Working principle
This reader generates a continuous RF signal in the band from
902 - 928 MHz.
•When a passive tag (card, sticker or car plate type), carried by a user or fixed
on a vehicle enters into the RF field, generated by the reader, a small
perturbation occurs: the tag then replies with an encrypted signal, that
includes its s/n and more information. These are then detected by the reader
which transmits the signal to the decrypting I/F device, that makes them
available in Wiegand format or activates a relay.
•The Wiegand signal can be read by an Access Control System that that gives
the final authorization to the user final authorization to the user.
•The reader comes with the corresponding I/F device which has a built-in RF
receiver, operating at 433.92 MHz, with a memory for 100 Erone Keeloq type
remote controls.
•The remote control can be used as an alternative means of identification
from longer range, with the high security level provided by our Keeloq
hopping code.
2UHF Range
Fig. 2
3Technical specications : Reader
12 in.
12 in.
3.15 in.
General descriptionGeneral description
The DOLCWIUHF-ER-902 is a high-performance UHF RFID integrated reader. It supports fast tag read/write
operation with high identification rate. It can be widely applied in many RFID application systems such as logistics,
access control, anti-counterfeit and industrial production process control systems.
Part-name Description
READER UHF 10M 902 MHz BLACK
READER UHF 10M 902 MHz WHITE
ADHESIVE TAG UHF TAMPER-PROOF
ADHESIVE TAG UHF
CARD HOLDER BRACKET
CARD TAG UHF
CAR PLATE TAG UHF
(*) Eective distance depends on antenna, tag and environment(*) Eective distance depends on antenna, tag and environment
Fig. 1
DOLCWIUHF-ER-902-B : front view DOLCWIUHF-ER-902-B : rear view DOLCWIUHF-ER902-W : rear view
Operating frequency range....................902 - 928 MHz
Transmission type ................................FHSS
Detection range in open space .............<20 m (*)
Rated Power supply .............................12 Vdc
Stand-by max current ...........................200 mA @12 Vdc
Max current consumption .....................1 A @12 Vdc
Operating temperratturre.......................68° F to 131° F
Storage temperature............................ 104° F to 185° F
Operating humidity ...............................<95%RH (+77o F)
Weight....................................................4lb. 13oz.
Protocol tag supported .........................ISO 18000-6C/6B
RF output power...................................up to 33 dBm (adjustable)
Polarization...........................................Circular
Output ..................................................RS-485
Dimensiions..........................................12 x 12 x 3.15 in.
IP Class ...............................................IP65
DOLCWIUHF-ER902-B
DOLCWIUHF-ER902-W
CARMANSTIUHF-ER-TP
CARMANSTIUHF-ER
CARMANUHFHOL-ER
CARMANISOUHF-ER
CARMANLP-ER

2
5Mounting the reader
RF Reader
Mounting pole
Mounting bracket
( included )
7 ft
4Technical specications : I/F w/built-in radio receiver
Fig. 3
RXU4GO
CDVI
123
81,5 41,5
Operating frequencyOperating frequency ................................... ................................... 433,92 MHz433,92 MHz
DemodulationDemodulation ............................................. .............................................OOKOOK
Sensitivity ( for good signal ) Sensitivity ( for good signal ) ..................... .....................-115 dBm-115 dBm
Power supply:Power supply: ............................................. ............................................. 12/24 Vac/dc12/24 Vac/dc
Current consumption ( @12 Vdc )Current consumption ( @12 Vdc ) .............. .............. from 25 to 50 mA (max)from 25 to 50 mA (max)
EncryptionEncryption......................................................................................................Rolling code w/encoding KeeloqRolling code w/encoding Keeloq
Input Input ......................................................................................................................RS-485RS-485
N° UHF readers supported N° UHF readers supported ........................ ........................ 22
OutputsOutputs ....................................................... ....................................................... Relay, WiegandRelay, Wiegand
Wiegand protocols supportedWiegand protocols supported ..................... .....................26 - 30 - 44 bit26 - 30 - 44 bit
Memory capacityMemory capacity ........................................ ........................................7580 tags7580 tags
........................................................................................................................................100 remote controls100 remote controls
RelaysRelays..................................................................................................................2 x 24 VA - max 48Vdc2 x 24 VA - max 48Vdc
Relay operating modeRelay operating mode ................................ ................................pulse , step, delayedpulse , step, delayed
DelayDelay .......................................................... ..........................................................from 1 sec. to 23 h : 59 minfrom 1 sec. to 23 h : 59 min
Retransmission period over wiegand busRetransmission period over wiegand bus......from 100 mS to 2 Sec.from 100 mS to 2 Sec.
Relay pulse Relay pulse ................................................ ................................................300 mS300 mS
Operating temperatureOperating temperature:: .............................. -50° to 140° F
Enclosure IP protectionEnclosure IP protection:: ............................. .............................IP55IP55
DimensionsDimensions:: ................................................................................................4.7 x 3.2 x 1.7 in.
WWeighteight ...............................................................................................................2.3 oz..
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
EN
Fig. 4

