Schematic/Electrical Parts
SINGLE STAGE PRESS
MP1540, MP1550, MP1601,
MP1602, MP1603, MP1604,
MP1650, MP1A50, and MP1A03
PELLERIN MILNOR CORPORATION POST OFFICE BOX 400, KENNER, LOUISIANA 70063-0400, U.S.A.
Table of Contents
ME6PM1S1AE/15352A
Page Description Document
1 Component Parts List W6PM1SPL/2015184N
9 Limited Standard Warranty BMP720097/2008272A
10 How to Get the Necessary Repair Components BIUUUD19/20081231
11 Milnor Allied Interface Specifications and Signals, Single Stage
Press BICALC02P1/20031016
20 How to Use Milnor® Electrical Schematic Diagrams BIUUUK01/20130308
32 Sample Schematic BMP010012/2001503N
34 Wiring Safety Fence Gate Interlocks BISUUI02/20070507
36 Customer Safety Gate Interlock W6SYSSG/2007192B
38 3 Phase Motor Connection Diagram BMP850029/1999362B
39 3P Motor Diagram-Multivolt W80008/2001253A
40 Control Box Layout W6PM1STG1/2012235B
42 Allied Interface 8088 Processor W6PM1SAI/1998051B
44 Allied Interface 186 Processor W6PM1SAIA/2003174B
46 Board To Board Wiring 8088 Processor W6PM1SBW/1999061B
48 Board to Board Wiring for 08BSPE2T W6PM1SBWA/2015205B
50 Board to Board Wiring for 08BSPE3T W6PM1SBWB/2015352B
52 Serial Display W6PM1SD/1997311B
54 Press Dry Contact Data Pass W6PM1SDP2/1998101B
56 Press Dry Contact Data Pass 8088 Processor W6PM1SDP3/1998101B
58 Press Dry Contact Data Pass 186 Processor W6PM1SDP3A/2003174B
60 Press Dry Contact Data Pass-Weight W6PM1SDP4/2004492B
62 Flat Panel Graphic Display W6PM1SEC/2007285B
64 Control Circuit Transformer W6PM1SHV/1999526B
66 Inputs (Sheet 1) 8088 Processor W6PM1SI1/2003325B
68 Inputs (Sheet 1) 186 Processor W6PM1SI1A/2004454B
70 Inputs (Sheet 1) 186 Processor - Soft Squeeze W6PM1SI1B/2004433B
72 Inputs (Sheet 2) 8088 Processor W6PM1SI2/2015205B
74 Inputs (Sheet 2) 186 Processor W6PM1SI2A/2015205B
76 Keypad W6PM1SKP/1999267B
78 Mk VI 30 Button Keypad W6PM1SKPA/2007285B
80 Discharge Light Curtain W6PM1SLC/2014252B
82 Motors and Incoming Power W6PM1SMTR/2015184B
84 Inverter belt motor wiring W6PM1SMTRA/2014252B
86 Non Storage Belt Behind Press W6PM1SOP/2011414B
88 Pivoting Coinc W6PM1SPC1/2010143B
90 Press Pump Interface W6PM1SPP/2012235B
92 Press Pump Interface w/ conductivity probes W6PM1SPP1/2013114B
94 3-Wire & Signal W6PM1SS+/2015205B
