3
2. 3 Electrical Specification
DRS-240 Series
480mVp-p
48V
92%
41 1V±.8
DRS-240-48
0 ~ 5A
105 ~ 135% rated output power
MODEL
OUTPUT VOLTAGE Note.2
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.7
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
BATTERY CUT OFF
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OPERATING ALTITUDE
Note.8
OVER VOLTAGE CATEGORY
DIMENSION
OTHERS
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
2400ms, 1000ms/230VAC 2400ms, 1000ms/115VAC at full load
90 ~ 127 ~ 431VDC305VAC
COLD START 30A/115VAC 60A/230VAC
-30 ~ +70 (Refer to “Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃ ℃)0.03%/ (0 ~ 50 on Load output
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
2000 meters / OVC Ⅲ
Ⅲ; According to Dekra BS EN/EN62368-1; altitude up to 2000 meters
564.7K hrs min. Telcordia SR-332 (Bellcore); 73.3K hrs min. MIL-HDBK-217F (25 )℃
PF>0.95/230VAC PF>0.98/115VAC at full load
16ms/230VAC 10ms/115VAC at full load
VOLTAGE TOLERANCE
Note.6
ENVIRONMENT
PROTECTION
85.5*125.2*129.2mm (W*H*D)
Protection type : Shut down o/p voltage, re-power on to recover
2.8A/115VAC 1.4A/230VAC
CURRENT RANGE
TOTAL OUTPUT POWER
Note.4
RIPPLE & NOISE (max.)
Note.5
47 ~ 63Hz
Protection type: Constant current limiting, shutdown output voltage after 5 sec.
FUNCTION
AC FAIL
BATTERY LOW/
ABNORMAL/
DISCONNECTED
Relay contact output, ON : Battery OK ; OFF : Battery Low ; max. rating : 30Vdc/1A
Battery low voltage:< 11 0.2V±Battery low voltage:< 33±0.4V Battery low voltage:< 44 0.5V±
±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5%
±1.0% ±1.0% ±1.0%
Load main output : 16.2 ~ 18.6V
MTBF
PACKING
150mVp-p 360mVp-p
90% 92%
10 5 0.3V±. 31.3 0.7V±
DRS-240-12 DRS-240-36
12V 36V
0 ~ 20A 0 ~ 6.6A
DC OK
CHARGER FAIL
Signals normal DC output and activates when output voltage > 90% rated value.
Relay contact output, ON : DC OK ; OFF : DC Fail ; max. rating : 30Vdc/1A
Relay contact output, ON : Charger OK ; OFF : Charger Fail ; max. rating : 30Vdc/1A
REVERSE POLARITY
FORM-C
RELAY
DC-UPS
ADJUSTABLE CHARGING CURRENT
UPS switch to battery power within 10ms of AC failure
By internal MOSFET, , recovers automatically after fault condition is removed.no damage
BATTERY START Restart system directly from battery and does not require AC power
RECOMMENDED BATTERY
CAPACITY(AMP HOURS)Note.3
20 ~ 200AH 6.6 ~ 66AH 5 ~ 50AH
OVER TEMPERATURE
Battery low voltage:< 22 0.3V±
±0.5%
±0.5%
±1.0%
240mVp-p
92%
20 9 0.5V±.
DRS-240-24
24V
0 ~ 10A
10 ~ 100AH
BATTERY CURRENT (CC)(max.)
3.85A
15.4A 7.7A 5.1A
Load main output : 32.4 ~ 37.3V Load main output : 48.6 ~ 55.9V Load main output : 64.8 ~ 74.5V
Signals AC failure and activates when input voltage drops below : 79~89VAC of 120AC, 132~187VAC of 220VAC.
Relay contact output, ON : AC OK ; OFF : AC Fail ; max. rating : 30Vdc/1A
1.19Kg; 8pcs/ 12.5Kg / 1.08CUFT
20% ~ 100% charging current adjustable by VR
Automatically drop load with temperature only for bat. load.
Protection type : Shut down o/p voltage, .recover automatically after temperature goes down
SHORT CIRCUIT Protection type: Constant current limiting, power will shutdown after 5 sec, re-power on to recover.
