Meanwell DRH-120 Series User manual

Installation Manual
Type:General Type DIN rail with Three Phase or High Input Range
(Series:DRH-120, DRT-240, DRT-480, DRT-960)
DRH-120-24 INPUT: 400 -500VAC 0.65A 50/60Hz OUTPUT: 24V 5A
DRH-120-48 INPUT: 400 -500VAC 0.65A 50/60Hz OUTPUT: 48V 2.5A
DRT-240-24 INPUT: 400 -500VAC 0.95A 50/60Hz OUTPUT: 24V 10A
DRT-240-48 INPUT: 400 -500VAC 0.95A 50/60Hz OUTPUT: 48V 5A
DRT-480-24 INPUT: 400 -500VAC 1.7A 50/60Hz OUTPUT: 24V 20A
DRT-480-48 INPUT: 400 -500VAC 1.7A 50/60Hz OUTPUT: 48V 10A
DRT-960-24 INPUT: 400 -500VAC 2.4A 50/60Hz OUTPUT: 24V 40A
DRT-960-48 INPUT: 400 -500VAC 2.4A 50/60Hz OUTPUT: 24V 20A
Introduction
General type with three phase or high input range is a DIN rail power supply series with a high input range,
340-550Vac. Like other Mean Well’s DIN series, they can be mounted on a TS35 Standard DIN rail.
Installation
(1)Always allow good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit
in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a
heat source.
(2)The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on
the top for DRH-120, the input terminals on the right and output on the left for DRT-240, DRT-480 and
DRT-960. Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is
not allowed.
(3)Use copper wire only, and recommended wires are shown as below.
AWG
18
16
14
12
10
Rated Current of
Equipment (Amp)
6A
6-10A
13-16A
16-25A
25-32A
Cross-section of
Lead(mm2)
0.75
1.00
1.5
2.5
4
Note: Current each wire carries should be de-rated to 80% of the current suggested
above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please make
sure each contact is connected to wires to prevent too much current stress on a single contact.
(4)Use wires that can withstand temperatures of at least 80°C such as UL1007.
(5)Recommended wire strapping length is 5mm (0.197”).
(6)Recommended screwdriver is 4mm, slotted type.
(7)The recommended torque setting for terminals is 10 kgf-cm (9 Lb-in).
Installation Manual
3
1
2
4
L1
L2
L3
N
PE
AC/L2
AC/L1
FG
AC
DC
(8)Suggested fuse and maximum number of the PSUs that can be connected to a circuit breaker at 230V are
shown as below.
Model
Fuse
Circuit breaker
C16
D16
DRH-120
T4A/H250V
14
16
DRT-240
F3A/L250V
8
10
DRT-480
F6.3A/L250V
3
5
DRT-960
F6.3A/L250V
2
4
When an external circuit breaker is utilised, a minimum value is required to avoid undesired tripping of the
circuit breaker.
(9)For DRH-120 series, it is capable of being connected between any 2 phases on a 3-phase-4-wire Wye (Star)
connected system.
Using a fuse or a circuit break to protect the AC/L2 input is suggested. The AC/L2 input is internally
non-protected.
(10)For DRT-240, DRT-480, and DRT-960 series, they are capable of dual phase operation (connecting L1, L3, FG
for DRT-960), but that requires de-rating output current by 20%.
(11)Mounting Instruction:
Mount as shown in figure only, with input terminals down, or else sufficient cooling will not be possible.
Admissible DIN rail:TS35/7.5 or TS35/15
For rail fastening:
(a)Tilt the unit slightly rearwards.
(b)Fit the unit over top hat rail.
(c)Slide it downward until it hits the stop.
(d)Press against the bottom for locking.
(e)Shake the unit slightly to check the locking action.
(12)Electrical Tubing and sleeve –Recognized Component –Tubing (YDPU2) and/or sleeving (UZFT2), rated 300V,
105℃minimum.
(13)For other information about the products, please refer to www.meanwell.com for details.
"Click"
Installation Manual
Warning / Caution !!
(1)Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
(2)Risk of electric arcs and electric shock (danger to life). Connecting both the primary and the secondary sides
together is not allowed.
(3)Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection!
