MegaLite Pro Color Cannon User manual

USER MANUAL
Table of Contents
Safety Information……………………………………………………………………………………………. 3
Specifications……………………………………………………………………………………………………..4
Main Power Connection…………………………………………………………………………………..5
DMX-512 Connection…………………………………………………………………...……………......5
DMX Profile......................................................................................................................... 6
Main Control Menu.......................................................................................................... 7
Rigging the Fixture…………………………………………………………………………………………….9
Cleaning & Maintenance................................................................................................9
Parts List.............................................................................................................................. 9


Check that the unit has not been damaged during transport
Protection Against Fire
1. Maintain a minimum of 1 foot distance from any type of flame.
3. Replace fuse only with the specified type and rating.
4. Do Not install the unit to close to a heat source.
5. Make sure cable are properly secured away from unit movement.
6. Maximum surface operating temperature 80º.
Protection Against Fire
1. Disconnect power before servicing.
2. For connection to main power supply proceed to page 5.
3. This unit must be earthed. (electronically grounded)
4. Do not expose unit to rain or moisture.
Protection Against Mechanical Hazards
1. Use safety chain when hanging unit.
2. Use quality clamps or bolts when positioning unit
3. Do not open unit while it is on, risk of electrical shock.
3

Technical Information
4
Catalog Logic
3000- Pro Color Cannon Black Housing
3001–Pro Color Cannon White Housing
Mechanical Specifications
Fixture Packaged for Shipping
Size: 9.5”x 8.75”x 11.25”
Weight: 6 lb
Size: 14”x 10”x 11.5”
Weight: 7.5 lbs
DMX Connectors: 3-pin & 5 Pin XLR connectors
Power Connection: Neutrik Power Con in/Out
Thermal: Maximum ambient temperature 40° C
Maximum surface temperature 60° C
Fastening System: Double Mounting Yoke & Security Eye bolt
Accessories: 1 / Edison power head to Blue Power Con cable (included)
1 / White Power Con head (included)
Electrical Specifications
LED Quantity: 36
LED Type (Options) : Tri Colored RGB
Tri Colored WWA
Red, Green, Blue
White, White, Amber
LED Watts: 3
LED Lifetime: 60 to 100 thousand hours
LED Angle (Options): 15° ( ± 5º)
30° ( ± 5º)
60° ( ± 5º)
Protocol: DMX 512
DMX Channels: Mode A 3 Channels R,G,B
Mode P 4 Channels Dimmer/Strobe, R,G,B
Mode F 6 Channels R ,G ,B, Strobe, Macro , Dimmer
Control options: Audio-trigger
Control & Programming
TRGB–Tri Colored RGB
TWWA–Tri Colored WWA
RGB–3 Watt Red, Green, Blue
WWA–3 Watt White, White, Amber
Power Consumption: 110V-220V50/60 Hz
Ballast: Electronic
Watts: 71
Amps: .91
15- 15°Lens Kit
30- 30° Lens Kit
60- 60° Lens Kit
Housing LED Module Lens Module Options
BD-Barn Door
GH-Gel Holder
3000 RGB 30 -xx
7.75””
9.5””8.75””
3.5””
7.1/16

5
Main Power Connection
Caution!
1. Do not connect fixture to a dimmer system.
2. This unit has Auto switching power supply. It will respond to 110V or 220V automatically
3. This unit must be earthed. (electronically grounded)
4. Replace fuse only with the specified type and rating.
The occupation of the connection-cable is as follows:
12
3
1
3
2
DMX-512 Connection
This fixture is equipped with an electronic power supply that will let the unit operate from 90V to 240V from 50Hz to 60Hz
The fixture is equipped with 3 pin and 5 pin XLR Sockets for DMX input and output. The sockets are wired in parallel. Only use a
shielded twisted pair cable designed for RS-485 and 3 pin XLR plugs and connectors in order to connect the controller with the
fixture or the fixture with another.
DMX—input DMX—output
1. Shield
2. Signal (-)
3. Signal (+)
Caution!
At the last fixture the DMX signal needs to be terminated with a terminator. Solder a 120
Ohm resistor between the (-) and the (+) signal into a 3 pin XLR plug and plug it in to the
last fixture on the signal run. Pre-manufactured terminator plugs are available for
purchase from your Mega-Lite dealer (HOS-DMXT).
Cable (USA) Cable (EU) Pin 110V
Black Brown
White
Green
Light Blue
Yellow/Green
Live
Neutral
Ground
L
N
L
L
220V
L
L
110V
Connection
220V
Connection
N
L
1
3
2
4
5 1
2
3
4
5