Table of Contents, continued
ME6PM1S1AE/15352A
Page Description Document
96 Soft Squeeze W6PM1SSQ/2011452B
98 Electrical Valves MkV only W6PM1SVS/2014252B
100 Electrical Valves Mk VI - Spray Ring W6PM1SVSA/2014252B
102 Electrical Valves Mk VI - Soft Squeeze W6PM1SVSB/2014252B
C O M P O N E N T P A R T S L I S T W6PM1SPL/2015184N
COMPONENT FUNCTION OF THIS WHERE TO FIND
NUMBER COMPONENT NUMBER THIS COMPONENT MILNOR P/N DESCRIPTION LOCATION
>>>COMPONENT LOCATION DETAILS
01 DETAIL-INPUTS AND OUTPUTS W6PM1STG1 B2TAG98010 SINGLE STAGE PRESS IN/OUTPUTS CONTROL BOX
02 DETAIL-AIR VALVES W6PM1STG1 B2TAG98011 SINGLE STAGE PRESS AIR VALVES VALVE BOX
03 DETAIL-PROCESSOR BOX W6PM1STG1 B2TAG98002 SINGLE STAGE PRESS PROCESSOR PROCESSOR BOX
04 DETAIL-CONTROL BOX W6PM1STG1 B2TAG98001 SINGLE STAGE PRESS CONTROL TAG CONTROL BOX
BA >>>PRINTED CIRCUIT BOARDS
BAD-1 BOARD- A TO D CONVERTER W6PM1SBW 08BSADCT BD:SERIAL A-D CONVERT->TEST CONTROL BOX
BAD-1 BOARD- A TO D CONVERTER W6PM1SBWA 08BSADCT BD:SERIAL A-D CONVERT->TEST CONTROL BOX
BBB-1 BOARD-RAM BATTERY BACKUP W6PM1SBW 08BSBB1T BOARD: SER BATT BACKUP-TEST PROCESSOR BX
BBB-1 BOARD-RAM BATTERY BACKUP W6PM1SBWA 08BSBB1T BOARD: SER BATT BACKUP-TEST PROCESSOR BX
BDA-1 BOARD-HI RES D TO A #1 W6PM1SBW 08BSDACHT BD:HI-RES SERIAL D-A->TEST CONTROL BOX
BDA-1 BOARD-HI RES D TO A #1 W6PM1SBWA 08BSDACHT BD:HI-RES SERIAL D-A->TEST CONTROL BOX
BDFP DISPLAY-10.4 FLAT PANEL W6PM1SEC 08EFD320C DISPLAY 10.4FP/DCUL7/INVERTER
BDVFD DISPLAY-MICROPROCESSOR IF 8088 PROC. W6PM1SD 08BSEVFD5U SERIAL VFD 2LINE 9600B-TEST SWITCH PANEL
BDVFD DISPLAY-MICROPROCESSOR IF 186 PROC. W6PM1SD 08BSEVFD5V BD:SER VFD.2LINE-19200B-TEST SWITCH PANEL
BFPC BOARD-COLOR FLAT PANEL CONTROLLER W6PM1SEC 08EFD320C DISPLAY 10.4FP/DCUL7/INVERTER SWITCH PANEL
BFPI BOARD-COLOR FLAT PANEL INTERFACE W6PM1SEC 08BSEDIFAT BD:FP LCD DRVR/INV INTERFACE>TEST SWITCH PANEL
BIO-1 BOARD-8 OUTPUT/16INPUT #1 W6PM1SBW 08BS816CT BD:SERIAL 8OUT-16INPUT-TEST CONTROL BOX
BIO-1 BOARD-8 OUTPUT/16INPUT #1 W6PM1SBWA 08BS816CT BD:SERIAL 8OUT-16INPUT-TEST CONTROL BOX
BIO-2 BOARD-8 OUT/16IN #2 (DATA PASS) W6PM1SBW 08BS816CT BD:SERIAL 8OUT-16INPUT-TEST CONTROL BOX
BIO-2 BOARD-8 OUT/16IN #2 (DATA PASS) W6PM1SBWA 08BS816CT BD:SERIAL 8OUT-16INPUT-TEST CONTROL BOX