7Connections
www.erone.com - www.cdvigroup.com 3
Power supply
( included )
Wiegand
2
2
110 - 230 Vac
3
3
RF Reader
RXU
2
6Mounting the I/F receiver
Option A ) Drill an 11mm hole in the bottom back of
the box and pass the cable through
Option B ) Drill 11mm
hole(s) and use PG7
cable glands (not
provided)
Drill the mounting surface
with a 6mm drill bit and
insert the 2 plastic
anchors
Secure the mounting plate
with the screws provided
Fig. 5
AHU49
AHU49
Power
Data
Relays 4
EN
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
Trigger
Fig. 6

8 Wiring Diagram
Button activated
a, b, c or d
TX Serial
number
Relay activated The factory value for the timing is 1
sec. Use P1 to scroll the digits and P2
to conrm
Relay 1 : Pulse Relay 1 : Step
Relay 2 : Timed
Delay setting
F F F N N N N N
R 1 a b c d R 2
Example 1: TX reception
R 1
P U L S E
R 1
S T E P
R 2
0 0 : 0 1 : 0 5
h h m m s s
0 0 : 0 0 : 0 1
R 2
D I S A B L E D
Relay 2 : Disabled
Example 2 : Status of the relays
Ref Description Wire type Optional extension size Maximum length
(1) Cable from reader
( 0,7m )
2 conductors ( RS485 bus) 24AWG ( 0,51 mm2 )4000 ft
2 conductors ( Power supply) 18AWG ( 1,02 mm2 )L1 = 100 ft MAX
(2) Wiegand BUS 3 conductors Belden 9553 22AWG ( 0,64 mm2 ) to 18AWG ( 1,02 mm2 )490 ft
(3) Power supply 2 conductors 18AWG ( 1,02 mm2 )L1 = 100 ft MAX
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
EN
4
FFF = FACILITY CODE
NNN = SERIAL NUMBER
Trigger signal Reader operating mode
Floating / connected to GND Reading
Connected to Vdc Disabled (*)
(*) : use an external device with a dry contact to enable/disable the (*) : use an external device with a dry contact to enable/disable the
detection of the readerdetection of the reader
P4 : back to
upper level
P3 : enter the menu
( 4 sec.)
or
conrm the choice
P1, P2 :
navigate
the menu
Backlit
LCD Display
Connector for
backup memory
Power supply ( included ).
NOTE: for indoor installations only.
White
Green
Black
Red
Buzzer
UHF
RECEIVER
J2 ON = 9VJ2 ON = 9V
J2 OFF = 5VJ2 OFF = 5V
GNDGND
Wiegand Out
D0D0
D1D1
R1R1
R2R2
Pull-UPPull-UP WWiegandiegand
RED +12dcRED +12dc
BLACK GNDBLACK GND
RG58RG58
Fig. 7
P1 P2 P3 P4
AA
BB
110 - 230 Vac
3
RF Reader 1
SEA433SEA433
L1L1
(1)(1)
(2)(2)
(3)(3)
RF Reader 2
AA
BB
(1)(1)
110 - 230 Vac REDRED
++12dc12dc
BLACKBLACK
GNDGND
White
Green
Black
Red
TTriggerrigger
TTriggerrigger