Pro Color Cannon Mode A
DMX Chanel Function Description Value
1 LED Color Red LED intensity 0-255
2 LED Color Green LED Intensity 0-255
3 LED Color Blue LED Intensity 0-255
Pro Color Cannon Mode P
DMX Chanel Function Description Value
Dimmer 0-152
1 Dimmer Strobe (slow to fast) 153-242
Dimmer Full On 243-255
2 LED Color Red LED intensity 0-255
3 LED Color Green LED Intensity 0-255
4 LED Color Blue LED Intensity 0-255
Pro Color Cannon Mode F
DMX Chanel Function Description Value
1 LED Color Red LED intensity 0-255
2 LED Color Green LED Intensity 0-255
3 LED Color Blue LED Intensity 0-255
4 Strobe Strobe (slow to fast) 0-255
No Function 0-1
Color fade (slow to fast) 2-19
Color Snap (slow to fast) 20-39
Random (slow to fast) 40-59
Yellow 60-79
Purple 80-99
5 Macro Aqua 100-119
Orange 120-139
Red Pulse 140-159
green Pulse 160-179
Blue Pulse 180-199
Yellow Pulse 200-219
Aqua Pulse 220-229
White Pulse 230-249
White LED Full 250-255
6 Dimmer Dimmer Off to Full 0-255
6

7
Main Control Menu
The control board on the fixture base is your interface to access and control
all the functions on the unit. Its digital display gives you a code view of the
options and functions. The following will explain each function and its options.
Menu
DMX Address
Red Dimmer
Press Enter to select the mode of operation.
Use the up/down keys to select the required DMX start channel.
This function allows you to dim the red LED’s on the whole strip. Press Enter use the up/down keys to select desired dimmer
settings. Press Enter to confirm the settings.
Up Down Enter
CONTROL BOARD
DMX Address Red Dimmer Green Dimmer Blue Dimmer Flash Fade Scroll Flash Scroll Chase Effect Chase Speed Sound Chase Sound Flash Sound Sensor
1-512 0-15 0-15 0-15 0-15 0-15 0-15 0-15 0-15 Loop Loop 0-15
Mode A(3 Channels) R,G,B
Mode P (4 Channels) Dimmer/ Strobe, R,G,B
Mode F (6 Channels) R,G,B, Strobe, Macro, Dimmer
Green Dimmer
This function allows you to dim the green LED’s on the whole strip. Press Enter use the up/down keys to select desired dimmer
settings. Press Enter to confirm the settings.
Blue Dimmer
This function allows you to dim the blue LED’s on the whole strip. Press Enter use the up/down keys to select desired dimmer
settings. Press Enter to confirm the settings.
Flash
This function allows you to strobe the LED’s on the whole strip in White color. Press Enter use the up/down keys to select de-
sired flash settings. Press Enter to confirm the settings.

8
Fade Scroll
This function allows you to fade the LED’s on the whole strip from one color to another. Press Enter use the up/down keys to
select desired fade speed settings. Press Enter to confirm the settings.
Flash Scroll
This function allows you to change the LED’s on the whole strip from one color to another. Press Enter use the up/down keys to
select desired color change speed settings. Press Enter to confirm the settings.
Chase Effect
This function allows you to select different chase patterns on the whole strip. Press Enter use the up/down keys to select de-
sired chase settings. Press Enter to confirm the settings.
Chase Speed
This function allows you to select the speed of the chase that was selected on the Chase function . Press Enter use the up/down
keys to select desired chase speed settings. Press Enter to confirm the settings.
Sound Chase
This function allows you to select the chase pattern that will be triggered via audio. Press Enter use the up/down keys to select
desired Chase settings. Press Enter to confirm the settings.
Sound Flash
This function allows you to select the flash pattern that will triggered via audio. Press Enter use the up/down keys to select de-
sired dimmer settings. Press Enter to confirm the settings.
Sound Sensor
This function allows you to select the sensitivity of the audio sensor. Press Enter use the up/down keys to select desired dimmer
settings. Press Enter to confirm the settings.

