manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MiLAN
  6. •
  7. Media Converter
  8. •
  9. MiLAN MIL-C2114 Series User manual

MiLAN MIL-C2114 Series User manual

Installation Guide: MIL-C2114 Series
MT-RJ - Type
Connector
LEDs RJ-45
Connector
•
•
•
•
•
•
•
•
•.
•
•
Regulatory Approval
Canadian EMI Notice
European Notice
Trademarks
To Contact MiLAN Technology
FCC Class A
UL 1950
CSA C22.2 Number 950
EN60950
CE
- EN55022 Class B
- EN50082-1
This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada.
Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage
Directive (73/23/EEC) issued by the commission of the European Community Compliance with these directives
implies conformity to the following European Norms:
EN55022 (CISPR 22) - Radio Frequency Interference
EN50082-1 (IEC801-2, -3, -4) - Electromagnetic Immunity
EN60950 (IEC950) - Product Safety
Five-Year Limited Warranty
MiLAN Technology warrants to the original consumer or purchaser that each of it’s products, and
all components thereof, will be free from defects in material and/or workmanship for a period of
five years from the original factory shipment date. Any warranty hereunder is extended to the
original consumer or purchaser and is not assignable.
MiLAN Technology makes no express or implied warranties including, but not limited to, any
implied warranty of merchantability or fitness for a particular purpose, except as expressly set
forth in this warranty. In no event shall MiLAN Technology be liable for incidental or
consequential damages, costs, or expenses arising out of or in connection with the performance
of the product delivered hereunder. MiLAN Technology will in no case cover damages arising
out of the product being used in a negligent fashion or manner.
© 2000 MiLAN, the MiLAN logo and MiLAN Technology are either trademarks or registered
trademarks of Digi International, Inc. in the United States and/or other countries. All other
trademarks are the property of their respective holders.
For prompt response when calling for service information, have the following information ready:
Product serial number and revision
Date of purchase
Vendor or place of purchase
You can reach MiLAN Technology technical support at:
E-mail: [email protected]
Telephone: +1.408.744.2751
Fax: +1.408.744.2771
MiLAN Technology
1299 Orleans Drive
Sunnyvale, CA 94089-1138
United States of America
Telephone: +1.408.744.2775
Fax: +1.408.744.2793
http://www.milan.com
[email protected]
© Copyright 2000 MiLAN Technology Printed in the USA P/N: 90000211 Rev. A
The MIL-C2114 comes equipped with a MT-RJ type connector
and supports Fast Ethernet in both half and full-duplex mode.
For network budget constraint, the MIL-C2114 uses 150 nano-
seconds (approximately 30 meters of cable) during conversion in
each direction.
To maximize the fiber cable distance, use one meter of CAT 5 UTP
cable when connecting directly to a node (subject to fiber budget of
16 dBm and collision domain restrictions). In full-duplex environments,
use up to 100m of CAT 5 UTP and:
2 Km of multi-mode optical fiber for MIL-C2114;
15 Km of single-mode optical fiber for MIL-C2114-15.
Figure 1. Inside of the MIL-C2114
Link Sentry Configuration
The Link Sentry feature on the MIL-C2114 is configured through
a 4-position DIP switch (refer to Figure 1).
Default setting for the DIP switches: All switches are in the “up”
Position.
Link Sentry allows users to add new management tools to the network.
When enabled, it monitors the selected receiver port and, if the Link
test signal is not seen, the unit will stop sending a signal through the
selected transmit port.
The following table shows which Link Sentry feature is enabled.
Table 1. Link Sentry Features
1 (down) Fiber port Fiber port
2 (down) UTP port UTP port
3 (down) UTP port Fiber port
4 (down) Fiber port UTP port
MDI-X/MDI
Switch
RJ-45 Female
Connector
Connector
4
3
2
1
LEDs
4-pin DIP Switch
MDI-X MDI
1234568
7
Pin 1=RX+
Pin 2=RX-
Pin 3=TX+
Pin 6=TX-
Pin 1=TX+
Pin 2=TX-
Pin 3=RX+
Pin 6=RX-
Switch Losing Link on RX of Stop sending Link on TX of
Figure 2. RJ-45 Pinouts
Note: For two MIL-C2114s used back-to-back and UTP-to-UTP,
all DIP switches must be enabled in the “down” position on the first
MIL-C2114. On the second MIL-C2114, set switches 1 and 4 in the
“down” position.
To enable Link Sentry with two MIL-C2114s used back-to-back and
fiber-to-fiber, enable all DIP switches in the “down” position on the
first MIL-C2114. On the second MIL-C2114, enable switches 2 and 3
in the “down” position.
MT-RJ Type
Installation
1. Attach a UTP cable from the network to the RJ-45 port.
(Use screened UTP cabling for CISPR 22 class B installation.)
2. Cross-connect the fiber cables: Attach both fiber cables
TX to RX and RX to TX from the fiber network cabling to the
ST-type connectors on the MIL-C2114.
3. Apply power to the unit:
A. Insert the power adapter’s receptacle into the power plug.
B. Insert the power adapter into a wall outlet.
Diagnostic LEDs and Conditions Indicated
There are five LEDs, including power and:
•
•
•
•
•
•
•
•
TX/ACTIVE: Receiving packets from the 100BASE-TX port.
FX/ACTIVE: Receiving packets from the 100BASE-FX port.
TX/LINK: An active connection on the 100BASE-TX port.
FX/LINK: An active connection on the 100BASE-FX port.
MDI-X/MDI Switch
The MDI-X/MDI switch allows for quick configuration
of the 100BASE-TX port. Cables used when the switch is
in the MDI-X position (the “left” position:
For a hub/repeater, use a swap cable (pins are
connected 1 to 3, 2 to 6, 3 to 1, and 6 to 2).
For a workstation/PC, use a straight-through cable
(pins are connected 1 to 1, 2 to 2, 3 to 3, and 6 to 6).
Cables used when the switch is in the MDI position (the
“right” position):
For a hub/repeater, use a straight-through cable (pins
are connected 1 to 1, 2 to 2, 3 to 3, and 6 to 6).
For a workstation/PC, use a swap cable (pins are
connected 1 to 3, 2 to 6, 3 to 1, and 6 to 2).
Multi-mode fiber
•
•
•
•
1300nm wavelength
62.5/125 micron diameter
-14 dBm launch power
-31 dBm receive sensitivity
Single-mode fiber (15Km)
•
•
•
•
1300nm wavelength
9/125 micron diameter
-8 dBm launch power
-31 dBm receive sensitivity

