Mighty Mule FM138 User manual

WARNING
WARNING
!
SENSOR with 50, 100 or 150
feet of Direct Burial Cable Warning Signs (2)
Wire Nuts (2)
Battery Connection Wires (2)
Double Spade
Connectors (2)
Ty-Wraps (4)
Wire Clamp
!
WARNING
GATE OPENING
SENSOR IN USE
The Automatic Gate Opener is activated when a
vehicle comes within range of the sensor buried
along side the driveway and could possibly be
activated by a child on a bicycle, tricycle or other
metal play equipment.
Parts Identication:
EXIT WAND
Installation Manual
WARNING
When an EXIT WAND is in use, the automatic gate opener could be
activated by a child on a bicycle or other metal play equipment. This
Product is not recommended for applications exposed to children.

2
• The SENSOR is designed to detect iron-
based metal in motion.
• The SENSOR’s ability to detect iron-based
metal objects is based on the mass, velocity
and proximity of the object to the sensor.
EXAMPLE - A child’s bicycle moving at
2 mph @ 1’ from the sensor has a similar
effect as a car moving at 2 mph @ 6’ from
the sensor.
• The SENSOR must be stationary to function
properly.
Gate Opener
Control Box
Driveway
RANGE:
12 ft. radius
(max)
SENSOR:
2 ft. from Driveway (max)
and12 in. deep
Open Gate
Outside Sensor
Range
( allow 5 ft. for wiring
to Control Box)
Gate Opener
Control Box
12”
Minimum of 25 feet
SENSOR: 2 feet from
driveway edge and
1 foot in ground
Open Gate
Outside Sensor
Range
PVC conduit in ground
and up to control box
recommended 24”
1. Obtain the instruction manual for the gate
opener.
2. Locate the control terminals (2) that will ONLY
OPEN the gate.
3. Verify that the above inputs when shorted
(a small wire connecting the 2 terminals) will
do all of the following:
• OPEN the gate if the gate is idle.
• STOP and then OPEN the gate if gate is
closing.
• DO NOTHING if the gate is opening.
BLACK
BLUE
RELAY OUTPUT
POWER INPUT = 11-30 Vdc or 8-26 Vac
RED
Braided
Ground
WAND
WIRING TO OPEN ONLY
INPUT OF GATE
OPENER CONTROL
Normally open relay contacts, closes for 2
seconds when moving vehicle is detected.
+
–
IMPORTANT
DO NOT CONNECT THE POWER
INPUT WIRES TO THE POWER
SOURCE (i.e. 12 V battery) UNTIL
INSTRUCTED TO DO SO.
INSTALLATION OVERVIEW
WIRING THE WAND
YELLOW

3
4. Connect the BLACK to the terminal labeled
COMMON, and the BLUE wire to terminal in
STEP 3 to open gate. See wiring diagrams to
the right for guidance on wiring the sensor to your
gate opener’s control board.
5. Connect the POWER INPUT wires from the
Exit Wand Sensor (if not already connected to a
terminal on the board).
• Connect the YELLOW and BRAIDED
GROUND wires to the (–) NEGATIVE side of
power source (i.e. battery).
• Connect the RED wire to the (+) POSITIVE
side of power source (i.e. battery).
TURN GATE OPENER OFF
Connect the BLACK
wire from the SENSOR
CABLE to one of the
COMMON terminals on
the opener control board.
Connect the RED
wire from the SENSOR
CABLE to the AUX V+
terminal on the opener
control board.
Connect the YELLOW
wire and BRAIDED GROUND
wire from the SENSOR
CABLE to the AUX V- terminal
on the opener control board.
Connect the BLUE
wire from the SENSOR
CABLE to the EXIT
terminal on the opener
control board.
BLUE
RED YELLOW + BRAIDED
BLACK
RECR
GRN
BLK
RED
EXIT
SAFETY
EDGE
CYCLE
COMMON
LINK
Connect the
BLUE wire from
the SENSOR
CABLE to the
EXIT terminal on
the opener
control board.
Connect the RED
wire from the
SENSOR CABLE
to the H AUX OUT
terminal on the
opener board.
Connect the BLACK
wire, YELLOW wire and
BRAIDED GROUND
wire from the SENSOR
CABLE to one of the
COMMON terminals on
the opener control board.
BLUE
BRAIDED
YELLOW
BLACK
AUX
OUT SOLAR
INPUT
18VAC/
H L
RECEIVER
ALM
RCVR.
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
CONTROL INPUTS
CLOSE
EDGE
Connect the BLUE wire from
the SENSOR CABLE to the
EXIT terminal on the opener
control board.
Connect the BLACK wire
from the SENSOR CABLE
to one of the COMMON
terminals on the opener
control board. BLUE
BLACK
See the diagram to the left for battery connection instructions
for the RED, YELLOW AND BRAIDED GROUND wires.
WIRING DIAGRAM EXAMPLES
NOTE: Power Input Connections Not Shown.
(See gate instruction manual for complete instructions)
BRAIDED GROUND
from SENSOR Cable
YELLOW wire from
SENSOR CABLE
RED wire from SENSOR Cable
Battery Cable
BLACK (-)
BLACK BATTERY CONNECTION WIRE
with Spade Connector included with SENSOR
RED BATTERY CONNECTION WIRE
with Spade Connector included
with SENSOR
Double Spade Connectors
included with SENSOR
Battery Cable
RED (+)
VAR5
K1
PF1
K2
BATT +
K3
K4
VAR4
VAR3
VAR2
VAR1
SFTY.
EXIT
CYCLE
EDGE
SENSOR
COMMON
LOCK+
LOCK–
WHT
GRN
RED
BLK
WHT
GRN
SECOND OPR.FIRST OPR.
RED
BLK
14 VAC
OR
SOLAR
Connect the BLUE wire from
the SENSOR CABLE to the
EXIT terminal on the opener
control board.
Connect the RED wire from the
SENSOR CABLE to the LOCK+
terminal on the opener control
board.
Connect the BLACK wire,
YELLOW wire and BRAIDED
GROUND wire from the
SENSOR CABLE to one of the
COMMON terminals on the
opener control board.
BLUE
RED
BRAIDED
YELLOW
BLACK
Connect the BLUE wire from
the SENSOR CABLE to the
EXIT terminal on the opener
control board.
Connect the BLACK wire, YELLOW wire and BRAIDED GROUND
wire to one of the COMMON terminals on the opener control board.
Connect the
RED wire from
the SENSOR
CABLE to the
LOCK+ terminal
on the opener
control board.
POWER
CHGR
CHGR
EDGE
CYCLE
EXIT
SAFETY
COM
COM
LOCK+
LOCK -
BLUE
BLACK BRAIDED
YELLOW
IMPORTANT
WHEN THE WAND IS FIRST POWERED
UP IT MUST BE UNDISTURBED FOR 60
SECONDS TO PERFORM THE SELF TEST
AND CALIBRATIONS. BEFORE POWERING
THE WAND MAKE SURE THERE ARE NO
MOVING METAL OBJECTS OR MOVING
VEHICLES WITHIN THE RANGE OF
THE WAND
6. Turn opener ON and TEST.