11 Overhead Installation
10 Side installation
9Compatible UHF Tags
Ticket box Pole
Reader
Barrier
Ticket box
Overhead
installation
Reader
Barrier
Control
room
Barrier
EN
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
www.erone.com - www.cdvigroup.com 5
Part No: CARMANSTIUHF-ST
V2 UHF Sticker
Part No: CARMANISOUHF
Dual Protocol UHF
& Mango® Card
Part No: MANUHFHOL
UHF Card Holder
UHF Card
Part No: CARMANISODUOUHF
UHF Sticker
Part No: CARMANSTIUHF
UHF Hang Tag
Part No: CARMANHT
UHF License Plate Tag
Part No: CARMANLP

12 Getting started
13 Programming / Navigation menu
Menu
Output
Menu
Add Tag
Menu
Del Tag
Menu
Add Tx
Menu
Del Tx
Menu
Settings
Menu
Confi
Menu
Backup
RXU4Go
CDVI
Menu
Info
P2: scroll down
Password
Menu
Exit
Select the operating output mode of the RF receiver as
WIEGAND or RELAY
Add the tag s/n to the memory ( individually or by blocks )
Delete the tags ( single, by blocks, by list, all tags
Add remote controls to the memory
Delete remote controls from the memory (can be done
individually, only one button, by blocks, by list, or all Tx )
Set the interval time or dead time ( see proper chapter)
Configure the operating mode of the relays and the settings of
the Wiegand signal
Makes a backup of the memory to an external memory device or
restores the database from an external memory device
Gives information about types of outputs, No. of Tx or Tags, and
current firmware version
Password
P1: scroll up
P3: conrm/enter
P4: exit
When the antenna installation is complete, it is necessary to determine whether the interface device must activate the
relays or simply sends, in Wiegand, the serial numbers of the tags.
Relay output: The serial numbers of the tags must be stored (see “Add Card”). the memory can hold up to 7560
cards;
Wiegand output: if the interface device is connected to an access control panel through the Wiegand bus, pairing
the cards is not necessary and therefore there is no memory limit. However, if the SELECTIVE OPERATION MODE
is set, the memorization of a single tag will affect the Wiegand communication, so only tags where the s/n has been
memorized will be allowed to pass.
Furthermore, if the installation requires the use of Erone Keeloq remote controls, which will be decoded by the built-in
receiver, the remote controls must be memorized. The memory contains 100 transmitters.
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
EN
6
Press button P3 for
4 seconds to enter
Programming menu

14 Add Tag [ Single ]
m e n u
A d d T a g
A d d T a g
W a i t
0 0 0 0 0 0 0 0
Show the Tag to the reader
15 Add Tag [ Block ]
For adding a block of tags ( card, plate, sticker ) enter the option “Add Tag” of the main menu and “Add Tag Block”.
m e n u
A d d T a g
A d d T a g
B l o c k
Type the number of tag to memorize
H o w m a n y
T a g ? 0 0 0 0
1 0 0 0 T a g ?
N o Y e s
Confirm ( P1 for shift and P3 to confirm)
W a i t
0 0 0 0 0 0 0 0
Show the Tag to the reader
16 Delete Tag [ Single ]
For deleting a tag ( card, car-plate, sticker ) enter the option “Add Tag” of the main menu and “Delete Tag”.
m e n u
D e l T a g
D e l e t e
T a g
W a i t
0 0 0 0 0 0 0 0
Show the Tag to the reader
0 1 3 2 0 7 8 ?
N o Y e sConfirm ( P1 for shift and P3 to confirm
The memorization of even a single tag, enables the SELECTIVE OPERATING MODE. This mode means that
from that time on, the interface device filters and sends on Wiegand only the serial numbers of stored tags, and
the memory is limited to 7560 tags.
To operate without any filter, with unlimited memory, it is necessary to delete all memorized tags from the memory.
For adding a tag ( card, plate, sticker ) enter the option “Add Tag” of the main menu and “Add Tag again”.
EN
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
www.erone.com - www.cdvigroup.com 7
Type the S/N of the tag : enter the number using P1 or P2, shift
left with P4
Type the S/N of the tag : enter the number using P1 or P2, shift
left with P4
Type the S/N of the tag : enter the number using P1 or P2, shift
left with P4

