MEET Technology MS-911 User manual

Mini Sound Meter With Temperature
①Windscreen microphone cover
②LCD display
③Hold button
④Power ON/OFF button
⑤MAX/MIN button
⑥Fast/ Slow selection button
⑥Battery compartment
Model No.: MS-911
Thank you for purchasing MEET Mini sound Meter
1. Contents
2. Descriptions
3. Advanced Features
5. Descriptions
Display 4 digits color LCD display
Measuring level range 35dB~135dB
Accuracy
-20ºC ~ 70ºC / 4ºF ~ 158ºF
±1.5ºC / 2.7ºF
Range (Temp.)
Accuracy (Temp.)
Resolution 0.1
Operating Condition
Storage Condition
Battery Powered / Battery Life
-20ºC ~ 60ºC / -4ºF ~ 140ºF; 10% RH ~ 90% RH
-30ºC ~ 60ºC / -4ºF ~ 140ºF; 10% RH ~ 75% RH
3 x AAA (R03 / LR03) / > 60 hours
Demensions (L x W x D) mm
(approx.) 145x57x31
Weight (approx.) grams
1
2
3
4
5
6
7
HOLD
21
75
Enable / Disable Auto power off The meter shuts off automatically after 15 minutes inactivity
under auto power off mode, disable auto power off is available
Data update 0.3s
Dynamic range 50dB
Frequency range 31.5Hz~8KHz
±2.0dB
Frequency weighting A frequency weighting
Time weighting
Microphone
FAST : 125ms / SLOW : 1s
1/2 inch electrets condenser microphone
High / low reading indication >100dB, LCD displays “Hi” ; <100dB,LCD displays “LO”
Applied Standard IEC61672-1 CLASS2
4. Specifications
This unit use condenser microphone as the sensor, high configuration MCU calculation, high
accuracy, fast response. This Sound Level Meter is designed to meet the measuremet requirements
of safety engineers, health, industrial safety offices and sound quality control in various environments
like factory, school, construction sites, etc.
- Sound meter
- Operating manual
- High accuracy, fast response
- Temperature measurement
- Wide frequency range
- Color LCD display with backlight
- Fast / slow time weighting
- Over range indication
- MAX / MIN record reading
- Enable / Disable auto power off (APO)
- Low battery indication
- Hold / Freeze reading

A) Power ON / OFF function
Power On / Off, press “ ” to turn on / off the meter. Backlit will be on once meter is power on.
B) Data Hold : In measuring mode, press “ ”, “HOLD” icon will appear on the LCD, which indicates
the data is freezed, to release the held reading, press “ ” again.
C) ‘MAX/MIN’ : in measuring mode, press “ ”, “MAX” will appear on the LCD, the captured maximum
sound level will be displayed on the LCD, press “ ” again, “MIN” will appear on the LCD and the
captured minimum sound level will be displayed on the LCD. Long press “ ”, the meter exit MAX/MIN
measurement mode and back to normal measuring mode.
D) ‘ ’button: with the meter on, press “ ” to select FAST (125mS) or slow(1s) time weighting measurement.
FAST : Fast sampling measurement,1 time per 125ms.
SLOW : Slow sampling measurement, 1 time per second
E) Use of compound button
i) With the meter off, first press and hold “ ” then press “ ” to turn on the meter. It can change
temperature unit (ºC/ºF), ºC is preset.
ii) With the meter off, first press and hold “ ” then press “ ” to turn on the meter. “ ” icon on the
LCD disappears which indicates the ‘auto power off ’ function is disabled, you need to turn off the
meter through pressing “ ” by manual.
Note : When“ ”icon displayed on the screen, it indicates that the meter will automatically turn off after
approx.15 minutes of inactivity.
①Hold / Freeze reading icon
②Auto power off icon
③Temperature readings
④Sound level readings
⑤Fast / Slow icon
⑥Hi / Lo icon
⑦
Low battery indication icon
⑧
⑨
MAX/MIN reading icon
6. LCD display explainations
1
2
3
4
5 6
8
9
7
10
Hold MAX MIN
SLOW FAST HiLo dBA
˚C ˚F
When the battery warning icon ‘ ’
display on the LCD, push the battery cover out
and replace 3 pcs. fresh AAA battery
as the correct polarity. To avoid chemical leakage
from the battery, remove the battery if you are
intended not to use the meter for a while
7. How to replace the battery
Temperature unit icon
Frequency weighting icon
Fast
Slow
8. How to use
HOLD
HOLD
HOLD
Fast
Slow
9. Notes
This meter has already been calibrated before delivery. Do not revise the calibration parameters
without professional personnel and device.
All products are well calibrated before delivery.Recommended recalibration at 1 year intervals.
Repairs or servicing not covered in this manual should only be performed by qualified personnel.
Wipe the unit with a dry soft cloth periodically. Do not use abrasives or solvents on this instrument.
Remove the battery when the meter is to be stored for long periods of time to avoid battery leakage.
When the battery is low, LCD display “ ”, a new battery is needed to replace.
Do not store or operate the meter in high temperature or humidity.
Wind blowing across the microphone increases the noise measurement, Use the supplied
windscreen to cover the microphone when appliance.
Keep microphone dry and avoid severe vibration.
3
⑩
A)
B)
C)
D)
E)
F)
G)
H)
2 in 1
4
Other products from MEET
- 0 to 200,000 Lux
- Auto range
- Measures Lux or
Foot-Candles (FC)
- High accuracy and fast
response sampling time
- With Temperature
measurement
- Convert temp. in
°C / °F
- Color LCD display
with backlight
- Over range indication
- MAX / MIN record
reading
- Enable / Disable
auto power off (APO)
- Low battery indication
- Hold / Freeze reading
Anemometer
MS-912
MS-915
Temperature and Humidity meter
MS-913
2 in 1
2 in 1
- Measure Humidity, Air /
Dew Point /
Wet Bulb Temperature
- High accuracy humidity
& temperature sensor
- MAX. / MIN. reading
display
- Color LCD display
with backlight
- Convert temperature
in °C / °F
- Over range indication
- Enable / Disable
auto power off (APO)
- Low battery indication
- Hold / Freeze reading
- High accuracy, fast response
- Air velocity and temperature measurement
- Selectable measurement units: m/s, ft/min,
MPH, km/hr or knots
- MAX. / MIN. reading display
- Color LCD display with backlight
- Convert temperature in °C / °F
- Over range indication
- Enable / Disable auto power off (APO)
- Low battery indication
- Hold / Freeze reading
- Features and specifications are subject to change without prior notice.
Copyright © 2019 Meet International Ltd. All rights reserved www.meet.com.hk
Lux / Light Meter
Other MEET Technology Measuring Instrument manuals