Mecon mag-flux HTL User manual

mag-ux HTL
Portable hydrant tester for measuring ow,
pressure, temperature* and turbidity*
*optional
OPERATING INSTRUCTIONS
© MECON GmbH BA / mag-flux HTL / EN / 21-04

2© MECON GmbH BA / mag-ux HTL / EN / 21-04
IMPRINT
All rights reserved. Any reproduction or usage without written authorisation of MECON
GmbH - even partial content - is strictly prohibited.
Subject to change without notice.
Copyright 2021 by MECON GmbH - Röntgenstr. 105 - 50169 Kerpen - Germany

3
© MECON GmbH BA / mag-ux HTL / EN / 21-04

4© MECON GmbH BA / mag-ux HTL / EN / 21-04
Content
..............................................................................................
1.1 Intended use.......................................................................................................................6
......................................................................................................................7
1.3 Manufacturer’s safety instructions ...............................................................................7
.................................................................................................
2.1 Scope of delivery ...............................................................................................................9
2.2 Nameplate...........................................................................................................................10
.............................................................
3.1 System design....................................................................................................................11
3.2 Installation notes...............................................................................................................11
3.3 Installation instructions ...................................................................................................11
3.4 Operating elements - functional overview ..................................................................12
3.5 Settings................................................................................................................................14
3.5.1 Save interval .......................................................................................................................14
3.5.2 Memory management.......................................................................................................15
3.5.3 Date ......................................................................................................................................15
3.5.4 Illumination time ................................................................................................................16
3.5.5 Change Password..............................................................................................................16
3.5.6 Standby................................................................................................................................16
3.5.7 Language.............................................................................................................................17
3.5.8 Software version................................................................................................................17
......................................................................................................................
4.1 Start measurement...........................................................................................................17
4.2 Start measurement with save ........................................................................................18
4.3 Start measurement with save (optionally with GPS coordinates) ..........................19
4.4 Selecting Bluetooth Mode ..............................................................................................20
4.4 Read data ............................................................................................................................21
.........................................................................................................
5.1 Flow meter...........................................................................................................................22
5.2 Pressure sensor .................................................................................................................22
5.3 Temperature sensor..........................................................................................................22
5.4 Turbidity sensor (seperate device).................................................................................23
5.5 Medium conditions............................................................................................................23

5
© MECON GmbH BA / mag-ux HTL / EN / 21-04
5.6 Design / material ...............................................................................................................23
5.7 Power supply ......................................................................................................................24
5.7 Dimensions and weights..................................................................................................24
...................................................................................................................
6.1 Mobile App...........................................................................................................................25
6.2 Regulating valve.................................................................................................................26
6.3 Pressure reducer ...............................................................................................................26
6.4 Turbidity sensor..................................................................................................................27
....................................................................................................
7.1 Hydrant tester ....................................................................................................................28
7.2 Regulating valve.................................................................................................................28
7.3 Pressure reducer ...............................................................................................................28
7.4 Turbidity sensor..................................................................................................................28
.........................................................................................................................
8.1 Storage ................................................................................................................................29
8.2 Maintenance .......................................................................................................................29
8.3 Returning the device to the manufacturer..................................................................29
8.4 Disposal ...............................................................................................................................30

6© MECON GmbH BA / mag-ux HTL / EN / 21-04
SAFETY INSTRUCTIONS
1
1.1 Intended use
-
transmitter.
and understood these operating instructions and follow the instructions within them!
Warning!
The operator of these measuring devices is solely responsible for the suit-
ability, intended use and corrosion resistance of the selected materials.
Particular eort must be made to ensure that the materials selected for
the wetted parts of the ow meter are suitable for the process media to be
measured.
The meter must not be exposed to external loads.

7
© MECON GmbH BA / mag-ux HTL / EN / 21-04
SAFETY INSTRUCTIONS
1.2
tester is approved according to the following guidelines:
»2014/30/EU (EMC)
»2014/53/EU (RED)
1.3
-
ages.
according to the relevant product documentation and the valid terms and conditions.
of such changes.
rests solely with the operator. MECON GmbH assumes no liability for any damage caused
-
In case of a complaint the rejected components must be cleaned of hazardous substanc-
es and to be returned to the manufacturer unless otherwise agreed.
-
ating instructions carefully before starting to use the device.
-

8© MECON GmbH BA / mag-ux HTL / EN / 21-04
SAFETY INSTRUCTIONS
Special designs for special applications and custom models are not covered by this
documentation.

9
© MECON GmbH BA / mag-ux HTL / EN / 21-04
DEVICE DESCRIPTION
2
2.1
Hydrant tester
Power adapter
Operating instructions
Fig. 1 Scope of delivery

10 © MECON GmbH BA / mag-ux HTL / EN / 21-04
DEVICE DESCRIPTION
Item number
Fig. 2 Nameplate mag-ux HTL
2.2
Downloading this document from the homepage of www.mecon.de and printing it out is
permitted for use with associated devices. No part of this manual may be reproduced or
-
other than that described in this manual.
We reserve the right to change technical data as a result of technological progress. The
latest information on this product can be found on the internet at www.mecon. You can

11
© MECON GmbH BA / mag-ux HTL / EN / 21-04
INSTALLATION AND MODE OF OPERATION
3
The operating instructions are to be read in their entirety before installation and com-
missioning. Installation and repair may only be carried out by trained personnel! The
-
The pressure-sensitive element is a piezoresistive silicon chip with high sensitivity. It is
3.1
caused by mechanical stress on the encapsulated sensor.
3.2
handling.

