwell DRP-3200 Series User manual

Meanwell SHP-30K-HV Series User manual

Meanwell

Meanwell SHP-30K-HV Series User manual

Meanwell RCP-1000 Series User manual

Meanwell

Meanwell RCP-1000 Series User manual

Meanwell DR-RDN20 User manual

Meanwell

Meanwell DR-RDN20 User manual

Meanwell VFD Series User manual

Meanwell

Meanwell VFD Series User manual

Meanwell DRA-40 Series User manual

Meanwell

Meanwell DRA-40 Series User manual

Meanwell APV-25 User manual

Meanwell

Meanwell APV-25 User manual

Meanwell PWR-40-24 User manual

Meanwell

Meanwell PWR-40-24 User manual

Meanwell RKP-1U User manual

Meanwell

Meanwell RKP-1U User manual

Meanwell RCP-2000 User manual

Meanwell

Meanwell RCP-2000 User manual

Meanwell DR Series User manual

Meanwell

Meanwell DR Series User manual

Meanwell LCM-25 User manual

Meanwell

Meanwell LCM-25 User manual

Meanwell DDR-120A-12 User manual

Meanwell

Meanwell DDR-120A-12 User manual

Meanwell RCP Series User manual

Meanwell

Meanwell RCP Series User manual

Meanwell AP User manual

Meanwell

Meanwell AP User manual

Meanwell HEP-1000 User manual

Meanwell

Meanwell HEP-1000 User manual

Meanwell RST-7K5-HV Series User manual

Meanwell

Meanwell RST-7K5-HV Series User manual

Meanwell LAD Series User manual

Meanwell

Meanwell LAD Series User manual

Popular Power Supply manuals by other brands

Altronix ALTV615DC8ULCB installation instructions

Altronix

Altronix ALTV615DC8ULCB installation instructions

Cosel LGA50A instruction manual

Cosel

Cosel LGA50A instruction manual

Lenel LNL-300XA quick reference

Lenel

Lenel LNL-300XA quick reference

LEM IST ULTRASTAB user guide

LEM

LEM IST ULTRASTAB user guide

TDK-Lambda SWS-L Series instruction manual

TDK-Lambda

TDK-Lambda SWS-L Series instruction manual

Master PS12 quick start guide

Master

Master PS12 quick start guide

Gossen MetraWatt P500 operating instructions

Gossen MetraWatt

Gossen MetraWatt P500 operating instructions

Gallagher M6000i instructions

Gallagher

Gallagher M6000i instructions

Cobra Power Station 200W owner's manual

Cobra

Cobra Power Station 200W owner's manual

Sorensen DCR 10-80B instruction manual

Sorensen

Sorensen DCR 10-80B instruction manual

VOLTCRAFT PLC-2400C operating instructions

VOLTCRAFT

VOLTCRAFT PLC-2400C operating instructions

ENFORCER SB-P1012-26Q manual

ENFORCER

ENFORCER SB-P1012-26Q manual

Antec VP450F user manual

Antec

Antec VP450F user manual

Unitek UNIBOND 2 user manual

Unitek

Unitek UNIBOND 2 user manual

CCR 400 manual

CCR

CCR 400 manual

GW Instek ASR-2000 Series manual

GW Instek

GW Instek ASR-2000 Series manual

Pulsar BLACK POWER PSBEN 2012C/LCD manual

Pulsar

Pulsar BLACK POWER PSBEN 2012C/LCD manual

Stafix M 0.5 user manual

Stafix

Stafix M 0.5 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.