Megger CP-600DC-ID User manual

Other Megger Measuring Instrument manuals

Megger MJOLNER 200 User manual

Megger

Megger MJOLNER 200 User manual

Megger TDR2000/3 User manual

Megger

Megger TDR2000/3 User manual

Megger DPM1000 User manual

Megger

Megger DPM1000 User manual

Megger MPQ1000 User manual

Megger

Megger MPQ1000 User manual

Megger IDAX Series User manual

Megger

Megger IDAX Series User manual

Megger DET14C User manual

Megger

Megger DET14C User manual

Megger DCM1500S User manual

Megger

Megger DCM1500S User manual

Megger DLRO100EB User manual

Megger

Megger DLRO100EB User manual

Megger DLRO10HD User manual

Megger

Megger DLRO10HD User manual

Megger MOM690 User manual

Megger

Megger MOM690 User manual

Megger Baker DX Series User manual

Megger

Megger Baker DX Series User manual

Megger Ducter DLRO2X User manual

Megger

Megger Ducter DLRO2X User manual

Megger MFT1845 Installation and operating instructions

Megger

Megger MFT1845 Installation and operating instructions

Megger DCM320 User manual

Megger

Megger DCM320 User manual

Megger DCM310 User manual

Megger

Megger DCM310 User manual

Megger DLRO-10 User manual

Megger

Megger DLRO-10 User manual

Megger CFL510F User manual

Megger

Megger CFL510F User manual

Megger HVB 10 User manual

Megger

Megger HVB 10 User manual

Megger TDR900 User manual

Megger

Megger TDR900 User manual

Megger KF-LAB Mk II User manual

Megger

Megger KF-LAB Mk II User manual

Megger AVO210 User manual

Megger

Megger AVO210 User manual

Megger VCLAMP User manual

Megger

Megger VCLAMP User manual

Megger HV DAC-200 User manual

Megger

Megger HV DAC-200 User manual

Megger PDS 62-SIN User manual

Megger

Megger PDS 62-SIN User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CP-600DC-ID Guide
84744 Rev 2 Sept 2015
GENERAL
The CP-600DC-ID is a split core CT meant for
operation with the Megger Power Quality Line
of Instruments. This current clamp will measure
both AC and DC current. This CT is NOT
powered by the unit. This CT requires a 9V
battery to operate.
NOTE: If using this CT with a PA-9 series
power quality analyzer the PA-9
current full scale value MUST be
set to 1000.
SAFETY and SYMBOLS
WEEE
The crossed out wheeled bin placed
on Megger products is a reminder
not to dispose of the product at the
end of its life with general waste.
Megger is registered in the UK as a
Producer of Electrical and
Electronic Equipment. The
Registration No is WEE/DJ2235XR.
Equipment complies with current
EU directives.
Application around or removal from
hazardous live conductors is
permitted.
Equipment protected throughout by
double insulation.
G
CAUTION is defined as a condition
or practice which could result in
damage to or destruction of the
equipment or apparatus under test.
F
WARNING is defined as a condition
or practice which could result in
personal injury or loss of life.
Safety warnings are precautions that must be
read and understood before the instrument is
used. They must be observed during use.
Do not leave the instrument connected to the
system under test when not in use.
Always use extreme caution when connecting
the instrument around bare conductors, under
fault conditions, high voltage or currents may
be present and may pose a shock hazard.
Personal protective equipment (PPE) must be
used during the installation and removal of this
instrument from hazardous live connectors.
Do not touch circuit connections or any metal
that is exposed due to damaged insulation.
Do not use the instrument or connect it to any
external system if it shows any visible signs of
damage, malfunction or if it has been stored in
unfavorable conditions.
Always inspect the instrument prior to use.
Replace any defective parts or return the