17 Delete Tag [ Multiple ]
For deleting many tags you can do it by block, selecting them from a list, or delete the full memory.
m e n u
D e l T a g
D e l e t e
T a g
D e l e t e
B l o c k
D e l e t e
B y l i s t
D e l e t e
A l l T a g s
P o s : 0 0 0 5
0 0 0 0 0 1 2 3
C o n f i r m ?
N o Y e s
Confirm ( P1 for shift
and P3 to confirm
W a i t
0 0 0 0 0 0 0 0
Type the S/N of the tag :
enter the number using
P1 or P2, shift left with P4
Show the Tag
to the reader
Type the number of tags to delete
H o w m a n y
T a g ? 0 0 0 0
1 0 0 T a g ?
N o Y e s
P1 for shift and P3 to confir
W a i t
0 0 0 0 0 0 0 0Type the S/N of the tag : enter the number
using P1 or P2, shift left with P4
Show the Tag
to the reader
C o n f i r m ?
N o Y e s
Confirm ( P1 for shift
and P3 to confirm
18 Add Tx
m e n u
A d d T x
A d d t o
R e l a y 1
A d d t o
R e l a y 2
A d d T x
A d d
B l o c k
W a i t
0 0 0 0 0 0 0 0 Type the S/N of the Tx : enter the number
using P1 or P2, shift left with P4
Press any button of the Tx to add or
Type the number of Tx to add
H o w m a n y
T x ? 0 0 0
W a i t
0 0 0 0 0 0 0 0 Type the S/N first Tx of the block
Press the button of the first Tx of the block
same as Relay 1
W a i t
0 0 0 0 0 0 0 0 Type the S/N of the Tx : enter the number
using P1 or P2, shift left with P4
Press any button of the Tx to add or
Once entered the S/N, in case of output “Relay”, the system will make
the following association:
button A --> Relay 1
button B --> Relay 2
ATTENTION: The memorization of a single Transmitter (Tx), enables the SELECTIVE OPERATING MODE.
This mode means that from the time that first Tx is memorized, the interface device filters and sends on Wiegand
only the serial numbers of memorized Tx (Limit of 100 TX )
Add RF transmitters to the memory ( up to 100 )
NOTE: If the output
set is “Wiegand”, the
sw ignores the
choices “Add to
Relay” .
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
EN
8

19 Del Tx
20 Single or Double Reader Architecture
The connection shown below can be done with 1 or 2 readers connected on RS-485 to the same interface unit. Each
reader is pre-programmed with a unique RS-485 address. The interface automatically assigns the right value to the
parameter “Address” The default value of this parameter is 000. During the installation, the first time a UHF card is
read, the system changes the default value assigning the address of the activated antenna.
RS-485
1
250
251
W1
Wiegand
Access
control
system
RS-485
124
124
W1
Wiegand
Access
control
system
Example 1 : Single reader conguration Example 2 : Double reader conguration
Delete RF transmitters from the memory ( single or multiple
Type the S/N of the Tx : enter the number
using P1 or P2, shift left with P4
Press any button of the Tx to delete or
Press P1 to add a Button and P2 to delete it,
confirm with P3, shift back with P4
Press any button of the Tx to delete
Press P1 to scroll the list and P3 to confirm
Type the S/N of the Tx : enter the number
using P1 or P2, shift left with P4
m e n u
D e l T x
D e l e t e
T x
D e l e t e
B l o c k
D e l e t e
b y L i s t
W a i t
0 0 0 0 0 0 0 0
D e l e t e
A l l T x
W a i t
0 0 0 0 0 0 0 0
P o s : 0 0 0 5
0 0 0 0 0 1 2 3
C o n f i r m ?
N o Y e s
C o n f i r m ?
N o Y e s
EN
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
www.erone.com - www.cdvigroup.com 9
In a double reader installation, the system assigns “Address 1” to the
parameter as the address of the first reader activated ( 250 ) and likewise
assigns “Address 2” to the parameter as the address of the second reader
activated, assigning the value 251.