Other MiLAN Media Converter manuals

MiLAN MIL-C2112 User manual

MiLAN

MiLAN MIL-C2112 User manual

MiLAN MIL-C2414 Series User manual

MiLAN

MiLAN MIL-C2414 Series User manual

MiLAN MIL-9200X User manual

MiLAN

MiLAN MIL-9200X User manual

MiLAN MIL-C1411 User manual

MiLAN

MiLAN MIL-C1411 User manual

MiLAN MIL-140 User manual

MiLAN

MiLAN MIL-140 User manual

MiLAN MIL-185C User manual

MiLAN

MiLAN MIL-185C User manual

MiLAN MIL-S341X User manual

MiLAN

MiLAN MIL-S341X User manual

MiLAN MIL-9100X User manual

MiLAN

MiLAN MIL-9100X User manual

MiLAN MIL-C2000 User manual

MiLAN

MiLAN MIL-C2000 User manual

MiLAN MIL-C1111 User manual

MiLAN

MiLAN MIL-C1111 User manual

MiLAN MIL-225C User manual

MiLAN

MiLAN MIL-225C User manual

MiLAN Raven MIL-RC6113LX User manual

MiLAN

MiLAN Raven MIL-RC6113LX User manual

MiLAN MIL-C2413 Series User manual

MiLAN

MiLAN MIL-C2413 Series User manual

MiLAN MIL-185C User manual

MiLAN

MiLAN MIL-185C User manual

MiLAN MIL-4750 User manual

MiLAN

MiLAN MIL-4750 User manual

MiLAN MIL-160T User manual

MiLAN

MiLAN MIL-160T User manual

MiLAN Raven MIL-RC3112 User manual

MiLAN

MiLAN Raven MIL-RC3112 User manual

MiLAN MIL-1225LS User manual

MiLAN

MiLAN MIL-1225LS User manual

MiLAN MIL-GBIC-LX10 Instruction Manual

MiLAN

MiLAN MIL-GBIC-LX10 Instruction Manual

MiLAN MIL-C2113 Series User manual

MiLAN

MiLAN MIL-C2113 Series User manual

MiLAN MIL-140CRM User manual

MiLAN

MiLAN MIL-140CRM User manual

MiLAN MIL-S3110 User manual

MiLAN

MiLAN MIL-S3110 User manual

MiLAN MIL-100s User manual

MiLAN

MiLAN MIL-100s User manual

MiLAN MIL-C2412 User manual

MiLAN

MiLAN MIL-C2412 User manual

Popular Media Converter manuals by other brands

Enerpac NSC Operation and maintenance manual

Enerpac

Enerpac NSC Operation and maintenance manual

Plexim PLECS RT Box manual

Plexim

Plexim PLECS RT Box manual

Adcom RD-230 quick start guide

Adcom

Adcom RD-230 quick start guide

DVDO High Definition Video Processor & Hub Edge Setup guide

DVDO

DVDO High Definition Video Processor & Hub Edge Setup guide

Danfoss 176F4170 installation guide

Danfoss

Danfoss 176F4170 installation guide

Miranda KS-900 Guide to installation and operation

Miranda

Miranda KS-900 Guide to installation and operation

eks EL-100XS manual

eks

eks EL-100XS manual

SEW-Eurodrive CMP40 operating instructions

SEW-Eurodrive

SEW-Eurodrive CMP40 operating instructions

Bustec ProDAQ 3411 user manual

Bustec

Bustec ProDAQ 3411 user manual

Atlona AT-HD610 user manual

Atlona

Atlona AT-HD610 user manual

Briteq DS12 Operation manual

Briteq

Briteq DS12 Operation manual

Konig KN-HDMICON26 manual

Konig

Konig KN-HDMICON26 manual

Comtech EF Data CIC-50 Installation and operation manual

Comtech EF Data

Comtech EF Data CIC-50 Installation and operation manual

Expert EX-9132C-2 Operation manual

Expert

Expert EX-9132C-2 Operation manual

TMB ProPlex IQ Micro user manual

TMB

TMB ProPlex IQ Micro user manual

HEIDENHAIN ERN 1385 Mounting instructions

HEIDENHAIN

HEIDENHAIN ERN 1385 Mounting instructions

ETarh Technology ETH-500 user manual

ETarh Technology

ETarh Technology ETH-500 user manual

Lindy 42845 user manual

Lindy

Lindy 42845 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.