MicRadar R60AFD2 User manual

Biosensing radar
60GMilimeterwave
MicRadar Technology (Shenzhen) Co. ,LTD
Please read the product instructions carefully and keep them
properly before use V1.0

R60AFD2-Fall detection tuya WiFi application manual
1
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
Contents
1. Step 2 of the equipment distribution routine 12
1.Device distribution routine steps
1、Download through the app store: Tuya Smart APP
2、Press and hold the button on the product until the LED light

R60AFD2-Fall detection tuya WiFi application manual
2
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
is off and then release when it flashes. At this time, the
radar resets and enters the network distribution mode. There
are two ways to configure the network:
(Note: The phone needs to be connected to 2.4Gwifi, not 5Gwifi)
Method 1 (Bluetooth):
The App interface will pop up "Discover the device to be added:
1". After clicking to add,the app will automatically connect
the device to the network.
Method 2 ( Wi-Fi ):
Click the "red plus sign" in the upper right corner of the APP
interface to enter the product category selection page, click
the upper right
Click "Auto Discovery" in the corner to search for the device,
and click "Next" after the device is found.

R60AFD2-Fall detection tuya WiFi application manual
3
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
Fill in the relevant wifi information and click "Next" to
configure the device.
3、Wait for the APP to configure the wifi network until the
network configuration is successful,then the Tuya wifi radar
device can be successfully connected.
2.APP panel interface introduction

R60AFD2-Fall detection tuya WiFi application manual
5
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
3.60G fall radar application scenarios and function
introduction
1.60G fall radar installation scenario restrictions:
The fall radar is suitable for indoor bathrooms, kitchens,
bedrooms and other scenarios
·It is necessary to avoid fans, etc., which will vibrate
and rotate metals within the radar detection range
The installation method of the fall radar is inclined wall
installation
2. The main function points of 60G fall radar:
· Someone/Nobody Status Judgment
· Active/Still/Stateless Judgment

R60AFD2-Fall detection tuya WiFi application manual
6
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
· Fall alarm status judgment
· Static parking alarm status judgment
4.60G fall radar main function detailed description
1. Judgment of fall alarm status:
Fall alarm test:
When a person falls and lies on the ground within the radar fall
detection range, a fall judgment is made, and a fall alarm status is
reported when a more detailed judgment is made within 5s and the
conditions are confirmed.
Perform fall action tests such as
"inside fall" and "side fall" within
the fall detection range, and do not
get up for a certain period of time
after falling on the ground
When the radar status is from none
- "fall down alarm
Record Radar Fall Alarm Triggered
Successfully
If it can be triggered normally, it
means "pass"
Example test table format:
Testing frequency
Whether to trigger a fall
alarm
pass
the first time
Yes
pass
To deactivate the fall alarm test:
When the fall detection range of the radar has triggered the fall alarm,
and the person gets up and leaves, the radar will immediately release the
fall alarm state and display no fall state.
On the premise that the fall alarm
state has been triggered within the
range, get up and leave to release
the fall alarm test
When the radar status changes from
fall alarm -> none
Recorded radar fall alarm
successfully removed

R60AFD2-Fall detection tuya WiFi application manual
7
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
If it can be removed normally, it
means "pass"
Example test table format:
Testing frequency
Whether to cancel the fall
alarm
pass
the first time
Yes
pass
2. Judgment of static parking alarm status:
Stationary parking alarm test:
When a person is stationary for 5 minutes within the detection range
of the radar stationary parking alarm, the stationary parking alarm
state is reported.
Simulate a person to stand still for
5 minutes within the range to
perform a static resident alarm test
When the radar state is never -
"Stationary Parking Alarm"
Record radar stationary parking
alarm successfully triggered
If it can be triggered normally, it
means "pass"
Example test table format:
Testing frequency
Whether the static parking
alarm is normally triggered
pass
the first time
Yes
pass
Releasing the stationary parking alarm test:
When the stationary parking alarm has been triggered within the radar
stationary parking detection range, and the person gets up and leaves,
the radar will immediately release the stationary parking alarm state
and display the stationary parking state status No.