m e n u
S e t t i n g s
S e t t i n g s
I n t e r v a l
S e t t i n g s
D e a d T i m e
S e t t i n g s
A n t e n n a
A n t e n n a 1
A d d r e s s
A d d r e s s 1
001
A n t e n n a 1
C o d e
W i e g a n d 1
1
A n t e n n a 1
P o w e r
P o w e r 1
3 0
A n t e n n a 1
B u z z e r
B u z z e r 1
O N
RS-485
Wiegand (*)
1
RS-485
2
250
251
00051
00099
W1
W2
Wiegand
Access
control
panel
Example 3 : Double reader and double interface conguration
21
NOTE: the manual assignment of the parameters for Address1 and Address2 is necessary in case of replacement of
the antenna as the automatic assignment takes place only if the parameter is 000, factory setting.
(*) : Despite having a dierent wiegand address, it is advisable to use dierent input ports on the access control to avoid overlaps
caused by simultaneous activations.
In case of more interfaces connected to an Access Control Panel, it is necessary to assign each a dierent address , which will
be sent on the bus wiegand ( see par.25). This is done by setting the parameter “Code” on the menu Settings to each device. The
factory wiegand address is 1.
Settings
Sets the interval time between 2 next trains of bits
carrying the S/N of the tag detected by the reader,
as long as the tag stands in the eld generated by
the UHF reader.
Values available : [0, 5, 10, 20, 30 Sec.]
Set the “deadtime” that is the time in which a tag,
once carried out, must remain outside the detec-
tion eld to be detected again.
Avaliable values [0, 1, 2, 3, 4, 5, 6, 7, 8 , 9 Sec.]
AHU49
UHF READER
INSTALLATION MANUAL
EN
10
I n t e r v a l
1 0
D e a d T i m e
5
Set the address of the reader [1 - 254]
on RS-485. See the sticker on the
reader or make the reading of a card
Set the address of the interface [1 - 9]
on bus Wiegand ( see par. 25)
Set the transmitting power of the
reader. Power settings control the
detection range of the UHF reader. See
table at left of this page. (Detection
range may be affected by obstacles in
the detection area)
Enable/disable the buzzer of the
reader while detecting the tag

Set the release time of
the relay after the first
activation: use P1,P2 to
increase the values, P3
to confirm and shift left,
P4 to shift back
If the output is “Wiegand”, set the Wiegand protocol ( 26, 30 or 44 bit ) and a filter on the Tx
buttons If the output is “Relay” set the operating mode of the 2 relays as Pulse, Step, Timed or
Disabled) Set a filter for the Wiegand signal: this means
that a signal is generated only if the button of the
transmitter being used has been properly set.
Example: A - - D , means that the Wiegand
signal will be generated only if buttons A or D are
set and if buttons B or C are used no signal is
generated
22 Cong
m e n u
C o n f i g
C o n f i g
R e l a y 1
C o n f i g
R e l a y 2
R e l a y 1
P u l s e
R e l a y 1
S t e p
R e l a y 1
T i m e d
R e l a y 1
D i s a b l e d
hh m m s s
0 0 : 0 0 : 0 0
See Relay 1
W i e g a n d
B i t
B i t
2 6 B i t
W i e g a n d
F i l t e r
F i l t e r
A - - D
E d i t T X
N # 0 0 1
P o s 0 0 1
1 2 3 4 5 6 7 8
R e l a y 1
A B - -
R e l a y 2
-- - D
C o n f i r m
N o Y e
s
Set the buttons that activate the 2 relays
EN
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
www.erone.com - www.cdvigroup.com 11
21 Settings ( continue)
S e t t i n g s
A n t e n n a
D e l e t e
S e t t i n g s
A n t e n n a 2
A d d r e s s
A d d r e s s 2
001
A n t e n n a 2
C o d e
W i e g a n d 2
1
A n t e n n a 2
P o w e r
P o w e r 2
3 0
A n t e n n a 2
B u z z e r
B u z z e r 2
O N
Sets the receiver to the factory defaults.
Enable/disable the buzzer of the
reader 2 while detecting the tag
Set the transmitting power of the reader 2.
Power settings control the detection range
of the UHF reader. See table at left on
page 10. (Detection range may be affected
by obstacles in the detection area)
Set the address of the reader 1 [1 - 254]
on RS-485. See the sticker on the reader
or make the reading of a card
Set the address of the interface [1 - 9]
on bus Wiegand ( see par. 25)
R S 4 8 5
B a u d r a t e
B a u d r a t e
1 15 2 0 0
B u z z e r
E n a b l e
B u z z e r
O N
Set the communication baud-rate of
the bus RS485
Enable/disable the buzzer of the Receiver

