1
ANI-F-IC1
Multi-Format ANI Encoder
Manual Revision: 2007-06-20
Covers So tware Revisions:
ANI-F: 1.0 & Higher
SPECIFICATIONS
Operating Voltage 5 VDC
Operating Current 2.6 mA
Operating Temperature -30 - 60 C
Frequency Range 280-3600 Hz
PTT Output Current 200 mA
Audio Output Level 1V RMS
Audio Output Impedance 10KΩ/22 KΩ
Tone Distortion <1%
GENERAL INFORMATION
The ANI-F offers ANI & Emergency ANI encoding
tone signaling formats such as Motorola’s MDC-
1200 & MDC-600, M/A-Com’s G-Star, DTMF, 5-
tone, 2-tone, ANI with Status, or Burst Tone. A
special POCSAG paging version is also available.
The ANI-F can be used with Midian’s CAD or DDU
Series products for monitoring ANI and ENI
transmissions.
PRODUCT PROGRAMMING
Midian’s ANI-M Icom Series Products are
programmed using the KL-3 programmer and IPI-1.
Please reference the KL-3 & IPI-1 manuals for setup
instructions of the programming software and
hardware. From the product selection screen on the
KL-3 UP software, select the appropriate product
name from the list and click OK.
Set the parameters of the ANI-F-IC1 software to fit
the application. If any clarifications on a feature are
required, move the mouse cursor over the feature
name until the question mark appears and right
click, a definition of the feature will be shown. If 2-
tone or custom tones will be used in the ANI-F-IC1,
you will need to select “Enable Advanced ANI Tone
Definitions” in the “ANI Tone Definitions” tab.
After entering the parameters, save the file by going
to File - Save As. Enter the file name in the File
Name block and click Save. Saving the file will allow
for quick and easy reprogramming of units.
Plug the ANI-F-IC1 onto the Icom Programming
Interface and plug the interface into the KL-3.
To program the ANI-F-IC1 push the button on the
Icom Programming Interface click “Program Unit” in
the menu bar to send the file to the ANI-F-IC1. The
LED on the interface will flash indicating
programming is complete. Follow the same
procedure to read the unit, but select “Read Unit” in
the menu bar.
HARDWARE INSTALLATION
Be certain to follow standard anti-static procedures
when handling any of Midian’s products.
F-3/F-4: Plug the unit into the options connector
located behind the rubber stopper under the battery.
Before plugging the unit in, remove W1 to open the
radio’s PTT path, if common PTT is not being used.
F-3G/F-4G: Plug the unit into the options connector
located behind the rubber stopper under the battery.
Before plugging the unit in, open the radio’s PTT
path by opening jumper D, if common PTT is not
being used.
F-14/F-24: The unit plugs into the options connector
under the battery. Before plugging the unit in, open
jumper PTT to open the radio’s PTT path, if common
PTT is not being used.
F-30/F-40: The unit plugs into the options connector
located on the main board. Before installing the unit,
open the radio’s PTT path by opening jumper CPB,
if common PTT is not being used. It will be
necessary to open the radio for installation. This
radio uses a negative PTT; therefore, you will need
to open J1 on the ANI-F-IC1.
F-30G/F-40G: The unit plugs into the first options
connector (labeled as Option One) located on the
main board. Before installing the unit, open the
radio’s PTT path by opening jumper G, if common
PTT is not being used. It will be necessary to open
the radio for installation. This radio uses a negative
PTT; therefore, you will need to open J1 on the ANI-
F-IC1.
2
F-33G/F-43G: The unit plugs into the options
connector under the battery. Before plugging the
unit in, open jumper D to open the radio’s PTT path,
if common PTT is not being used.
F-120/220: The unit plugs into the options connector
located on the main board. Before installing the unit,
open the radio’s PTT path by opening the PTT
jumper on the front PC board located next to the
PTTI and PTTO pads. This jumper is listed as CP2
on the schematic of the radio. Only open the PTT
path if common PTT is not being used. This radio
uses a negative PTT; therefore, you will need to
open J1 on the ANI-F-IC1.
F-320/420/520/620: The unit plugs into the options
connector located on the main board. Before
installing the unit, open the radio’s PTT path by
opening PTT jumper C, if common PTT is not being
used. This radio uses a negative PTT; therefore,
you will need to open J1 on the ANI-F-IC1.
F-1020/2020: The unit plugs into the options
connector located on the main board. Before
installing the unit, open the radio’s PTT path by
opening jumper PTT, if common PTT is not being
used. This radio uses a negative PTT; therefore,
you will need to open J1 on the ANI-F-IC1.
F-1720/1820: The unit plugs into the options
connector located on the main board. Before
installing the unit, open the radio’s PTT path by
opening jumper PTT, if common PTT is not being
used. This radio uses a negative PTT; therefore, you
will need to open JU-1 on the ANI-F-IC1.
HARDWARE ALIGNMENT
For the TX Audio Output in a wide band system, set
the ANI modulation pot R12 to 3.3 KHz (66% of 5
KHz) of deviation per EIA specifications. For the TX
Audio Output in a narrow band system, set the ANI
modulation pot R12 to 1.65 KHz (66% of 2.5 KHz) of
deviation per EIA specifications.
RADIO PROGRAMMING
F-3/F-4/F-30/F-40/F-320/F-420/F-1020/F-2020: For
Emergency ANI, program the radio’s option button
(P0-P3) as Opt 1 Momentary/Active Low.
F-3G/F-4G/F-14/F-24/F-33G/F-43G/F-120/F-220/F-
520/F-620/F-1720/F-1820: For Emergency ANI,
program the radio’s option button under Common >
Key & Display as OPT1 Momentary/L (Active Low).
F-30G/F-40G: For Emergency ANI, program the
radio’s option button under Common>Key & Display
as OPT11 Momentary/L (Active Low). If you use the
second options connector, program as OPT21
Momentary/L (Active Low).
OPERATION
ANI Encode: When the PTT Input is grounded, the
unit will assert the PTT Output and send the
programmed ANI tones out the TX Tone Output.
ENI Encode: When the Emergency Input is
grounded, the unit will assert the PTT Output and
send the programmed Emergency ANI tones out the
TX Tone Output.
TECHNICAL NOTES
Programming 2-tone: 2-tone ANI is programmed
with the Advanced Tone Defintions. In Frame 1,
Frequency 1 type in the frequency of the first tone
and type the length of the first tone in Frame 1
msec. In Frame 2 msec, type in the length of the
gap time. In Frame 3, Frequency 1 type in the
frequency of the second tone and type the length of
the second tone in Frame 3 msec.
F-30G/F-40G: It has been found on more recent
versions of the radio that the PTT In and PTT Out
connections on the options connector have been
reversed. In these versions, the PTT jumper should
not be cut and functions such as Time-Out-Timer
and Penalty Timer will not be available.
MIDIAN CONTACT INFORMATION
Midian Electronics Inc.
2030 N. Forbes Blvd. #101
Tucson, Arizona 85745 USA
Orders: 1-800-MIDIANS
Phone: 520-884-7981
Fax: 520-884-0422
E-mail: [email protected]
Web: http://www.midians.com/