instrument to an authorized center for repair.
Do not use the instrument or connect it to any
external system if the enclosure is open or any
parts of the enclosure are missing.
Only use specified batteries as described by
this document, if applicable.
The instrument shall not be used if any parts
are damaged.
Always connect the probe to the instrument
prior to connecting to the source.
This instrument is not intrinsically safe and
must not be used in hazardous atmospheres.
If this equipment is used in the manner not
specified by the manufacturer, the protection
provided by the equipment may be impaired.
SPECIFICATIONS
Working / Common Mode Voltage: 600Vrms
Current Range 1 to 600A
Scale 1mV / Amp
Load Impedance >100KΩ/ 100pF
Bandwidth: DC to10KHz @ -3dB
Accuracy:
400A Range
1 to 100A = 1.5% of reading
+/- 1A
100 to 400A = 2% reading
Accuracy
600Adc Range
400 to 600A (DC ONLY) =
2.5% of reading
Phase Shift 1 to 200A ≤2.5°
200 to 400A ≤2.0°
Overload 2000Adc & 1000Aac
Continuous up to 1KHz
Power Source 9V Alkaline Batteries NEDA
1604A, IEC 6LR61 (120-HR
LIFE)
Jaw Opening 1.2 inches (31mm)
Dimensions 8.8x3.82x1.73”
(224x97x44mm)
Weight 15oz (440g)
Operating
Temperature
-10 – 55C
Storage
Temperature
-40 – 80C
Humidity 10-35C 90% +/- 5% NC
40-55C 70% +/- 5% NC
IEC61010-2-032: 2012
EN50081-1 Class B
EN50082-2 Electrostatic Discharge; IEC61000-4-2
Radiated Field IEC61000-4-3
Fast Transient IEC61000-4-4
Magnetic Field 50/60Hz IEC61000-4-8
600V CAT III, Pollution Category 2
*Reference conditions: 23°C ±3°K, 20 to 75% RH, 48 to
65 Hz, external magnetic field < 40 A/m, no DC
component, no external current carrying conductor, test
sample centered. Load impedance 1MΩ.
CP-600DC-ID Guide
84744 Rev 2 Sept 2015
OPERATING CONTROLS
Power Switch: The power OFF / 600 switch
turns the CT on and off.
OPERATING INSTRUCTIONS
Installation
GPersonal protective equipment
(PPE) must be used during the
installation and removal of this
instrument.
1. Connect the CT to Megger PQ device.
2. Set the power selector switch to the 600
position. Verify the ON lamp is illuminated
green. If not then change the 9V alkaline
battery in the CT.
The battery is good for up to 120 hours.
NOTE If using this CT with a PA-9 series
power quality analyzer the PA-9
current full scale value MUST be
set to 1000.
3. View the current on the PQ Analyzer and
use the CT’s zero adjustment knob to null
out any offset.
4. Use the lever to open the jaw and place
the CT around the source to be measured.
Removal
1. Use the lever to open the jaw and remove
the CT from the source being measured.
2. Set the OFF / 600 switch to the OFF
position. Failure to do so will drain the 9V
battery in the current clamp.
3. Disconnect the CT from PQ Analyzer
MAINTENANCE
GHave maintenance performed
only by qualified service
personnel.
Cleaning and Decontamination
Do not clean with anything more than a clean
dry cloth.
Battery Replacement
Do not change batteries while the current
clamp is installed around a conductor.
The crossed out wheeled bin placed on the
batteries is a reminder not to dispose of them
with general waste at the end of their life. This
product contains alkaline batteries located in
the NEMA housing.
They can be safely removed by removing the
screw on the back of the CT. Then replace the
9V alkaline battery and re-install the back
cover of the CT.
Spent alkaline batteries are classified as
Portable Batteries and should be disposed of in
the UK in accordance with Local Authority
requirements.
For disposal in the UK contact Megger Ltd.
For disposal of batteries in other parts of the
EU contact your local distributor.
Megger is registered in the UK as a producer
of batteries. The Registration number is
BPRN01235.
M
2621 Van Buren Ave
Norristown, PA 19403-2329
610-676-8500
www.megger.com