12 © MECON GmbH BA / mag-ux HTL / EN / 21-04
INSTALLATION AND MODE OF OPERATION
3.3
behind the measuring point. An inlet section of 5 x nominal width and an outlet section of
-
3.4
ON button
»
»
BT button
»
»Arrow down
OFF / Enter button
»
»
»
Pairing code for the 1st Bluetooth connection: -1234-

13
© MECON GmbH BA / mag-ux HTL / EN / 21-04
INSTALLATION AND MODE OF OPERATION
To turn on the hydrant tester press the "ON button" button. The start-up screen will appear
schematically as follows:
Start measurement
Settings
Turbidity
Save measurement
Measurement without saving
Save interval
Memory management
Date
Time
Lighting time
Change Password
Standby
Language
Software version
Turbidity enabled
Bluetooth Mode
29.03.21 15:15
Serial number: 134669
Flow direction
HTL

14 © MECON GmbH BA / mag-ux HTL / EN / 21-04
INSTALLATION AND MODE OF OPERATION
Start measurement
Settings
→ Turbidity
Bluetooth Mode
Back
Start measurement
→ Settings
Turbidity
Back
Save interval
Memory management
Date
Time
Lighting time
Change Password
Standby
Language
Software version
Back
Save interval
hh mm ss
00 00 01
→
before starting the measurement it should
be determined whether this value should
be documented or not. If these data are
present.
Enter button".
minutes: seconds).
A storage interval of 1 second is set in the
as-delivered condition.

15
© MECON GmbH BA / mag-ux HTL / EN / 21-04
INSTALLATION AND MODE OF OPERATION
Delete last record
Delete all records
Back
Date
29.03.21
Time
15:09:19
Delete "123456789"?
No
→ →
memory space used for this can be released again. All measured values are retained in the
Factory set already!
Factory set already!
Time

16 © MECON GmbH BA / mag-ux HTL / EN / 21-04
INSTALLATION AND MODE OF OPERATION
can be set in seconds.
0 = steady light
The duration can be set individually in
-
Factory set to 60 seconds!
after a measurement is completed. A time
automatically.
adjacent screen will appear. To protect the
protection is active.
the menu (only if this parameter was activated in the menu item "Change password").
Lighting time
From 0 to 240 seconds
60
Standby
From 0 to 180
60
Should the password be activated?
No

17
© MECON GmbH BA / mag-ux HTL / EN / 21-04
4
4.1
The device is switched on with the "ON button". Press the "ON button" again to return to
the main menu.
this menu item.
The current software version is displayed
here for service purposes.
The next menu item is selected using the
English (GB)
German (DE)
French (FR)
Italian (IT)
Back
Software version
3.1.0
→
→ Start measurement
Settings
Turbidity
Bluetooth Mode
Back

18 © MECON GmbH BA / mag-ux HTL / EN / 21-04
-
pears:
When measuring with data storage in
the device (and the possibility of subse-
must be made:
The following display appears for the
alphanumeric description of the measuring
point:
displayed (maximum 15 characters):
Letters: A … Z / a … z
Numbers: 0 … 9
Special characters: _ : ( ) + -
This allows the measured values to be assigned to a measuring point description.
measurement is made with the measuring point and the associated data being stored on
the device or a measurement without storage of the data.
4.2
→
→
Save measurement
Measurement without saving
Back
Save measurement
Measurement without saving
Back
Description
A

19
© MECON GmbH BA / mag-ux HTL / EN / 21-04
following appears:
following appears:
display.
→
Should the measurement be stopped?
Yes
29.03.21 15:07 REC
0.09
0.00
m³/h
bar
Total 0.00 m³
and the start screen appears.
4.3
Start measurement
Settings
Turbidity
Bluetooth Mode
Back
main menu item "Turbidity" and press the

20 © MECON GmbH BA / mag-ux HTL / EN / 21-04
The following contents then appear on the
display
/ ENTER" in the menu item "Turbidity".
Turbidity
Turbidity
Turbidity: enabled
Back
Turbidity: enabled
Back
>
>
as described in 4.1 and 4.2.
4.4
By pressing the menu item "Bluetooth
-
iants BT (Bluetooth) and BLE (Bluetooth
Low Energy).
The following settings are recommended
depending on the operating system of the
BT - Android
BLE - IOS
You can then return to the main menu via
Bluetooth Mode
Bluetooth Mode: BT
Back
>
Bluetooth Mode
Bluetooth Mode: BLE
Back
>
This manual suits for next models
6