Other Midian Media Converter manuals

Midian VS-110-IC1 Operating and maintenance instructions

Midian

Midian VS-110-IC1 Operating and maintenance instructions

Midian VAE-10 User manual

Midian

Midian VAE-10 User manual

Midian TT-9 User manual

Midian

Midian TT-9 User manual

Midian CAD-POCSAG User manual

Midian

Midian CAD-POCSAG User manual

Midian VAE-80 User manual

Midian

Midian VAE-80 User manual

Midian UED-1 Series User manual

Midian

Midian UED-1 Series User manual

Midian PDE-1 User manual

Midian

Midian PDE-1 User manual

Midian VAE-1-VX1 User manual

Midian

Midian VAE-1-VX1 User manual

Midian BTD-2 MOD-1272 Addendum User manual

Midian

Midian BTD-2 MOD-1272 Addendum User manual

Midian CAD-100 User manual

Midian

Midian CAD-100 User manual

Midian RT-2 User manual

Midian

Midian RT-2 User manual

Midian ANI-F-VX Series User manual

Midian

Midian ANI-F-VX Series User manual

Popular Media Converter manuals by other brands

ALFAtron ALF-SUK4 manual

ALFAtron

ALFAtron ALF-SUK4 manual

TRENDnet TFC-1000S10D3 Specifications

TRENDnet

TRENDnet TFC-1000S10D3 Specifications

Cirrus Logic CS5530 manual

Cirrus Logic

Cirrus Logic CS5530 manual

Wisenet SPD-150 Quick manual

Wisenet

Wisenet SPD-150 Quick manual

Jensen JBS-225 user manual

Jensen

Jensen JBS-225 user manual

CYP EL-6010-4K22 Operation manual

CYP

CYP EL-6010-4K22 Operation manual

Kramer VM-4Hxl user manual

Kramer

Kramer VM-4Hxl user manual

Beijing Aiterfeixiang Technologies HEV-10W user manual

Beijing Aiterfeixiang Technologies

Beijing Aiterfeixiang Technologies HEV-10W user manual

Kiloview E3 user manual

Kiloview

Kiloview E3 user manual

TTI TIA-3000 operating instructions

TTI

TTI TIA-3000 operating instructions

Ikegami IEN-10 instruction manual

Ikegami

Ikegami IEN-10 instruction manual

Ocean Optics ADC1000-USB operating instructions

Ocean Optics

Ocean Optics ADC1000-USB operating instructions

Danfoss VLT HVAC Drive FC 102 installation guide

Danfoss

Danfoss VLT HVAC Drive FC 102 installation guide

SEC America 680 CE owner's manual

SEC America

SEC America 680 CE owner's manual

LGB 55024 user manual

LGB

LGB 55024 user manual

EuroLite Node 8 user manual

EuroLite

EuroLite Node 8 user manual

Arcom Solo Neo instruction manual

Arcom

Arcom Solo Neo instruction manual

Christie Phoenix Quad-T quick start

Christie

Christie Phoenix Quad-T quick start

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.