Button Code
A 1010
B 1011
C 1100
D 1101
25.2 Wiegand S/N of the radio transmitters
Bit 1 Bit 2 - 5 Bit 10 - 25 Bit 26
Even Parity ( 1 bit ) [ 4 bit Button ] (*) [ 20 bit S/N ] Odd Parity ( 1 bit )
Wiegand 26Wiegand 26
Wiegand 30Wiegand 30 Bit 1 Bit 2 - 5 Bit 6 - 29 Bit 30
Even Parity ( 1 bit ) [ 4 bit Button ] (*) [ 24 bit S/N ] Odd Parity ( 1 bit )
(*) Code of the 4 buttons of a transmitter
expressed in hex format, according to
the table :
24 Wiegand Output
The I/F - receiver converts in Wiegand format both the S/N of the tags UHF and the S/N of the radio transmitters
Erone keeloq. The architecture of the Wiegand signal is different according to the number of bits set ( 26, 30 or 44
bit ).
Bit 1 Bit 2 - 5 Bit 6 - 25 Bit 26
Even Parity ( 1 bit ) [ 4 bit Address ] (*) [ 20 bit S/N ] Odd Parity ( 1 bit )
25.1 Wiegand UHF
WWiegand 26iegand 26
Wiegand
Wiegand 44Wiegand 44
(**) Longitudinal Redundancy Check
Bit 1 Bit 2 - 5 Bit 6 - 29 Bit 30
Even Parity ( 1 bit ) [ 4 bit Address ] [ 24 bit S/N ] Odd Parity ( 1 bit )
Bit 1-4 Bit 5 - 8 Bit 9 - 16 Bit 17 - 40 Bit 41 - 44
0000 ( xed ) [ 4 bit Address ] 00000000 [ 24 bit S/N ] LRC (**)
(*) Is the address of the receiver set in the Settings submenu ( see par. 21)
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
EN
12
The Backup function allows saving the full internal data-base into an external memory device or the restoration of
the data-base from an external memory device
1) 1) Plug-in the memory into the connector as shown below
2) Enter the backup menu and select the option desired.
ATTENTION: Restoring the database from an external
memory device will overwrite all data in the internal memory at
the time of the restoration.
USB thumb drive – 512 Kb minimum
23 Backup
Backup
to
Backup
from
Menu
Backup
!
Wiegand 44Wiegand 44 Bit 1-4 Bit 5 - 8 Bit 9 - 16 Bit 17 - 40 Bit 41 - 44
0000 ( xed ) [ 4 bit Address ] 00000000 [ 24 bit S/N ] LRC (**)
(**) Longitudinal Redundancy Check