Combined power on all Channels must not exceed 240W, load has priority. 275W peak capability within 5s.
2
4
DRS-480 Series
480mVp-p
48V
93.5%
41.8 1V±
DRS-480-48
0 ~ 10A
105 ~ 135% rated output power
MODEL
OUTPUT VOLTAGE
Note.2
OUTPUT
LINE REGULATION
LOAD REGULATION
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
BATTERY CUT OFF
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OPERATING ALTITUDE Note.8
OVER VOLTAGE CATEGORY
DIMENSION
OTHERS
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
90 ~ 127 ~ 431VDC305VAC
COLD START 30A/115VAC 60A/230VAC
-30 ~ +70 (Refer to “Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃ ℃)0.03%/ (0 ~ 50 on Load output
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
2000 meters / OVCⅢ
Ⅲ; According to Dekra BS EN/EN62368-1; altitude up to 2000 meters
556.6K hrs min. Telcordia SR-332 (Bellcore); 74.5K hrs min. MIL-HDBK-217F (25 )℃
PF>0.95/230VAC PF>0.98/115VAC at full load
16ms/230VAC 10ms/115VAC at full load
VOLTAGE TOLERANCE
Note.6
ENVIRONMENT
PROTECTION
110*125.2*150.7mm (W*H*D)
Protection type : Shut down o/p voltage, re-power on to recover
5.4A/115VAC 2.7A/230VAC
LOAD CURRENT RANGE
TOTAL OUTPUT POWER
Note.4
RIPPLE & NOISE (max.)
Note.5
1.65Kg; 6pcs/ 11Kg / 1.42CUFT
47 ~ 63Hz
Protection type: Constant current limiting, shutdown output voltage after 5 sec.
FUNCTION
AC FAIL
BATTERY LOW/
ABNORMAL/
DISCONNECTED
Signals AC failure and activates when input voltage drops below : 79~89VAC of 120AC, 132~187VAC of 220VAC.
Relay contact output, ON : AC OK ; OFF : AC Fail ; max. rating : 30Vdc/1A
Relay contact output, ON : Battery OK ; OFF : Battery Low ; max. rating : 30Vdc/1A
Battery low voltage : < 22V 0.3V±Battery low voltage : < 33V±0.4V Battery low voltage : < 44V 0.5V±
±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5%
±1.0% ±1.0% ±1.0%
Load main output : 32.4 ~ 37.3V Load main output : 48.6 ~ 55.9V Load main output : 64.8 ~ 74.5V
Combined power on all Channels must not exceed 480W, load has priority. 550W peak capability within 5s.
MTBF
PACKING
240mVp-p 360mVp-p
92.5% 93.5%
20.9 0.5V±31.3 0.7V±
DRS-480-24 DRS-480-36
24V 36V
0 ~ 20A 0 ~ 13.3A
DC OK
CHARGER FAIL
Signals normal DC output and activates when output voltage > 90% rated value.
Relay contact output, ON : DC OK ; OFF : DC Fail ; max. rating : 30Vdc/1A
Relay contact output, ON : Charger OK ; OFF : Charger Fail ; max. rating : 30Vdc/1A
REVERSE POLARITY
FORM-C
RELAY
DC-UPS
ADJUSTABLE CHARGING CURRENT
UPS switch to battery power within 10ms of AC failure
20% ~ 100% charging current adjustable by VR
By internal MOSFET, , recovers automatically after fault condition is removed.no damage
BATTERY START Restart system directly from battery and does not require AC power
RECOMMENDED BATTERY
CAPACITY(AMP HOURS)
Note.3
20 ~ 200AH 13 ~ 133AH 10 ~ 100AH
OVER TEMPERATURE Automatically drop load with temperature only for bat. load.
Protection type : Shut down o/p voltage, .recover automatically after temperature goes down
BATTERY CURRENT (CC)(max.)
7.7A
15.4A 10.2A
SETUP RISETIME
Note.7
2400ms, 1000ms/230VAC 2400ms, 1000ms/115VAC at full load
SHORT CIRCUIT Protection type: Constant current limiting, power will shutdown after 5 sec, re-power on to recover.
2