R60AFD2-Fall detection tuya WiFi application manual
8
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
On the premise that the static
parking alarm state has been
triggered within the range, get up
and leave to release the static
parking alarm test
When the radar state is parked from
stationary to alarm -> none
Recorded radar stationary parking
alarm successfully released
If it can be removed normally, it
means "pass"
Example test table format:
Testing frequency
Is it normal to cancel the
stationary parking alarm?
pass
the first time
Yes
pass
3. Judgment of someone/nobody status:
No Time Test:
When there is no one in the radar detection range, the radar will detect
whether there is no human movement, breathing and other actions within
the range for a period of time, and output the unmanned state when it is
confirmed that there is no one. (It is normal to enter the unmanned state
within 1 minute of normal environment)
Test with default sensitivity
leave the radar detection area
There are no people moving around in
the environment and no interference
from sources of interference
start the timer
When the radar status changes from
someone to still - "no one stops for
a moment
Recording radar into dead time
Less than or equal to provide data
means "pass"
Example test table format:
Testing
frequency
scene mode
into no man's
time
pass
the first time
toilet scene
40s
pass
Trigger distance test:

R60AFD2-Fall detection tuya WiFi application manual
9
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
When a person within the radar detection range enters the trigger,
the radar will instantly display the presence status.
Switch between different scene
modes for testing
Trigger range according to
different scene modes
Keep approaching the radar at a
speed of at least 0.7m/s
When the radar state changes from no
one - "someone stops for a moment
Record the distance to the radar
Compare and verify with the
corresponding data provided
Greater than or equal to provide
data means "pass"
Example test table format:
Testing
frequency
scene
mode
Test
direction
document
data
(radius)
real data
(radius)
pass
the first
time
default
scene
The long
side
3 m
2.9 m
pass
Sitting distance test:
When the person within the radar detection range remains stationary, the
radar will continue to display the stationary state of the person.
Test based on sensitivity "7"
Facing the Radar Sit Test within
the Radar Sit Detection Range
5min per test
sit still at the corresponding
distance
Record whether the radar can keep the
occupant state after sitting for 5
minutes
If it can keep the state of people for
5 minutes, it means "pass"
Example test table format:
Testing
frequency
scene mode
Test
direction
document
data
(radius)
real data
(radius)
pass
the first
time
toilet
scene
The long
side
2 m
1.95 m
pass

R60AFD2-Fall detection tuya WiFi application manual
10
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
4. Active/static/stateless judgment:
Active state test:
When the tester continuously walks or continues to make large movements
in the detection area of the fall radar, the active state will be output
(“static state” triggers “active state” response time ≤ 1s)
Within the detection range of the
selected scene mode
Keep walking or keep making big
moves
Judging radar status
Radar status when in motion
Can output "active" status means
"passed"
Example test table format:
Testing
frequency
Whether the
status is
responsive
Status response
time
pass
the first time
Yes
≤1s
pass
Static state test:
When the tester is still in the detection area of the fall radar, or when
the person just leaves the unmanned environment without entering the
unmanned state, the static state will be output (the "active state"
triggers the "static state" response time of 3s)
Within the detection range of the
selected scene mode
keep still
Judging radar status
Radar status when in motion
Can output "calm" state means "pass"
Example test table format:
Testing
frequency
Whether the
status is
responsive
Status response
time
pass
the first time
Yes
3s
pass
Stateless testing:

R60AFD2-Fall detection tuya WiFi application manual
11
501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen
When the detection area is unmanned, the radar will output the unmanned
state after a certain period of time judgment.
Leaving the detection range of the
selected scene mode
No trigger, no interference, keep
for a certain period of time after
entering the unmanned state
Judging radar status
When the radar state
Can hold "None" status means "Pass"
Example test table format:
Testing frequency
Whether the status is
responsive
pass
the first time
Yes
pass
5.Historical version update instructions
Revision
Release Data
Summary
Author
V1.0_0606
2022/6/6
first draft
OF_Frank
Other manuals for R60AFD2
1
Other MicRadar Radar manuals
Popular Radar manuals by other brands

JRC
JRC JMA-9132-SA quick start guide

Furun
Furun FAR-2827 FAR-2127 Operator's manual

ATS
ATS Axsis SC-300H Operation and reference manual

Decatur Electronics
Decatur Electronics Genesis VP Directional user manual

kymati
kymati KY-RAY 3D.03.01 user manual

Endress+Hauser
Endress+Hauser PROFIBUS PA Levelflex FMP50 operating instructions

Dahua
Dahua DHI-ITSJC-2302-DC12 user manual

Sports Radar
Sports Radar SR3600 instruction manual

Endress+Hauser
Endress+Hauser Hart Micropilot FMR60B operating instructions

JRC
JRC Radar 3000 instruction manual

HYDROLOGICAL SERVICES
HYDROLOGICAL SERVICES HYC 230 manual

Endress+Hauser
Endress+Hauser Micropilot FMR63B PROFIBUS PA technical information