TECHNICAL SPECIFICATIONS:
TROUBLESHOOTING: Make sure all connections are correct
• Disconnect the power (battery) to the WAND.
• Reconnect the power to the WAND and make sure that no metal object or vehicle is moving
around the WAND for 60 seconds while it is calibrating.
• Test the WAND to verify that it is working properly.
This product and
any accessory you
purchase should only
be installed on a gate opener that
meets the current safety standard,
UL325. If you have a gate opener
that is not listed with the current
standard please contact NSC sales
department for consultation on a
gate opener that can meet your
specic needs.
LIMITED ONE YEAR WARRANTY
Nortek Security & Control, LLC (NSC), accessories are warranted by the manufacturer against defects in materials and manufacturer
workmanship for a period of one (1) year from date of purchase, provided the recommended installation procedures have been followed.
In the case of product failure due to defective material or manufacturer workmanship within the one (1) year warranty period, the product
will be repaired or replaced (at the manufacturer’s option) at no charge to the customer, if returned freight prepaid to NSC, 5919 Sea
Otter Place, Carlsbad, CA. 92010. IMPORTANT: Call (800) 543-1236 for a Return Goods Authorization (RGA) number before returning
accessory to factory. Products received at the factory without an RGA number will not be accepted. Replacement or repaired parts are
covered by this warranty for the remainder of the one (1) year warranty period or six (6) months, whichever is greater.
NSC will pay the shipping charges (equal to United Parcel Service GROUND rate) for return to the owner of items repaired under
warranty.
The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair, or for
the reinstallation of those parts after repair. This warranty shall be considered void if damage to the product(s) was due to improper
installation or use, connection to an improper power source, or if damage was caused by electrical power surge or lightning, wind, re,
ood, insects or other natural agent.
After the one (1) year warranty period, NSC will make any necessary repairs for a nominal fee. Call NSC at (800) 543-1236 for more
information. This warranty gives you specic legal rights, and you may also have other rights which may vary from state to state. This
warranty is in lieu of all other warranties, expressed or implied. NOTE: Verication of the warranty period requires copies of receipts
or other proof of purchase. Please retain these records.
Converting Metric Units to English Equivalents
When You Know Multiply by To Find Symbol
Centimeters 0.3937 Inches in. ( “)
Meters 3.2808 Feet ft. ( ‘)
Kilograms 2.2046 Pounds lb. (#)
Converting English Units to Metric Equivalents
When You Know Multiply by To Find Symbol
Inches 2.5400 Centimeters cm
Feet 0.3048 Meters m
Pounds 0.4535 Kilograms kg
Converting Temperature
deg. Celsius (ºC x 1.8) + 32 deg. Fahrenheit ºF
deg. Fahrenheit (ºF-32) ÷ 1.8 deg. Celsius ºC
Conversion Chart
• Power Supply: 8-26 Vac - 11-30 Vdc
• Current consumption 3 mA. typical
• Relay rating: 1 amp max, 30 Vdc
• Relay Pulse Time: 2 seconds
• Operating Temperature: 25°F (-4°C) to 125°F
(69°C), or battery operating temperature
• Dimensions: 1¾” (44.5 mm) diameter x 16½”
(42cm) long
10032597 Rev-A
©2021 Nortek Security & Control LLC. All rights reserved.
Mighty Mule is a registered trademark of Nortek Security & Control LLC.
Mighty Mule Sales: 800-543-4283 |Mighty Mule Technical Support: 800-543-1236 Mon-Fri 8am - 7pm EST • Saturday 10am - 6:30pm EST
5919 Sea Otter Place, Carlsbad, CA, 92010
For more information on Mighty Mule’s full line of Automatic Gate Operators, Gate Openers and Access Controls visit
www.mightymule.com
Other Mighty Mule Accessories manuals