Cleaning and maintenance
Installation Maintenance: The operator has to make sure that the unit is operating safely and has the installations and electron-
ics checked by an expert every 2 years.
The following points have to be considered during the inspection:
1) All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
2) There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing).
3) The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further
instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems
have to be removed.
Note: There is no serviceable parts inside the device except for the LED’s. Maintenance and service operations are to be carried
out by authorized dealers.
Replacing the fuse: Only replace the fuse with the same type and rating.
Replacing the power cable: If the power cable of this device becomes damaged, it has to be replaced by authorized dealers or
trained professional only.
Should you have further questions , please contact your dealer.
9
Parts List
3000-pcb Main PCB card
3000-ps Power Supply
4000-dis Display
4000-fh Fuse Holder
9056 Quad Cannon Road Case
Rigging the fixture
Caution!
1. The installations must be carried out by an authorized dealer or trained professional.
2. Unit may cause severe injures if you have doubts concerning the safety do not install.
3. Unit is to be 24inches away from flammable materials (decoration material)
4. Use high quality installation equipment to hang unit.
When rigging a unit it is very important that you follow common safety procedures. Rigging requires extensive experience includ-
ing but not limited to calculating working loads, material being used and periodic safety inspections. If you lack these qualifica-
tions, do not attempt the installation yourself, instead use a professional structural rigger.
When rigging the unit always be secured with a secondary safety attachment. The installation location of the projector has got to
be built in the way that it can hold 10 times the weight for 1 hour with out any harming. Installation should be checked at least
one time a year by a skilled person.
4001502
CONFORMS TO UL STD 1573
ETL LISTED
STAGE AND STUDIO
LUMINAIRES

Mega-Lite
5718 Kenwick St
San Antonio, TX 78238
Ph 210-684-2600 Fax 210-855-6279
www.mega-lite.com / info@mega-lite.com
Warranty Information
Limited Warranty
Unless otherwise stated, your product is covered by a one year parts and labor limited warranty. Dichroic filters and glass gobos are not guaranteed
against breakage or scratches to coating. It is the owner’s responsibility to furnish receipts or invoices for verification of purchase, date, and dealer
or distributor. If purchase date cannot be provided, date of manufacture will be used to determine warranty period.
Returning an Item Under Warranty for Repair
It is necessary to obtain a Return Material Authorization (RMA) number from your dealer or point of purchase BEFORE any units are returned for
repair. The manufacturer will make the final determination as to whether or not the unit is covered by warranty. Lamps are covered by the lamp
manufacturer’s warranty.
Any Product unit or parts returned to MEGA Systems Inc. must be packaged in a suitable manner to ensure the protection of such Product unit or
parts, and such package shall be clearly and prominently marked to indicate that the package contains returned Product units or parts and with an
RMA number. Accompany all returned Product units or parts with a written explanation of the alleged problem or malfunction. Ship returned Prod-
uct units or parts to: 5711 Kenwick St. San Antonio TX 78254 USA.
Note: Freight Damage Claims are invalid for fixtures shipped in non-factory boxes and packing materials.
Freight
All shipping will be paid by the purchaser. Items under warranty shall have return shipping paid by the manufacturer only in the Continental United
States. Under no circumstances will freight collect shipments be accepted. Prepaid shipping does not include rush expediting such as air freight. Air
freight can be sent customer collect in the Continental United States.
REPAIR OR REPLACEMENT AS PROVIDED FOR UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER.
MEGA SYSTEMS INC. MAKES NO WARRANTIES, EXPRESS OR IMPLIED, WITH RESPECT TO ANY PRODUCT, AND MEGA SYS-
TEMS SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. MEGA
SYSTEMS SHALL NOT BE LIABLE FOR ANY INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGE, INCLUDING LOST PROF-
ITS, SUSTAINED OR INCURRED IN CONNECTION WITH ANY PRODUCT OR CAUSED BY PRODUCT DEFECTS OR THE PARTIAL
OR TOTAL FAILURE OF ANY PRODUCT REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, TORT (INCLUDING
NEGLIGENCE), STRICT LIABILITY OR OTHERWISE, AND WHETHER OR NOT SUCH DAMAGE WAS FORESEEN OR UNFORESEEN.
Warranty is void if the product is misused, damaged, modified in any way, or for unauthorized repairs or parts. This warranty gives you specific
legal rights, and you may also have other rights which vary from state to state.
Table of contents
Other MegaLite Floodlight manuals

MegaLite
MegaLite 4070-N-E Color Punch User manual

MegaLite
MegaLite Obra Flood N180 User manual

MegaLite
MegaLite Drama W LED User manual

MegaLite
MegaLite Drama FS-LED 700 User manual

MegaLite
MegaLite UniColor User manual

MegaLite
MegaLite Baby Color Q70 User manual

MegaLite
MegaLite Indi PAR RW300 User manual

MegaLite
MegaLite N-E Color Wash User manual

MegaLite
MegaLite Outshine T100 User manual

MegaLite
MegaLite VAZT LED P100 User manual