(4)Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
(5)Only install the unit in a pollution degree 2 environment (Note.1).
(6)Please do not install the unit in places with high moisture or near the water.
(7)The maximum operating temperature is 40°C for DRT-240 and DRT-480 series, 50°C for DRH-120 series and
DRT-960 series, please do not install the unit in places with high ambient temperature or near fire source.
(8)The FG ( ) must be connected to PE (Protective Earth).
(9)Output current and output wattage must not exceed the rated values on its specification.
(10)Disconnect system from supply voltage:
Before commencing any installation, maintenance or modification work: Disconnect your system from
supply voltage. Make sure that inadvertent connection in circuit will be impossible!
(11)For continued protection against risk of fire, replace only with same type and rating of fuse.
Pour ne pas compromettre la protection contre les risqué d’incendie, remplacer par un fusible de même
type et de memes caractéristiques nominales.
Note.1: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become
conductive due to occasional condensation. Generally refer to dry, well-ventilated locations, such as
control cabinets.
Manufacturer:
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office:
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu
Declaration of China RoHS Conformity
In order to reduce the impacts on the environment and take the more responsibility for protecting the
earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an
Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and
Electronic Products.
Environment Friendly Use Period Label
Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous
Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly
Use Period of Electronic Information ProductsAppendix B, adopting
table look-up to verify the Environment Friendly Use Period
Names and Contents of Hazardous Substances Lists
Part Name
Hazardous Substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr6+)
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
PCB and its
components
X
O
X
O
O
O
Metal structure
parts
X
O
O
O
O
O
Plastic structure
parts
O
O
O
O
O
O
Accessories
O
O
O
O
O
O
Cables
X
O
O
O
O
O
O: The concentration of the hazardous substances within the homogeneous material of that product is less than
the concentration limits set by GB/T 26572-2011.
X: The concentration of the hazardous substances within the homogeneous material of that product is over the
concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.
Declaration of China VOC Conformity
In order to reduce the impacts on the environment and take the more responsibility
for protecting the earth, MEAN WELL is confirming and announcing the conformity to
China’s Standardization Administration Releases VOC Standards
Standard No. Name of the Standard
GB 30981-2020 Limit of harmful substances of industrial protective coatings
GB 33372-2020 Limits for volatile organic compounds content in adhesive
GB 38507-2020 Limits for volatile organic compounds (VOCs) In printing ink
GB 38508-2020 Limits for volatile organic compounds content in cleaning agents
Declaration of Five PBT TSCA Conformity
In order to reduce the impacts on the environment and take the more responsibility
for protecting the earth, MEAN WELL hereby confirms that MEAN WELL product
series comply with Use and Risk Management for Five PBT Chemicals under TSCA
section 6(h)
CAS No.
Substance Name
1163-19-5
Decabromodiphenyl ether (DecaBDE)
68937-41-7
Phenol, isopropylated, phosphate (3:1)
PIP (3:1)
732-26-3
2,4,6-Tris (tert-butyl) phenol (2,4,6-TTBP)
133-49-3
Pentachlorothiophenol (PCTP)
87-68-3
Hexachlorobutadiene (HCBD)

