Metra Electronics ELDLISS User manual

Door Access Terminal User Manual

Page 2
Door Access Terminal User Manual
Table of contents
Door Access Terminal User Manual ........................................................................................................ 3
Product description............................................................................................................................. 3
Basic Parts ........................................................................................................................................... 4
User Interface...................................................................................................................................... 4
Operating indicator............................................................................................................................. 5
User card presentation ....................................................................................................................... 5
Passage Allowed ............................................................................................................................. 5
Passage denied ............................................................................................................................... 6
Signal not activated ........................................................................................................................ 6
Master card presentation ................................................................................................................... 6
Latch/Unlatch function ....................................................................................................................... 7
User card with permanent option presented................................................................................. 7
Master card presented ................................................................................................................... 8
Alarm signalization.............................................................................................................................. 9

Page 3
Door Access Terminal User Manual
Door Access Terminal User Manual
Manufacturer:
Metra inženiring d.o.o.
IOC Trzin
Špruha 19
SI-1236 Trzin, Slovenia
phone:
fax:
web:
+386 1 56 10 740
+386 1 56 10 744
www.metra.si
System:
Metra Access Control System
Product Group:
Door Access Terminal
Types:
ELDLISS, ELDLISU, ELDLISS_G01, ELDLISU_G01 (ISO14443A/B, ISO 15693)
ELDLLFS, ELDLLFU (LF Multitag)
ELDLLGS, ELDLLGU, ELDLLGS_G01, ELDLLGU_G01 (Legic)
ELDLMFS, ELDLMFU (Mifare, ISO14443A/B)
ELDLSDS, ELDLSDU, ELDLSDS_G01, ELDLSDU_G01 (SkiData)
Year of Construction:
2004 - 2007
Declaration of Conformity:
Metra Access Control products have been developed, designed and
manufactured in accordance with the EU directive for Electromagnetic
Compatibility (2004/108/EC).
Door Access Terminal User Manual [rev.4-230611]
2011 Metra inženiring d.o.o.
All Rights reserved.
No part of this manual may be reproduced in any form or by any means without prior written permission of Metra inženiring d.o.o.
The contents of this manual are subject to change without notice.
All efforts have been made to ensure the accuracy of the contents of this manual, however, should any errors be detected, Metra inženiring would greatly appreciate being informed of
them. Metra inženiring d.o.o. can assume no responsibility for any errors in this manual.
Product description
Door Access Terminal (DAT) is designed to form a
one-way check point for various types of tickets. It
gives a single relay signal for access mechanisms such
as electric door strike, etc. Normally it is mounted
near door where passage control is needed. It comes
in different versions, according to the type of ticket
and mounting (surface or built-in). Higher security
can be achieved by connecting an Extension Relay
Board.
Door Access Terminal operates on line with Metra
software. It must be connected to Metra NET
Network. When RFID ticket is presented access rights
are checked in the Metra database. If valid the unit
triggers its relay.
Passage on Door Access Terminal for particular ticket
can also be externally controlled by 3rd party SW via
TCP/IP software interface.
Operating parameters are defined in Metra software.
Event data from device is used for further analyses
with this software.

Page 4
Door Access Terminal User Manual
Basic Parts
#
description
#
description
1
OK signal
3
OPERATE (Power) signal
2
NO signal
4
Antenna field
Standard models are supplied with front mask in gray colour. For additional colours contact Metra
sales.
User Interface
Door Access Terminal user interface uses optical signals ( , and ) and an acoustic beeper
signal to inform the user about operation progress. Signals are explained in the tables below.
OK signal (green)
state
Description
on
passage enabled (lock unlocked) short beep acoustic signal
NO signal (red)
state
Description
flashing
RFID media recognized but passage denied interrupted acoustic signal
OPERATE signal (blue)
state
Description
flashing
device operates normally

Page 5
Door Access Terminal User Manual
Operating indicator
When the unit is running a blue OPERATE signal light is flashing.
User card presentation
Approach the card to the antenna field. Reading distance
is 3 –5 centimetres from the device surface. Hold the card
in field for a few moments for Door Access Terminal to
read and process the card.
Short Acoustic signal is activated when the cards is
recognized.
Passage Allowed
When card is accepted, “OK” optical signal lights up.
The door is unlocked.
Remove the card form the antenna filed.

Page 6
Door Access Terminal User Manual
Passage denied
If the card is rejected (passage not allowed) “NO” optical
signal is flashing and interrupted acoustic signal is
activated for 2 seconds.
Door remains locked.
Remove the card form the antenna filed.
Signal not activated
If there is no optical signal (door remains locked) the
device is not functioning properly. Call maintenance
personnel.
Master card presentation
STEP 1: Approach the MASTER card to the antenna field.
Reading distance is 3 –5 centimetres from the device
surface. Hold the card in field for a few moments for Door
Access Terminal to read and process the card.

Page 7
Door Access Terminal User Manual
STEP 2: When the MASTER card is recognized, “OK” optical
signal lights up and short acoustic signal is activated.
The door is unlocked.
Remove the card form the antenna filed.
Latch/Unlatch function
Latch/unlatch functionality allows user to permanently open the door lock for prolonged period of
time. This function is especially useful for conference rooms, maintenance purposes and in
emergency cases.
User card with permanent option presented
NOTE
Latch/Unlatch function must be enabled in operating parameters and user card must be
programmed for latch/unlatch functionality!
STEP 1: Approach the card to the antenna field. Reading
distance is 3 –5 centimetres from the device surface. Hold
the card in field for a few moments for Door Access
Terminal to read and process the card.
Short Acoustic signal is activated when the cards is
recognized.
STEP 2: When card is accepted, “OK” optical signal lights
up.
The door remains unlocked (latched) and “OK” optical
signal remains on.
Remove the card form the antenna filed.
NOTE
Repeat the procedure to deactivate (unlatch) the door lock. “OK” optical signal is also deactivated.

Page 8
Door Access Terminal User Manual
Master card presented
NOTE
Latch/Unlatch function with Master card is always possible and it cannot be disabled!
STEP 1: Approach the MASTER card to the antenna field.
Reading distance is 3 –5 centimetres from the device
surface. Hold the card in field for a few moments for Door
Access Terminal to read and process the card.
STEP 2: When the MASTER card is recognized, “OK” optical
signal lights up and short acoustic signal is activated.
The door is unlocked.
STEP 3: Do not remove the MASTER card from the
antenna field until beep-beep acoustic signal is activated
(after 4 seconds).
The door remains unlocked (latched) and “OK” optical
signal remains on.
Remove the MASTER card form the antenna filed.
NOTE
Repeat the procedure to deactivate (unlatch) the door lock. “OK” optical signal is also deactivated.

Page 9
Door Access Terminal User Manual
Alarm signalization
When Alarm is triggered the interrupted acoustic signal
and “NO” optical signal are activated.
Alarm can be triggered (if selected in operating
parameters) by various actions. To activate door brake-in
or door opened too long time alarm the door must be
equipped with tamper sensor.
If Door Access Terminal housing is equipped with optional
mini tamper sensor alarm is triggered, when trying to
disassemble it.
Consult Door Access Terminal Technical Manual for
details.
This manual suits for next models
15
Table of contents
Other Metra Electronics IP Access Controllers manuals