Info
Output
Info
N. Tags
Info
N. Tx
Tag
List
Tx
List
Info
Version
Menu
Info
Displays the current setting for the output : Relay or Wiegand.
•If the output is “Relay”, specifies the operating mode set for the 2 relays
•If the output is “Wiegand” the protocol in use : 26, 30 or 44 bits
Shows the Number of Tags memorized out of the max available ( 7680 )
25 Info
Shows the number of Transmitter memorized out of 100
( max )
Shows the list of the tags and their memory position
( useful if you need to delete the list)
Shows the list of the transmitters and their memory position
( useful if you need to delete the list )
Shows current Firmware version
EN
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
www.erone.com - www.cdvigroup.com 13
26 Password
The receiver manages 2 different passwords: ADMIN and SERVICE and their use can be activated or deactivated.
The receiver is supplied with the password disabled.
The 2 factory passwords are:
Password Admin = 11111,
Password Service = 00000.
By entering the Admin password Admin you are allowed to access the submenu that allows the activation,
deactivation and modification of passwords.
NOTE: By entering the Service password you can access the main menu but cannot make any password changes.
Incorrect Password: If you type an incorrect password 5 times, the ID number of the receiver appears on the display:
By pressing P3 again, an 8-digit unblocking code (PUK) is requested. To obtain the PUK code, send an email to
[email protected] or call (866) 975-0101.Once the PUK code is set, the password returns to the factory
default value.
SYSTEM N
12345678
PUK
Password
ADMIN
Password
SERVICE
Password
DISABLE
Passw.?
Exit
Password
Menu
Password

27 Installation of UHF Card tags
Vehicles without metalized windshields allow the choice of one of the six positions shown on the figure below (A - F)to
install the UHF tag.
Vehicles with pre-configured metalized windshields should have a reserved area that is not metalized for RFID tags so
choose position B.
A
B
C
F E D
For optimum performance:
•Choose position A or F if the reader is located to the left of your vehicle.
•Choose position C or D if the reader is to the right of your vehicle.
•Choose position B or E if the antenna is in the overhead, above your vehicle
PLEASE NOTE : If your windshield is metalized, the read range of the reader will be affected. Please test the
read range before installing the UHF tag.
Rearview mirror
Steering wheel
Card or cardholder
TAG
Reader
Reader
TAG
TAG
TAG
DOLCWIUHF-ER-902
UHF READER
INSTALLATION MANUAL
EN
14

Direction of
trac ow
Direction of
trac ow
Vehicle Sensor
Loop
Exit loop
Exit loop
Reader
Reader
Gate
Gate
Tag read
zone
Tag read
zone Readers should be
at least 14ft. 5in apart
28 Parking garage application
EN
INSTALLATION MANUAL
15
29 Hand-held cards
Hold the card with your arm outstretched and away from your body. If the card is held near to your body, the
detection will be significantly decreased. A card in a wallet or a pocket may not be detected.
The best position of the reader can be searched, in the first step holding the card by hand.
PLEASE NOTE: The card is very sensitive and card detection can change greatly depending
on how the card is presented to the reader. Refer to the images Below to understand the best
way to hold the card.
Vehicle Sensor
Loop
DOLCWIUHF-ER-902
UHF READER

Declaration of Conformity
Transmitter Solutions hereby declares that the radio equipment type AHU49 complies with the Standard 47 CFR
FCC Part 15, subpart B
32
IS-AHU49 Rev.0 on 4/9/2023
30 Installation of UHF stickers AT49.TS / AT49P.TS
The sticker position placement should be similar to the placement of the card tag, as described in Section 27
above. It is best to apply to the surface of a vehicle’s windshield or headlights.
IMPORTANT: UHF stickers are thin and fragile. Once applied, they cannot be removed and reused, so please
test the performance and detection of the tag in different locations to see what works best before installation.
31 IInstallation of the License plate Tag PT49.TS
Apply only to a vehicle’s license plate. Use screws to fix the tag on the bottom edge of the license plate.
Please test to ensure performance before installing
INSTALLATION MANUAL
EN
The warranty period for this product is 24 months, beginning from the manufacturer date.
During this period, if the product does not work correctly, due to a defective component, the product will be repaired or
substituted at our discretion.
This guarantee does not cover the integrity of the plastic container..
Any service after the sale is supplied at the factory.
34 Warranty
Any changes or modifications to this equipment not expressly approved by the Transmitter Solutions could void the
user’s authority to install and operate this equipment and may void the product warranty.
Transmitter Solutions
2505 Chandler Avenue, Suite, 1
Las Vegas, NV 89120 -
(866) 975-0101 - (866) 975-0404 Fax
33 Notice
DOLCWIUHF-ER-902
UHF READER
Table of contents
Other Transmitter Solutions IP Access Controllers manuals