This manual suits for next models

11

Other Meanwell Power Supply manuals

Meanwell RSP-1000 Series User manual

Meanwell

Meanwell RSP-1000 Series User manual

Meanwell MP450 User manual

Meanwell

Meanwell MP450 User manual

Meanwell RCB-1600 Series User manual

Meanwell

Meanwell RCB-1600 Series User manual

Meanwell CSP Series User manual

Meanwell

Meanwell CSP Series User manual

Meanwell DRA Series User manual

Meanwell

Meanwell DRA Series User manual

Meanwell DRA-40 Series User manual

Meanwell

Meanwell DRA-40 Series User manual

Meanwell HEP-1000 User manual

Meanwell

Meanwell HEP-1000 User manual

Meanwell RKP-1U-CMU1 User manual

Meanwell

Meanwell RKP-1U-CMU1 User manual

Meanwell TDR-240-24 User manual

Meanwell

Meanwell TDR-240-24 User manual

Meanwell XLG-25 Series User manual

Meanwell

Meanwell XLG-25 Series User manual

Meanwell DRDN20 User manual

Meanwell

Meanwell DRDN20 User manual

Meanwell ELG-150-C Series User manual

Meanwell

Meanwell ELG-150-C Series User manual

Meanwell SDR Series User manual

Meanwell

Meanwell SDR Series User manual

Meanwell WDR Series User manual

Meanwell

Meanwell WDR Series User manual

Meanwell SHP-30K-HV Series User manual

Meanwell

Meanwell SHP-30K-HV Series User manual

Meanwell EDR-75-12 User manual

Meanwell

Meanwell EDR-75-12 User manual

Meanwell KNX-20E-640 User manual

Meanwell

Meanwell KNX-20E-640 User manual

Meanwell SHP-10K Series User manual

Meanwell

Meanwell SHP-10K Series User manual

Meanwell ICL-16L Series User manual

Meanwell

Meanwell ICL-16L Series User manual

Meanwell KNX-40E-1280D User manual

Meanwell

Meanwell KNX-40E-1280D User manual

Meanwell LCM-25KM User manual

Meanwell

Meanwell LCM-25KM User manual

Meanwell DR-15-12 User manual

Meanwell

Meanwell DR-15-12 User manual

Meanwell DRP-3200 Series User manual

Meanwell

Meanwell DRP-3200 Series User manual

Meanwell RCP-2000 User manual

Meanwell

Meanwell RCP-2000 User manual

Popular Power Supply manuals by other brands

National Instruments PXIe-4135 CALIBRATION PROCEDURE

National Instruments

National Instruments PXIe-4135 CALIBRATION PROCEDURE

Insignia NS-PCW4050 user guide

Insignia

Insignia NS-PCW4050 user guide

nextys NPST721 Series instruction manual

nextys

nextys NPST721 Series instruction manual

Black Box PS568A user manual

Black Box

Black Box PS568A user manual

HP 59501A Operating and service manual

HP

HP 59501A Operating and service manual

Alarmtech PSV 2435-12 instruction manual

Alarmtech

Alarmtech PSV 2435-12 instruction manual

EDF PPS500D user manual

EDF

EDF PPS500D user manual

Puls QS20.481 instruction manual

Puls

Puls QS20.481 instruction manual

PDi PDI-750 installation instructions

PDi

PDi PDI-750 installation instructions

GE Tetra Series installation guide

GE

GE Tetra Series installation guide

Puls DIMENSION QS5-Series instruction manual

Puls

Puls DIMENSION QS5-Series instruction manual

Altronix Maximal1RD installation guide

Altronix

Altronix Maximal1RD installation guide

VOLTCRAFT PLC-2400C operating instructions

VOLTCRAFT

VOLTCRAFT PLC-2400C operating instructions

Pulsar Black Power PSBEN 2024C/LCD instructions

Pulsar

Pulsar Black Power PSBEN 2024C/LCD instructions

IBM S822L installation manual

IBM

IBM S822L installation manual

Asus ROG STRIX Q15428 quick start guide

Asus

Asus ROG STRIX Q15428 quick start guide

Spondoolies tech SP20 Jackson quick start guide

Spondoolies tech

Spondoolies tech SP20 Jackson quick start guide

KTI Networks KPW-1012-D user manual

KTI Networks

KTI Networks KPW-1012-D user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.