BIO-3 BOARD-8OUT/16IN #3 (DATA PASS) W6PM1SBW 08BS816CT BD:SERIAL 8OUT-16INPUT-TEST CONTROL BOX
BIO-3 BOARD-8OUT/16IN #3 (DATA PASS) W6PM1SBWA 08BS816CT BD:SERIAL 8OUT-16INPUT-TEST CONTROL BOX
BIO-4 BOARD-8OUT/16IN #4 (DATA PASS) W6PM1SBWA 08BS816CT BD:SERIAL 8OUT-16INPUT-TEST CONTROL BOX
BMTH BOARD-5 CARD MOTHER W6PM1SBW 08BS5MTHAT BD:SERIAL 5 CARD MOTHER-TEST CONTROL BOX
BMTH BOARD-8 CARD MOTHER W6PM1SBWA 08BS8MTHAT BD:SERIAL 8 CARD MOTHER-TEST CONTROL BOX
BO24-1 BOARD-24 OUTPUT #1 W6PM1SBW 08BSO24AT BD:SERIAL 24 OUTPUT->TEST CONTROL BOX
BO24-1 BOARD-24 OUTPUT #1 W6PM1SBWA 08BSO24AT BD:SERIAL 24 OUTPUT->TEST CONTROL BOX
BPB BOARD-8088 PROCESSOR W6PM1SBW 08BSPDT 8088 PROCESSOR ->TESTED PROCESSOR BX
BPB BOARD-186 PROCESSOR W6PM1SBWA 08BSPE2T PROC BD+FP->TEST PROCESSOR BX
BPC-1 BOARD-PROPORTIONAL VALVE CONTRL W6PM1SBW 96RH708A3T ELE AMPLIFIER CARD-PRESS+TAG CONTROL BOX
BPC-1 BOARD-PROPORTIONAL VALVE CONTRL W6PM1SBWA 96RH708A3T ELE AMPLIFIER CARD-PRESS+TAG CONTROL BOX
BWPS BOARD:WATER SENSOR PROBES W6PM1SI2 08BNWPST WATER PROBE SENSOR BD-TEST CONTROL BOX
Page 1 of 8
1
C O M P O N E N T P A R T S L I S T W6PM1SPL/2015184N
BWPS BOARD:WATER SENSOR PROBES W6PM1SI2A 08BNWPST WATER PROBE SENSOR BD-TEST CONTROL BOX
CB >>>CIRCUIT BREAKERS
CBPRD CIRCUIT BREAKER-PRESS RETURN PUMP W6PM1SMTR 09FTB016T OVERLOAD PROTECTOR ADJ. 10-16 CONTROL BOX
CBFAN1 CIRCUIT BREAKER-DOOR FAN W6PM1SMTR 09FTB010T OVERLOAD PROTECTOR ADJ.6.3-10 CONTROL BOX
CP >>>PHOTOEYES
CPCBL PHOTOEYE-COINC IS LOADED W6PM1SI2 09RPE011 PHOTOEYE VALU-BEAM 10-30DC ON COINC
CPCBL PHOTOEYE-COINC IS LOADED W6PM1SI2A 09RPE011 PHOTOEYE VALU-BEAM 10-30DC ON COINC
CR >>>RELAY-PILOT OR CONTROL
CR100 RELAY-LOWEST RAM PRESSURE W6PM1SSQ 09C024D37 4PDT "KH" 110/120V SOFT SQUEEEZE BX
CR250 RELAY-SECOND LOWEST RAM PRESSURE W6PM1SSQ 09C024D37 4PDT "KH" 110/120V SOFT SQUEEEZE BX
CRCBL RELAY-COINC LOADED W6PM1SPC1 09C024D37 4PDT "KH" 110/120V CONTROL BOX
CRD RELAY-DISCHARGE END EYE BLOCKED W6PM1SPC1 09C024D37 4PDT "KH" 110/120V CONTROL BOX
CRFLH RELAY-PRESS RETURN TANK HIGH W6PM1SPP1 09C024D24 RELAY 4PDT DIFGLD 14PIN 24V CONTROL BOX
CRFLL RELAY-PRESS RETURN TANK LOW W6PM1SPP1 09C024D24 RELAY 4PDT DIFGLD 14PIN 24V CONTROL BOX
CRGC RELAY-GOODS AT THE END OF THE BELT W6PM1SI1 09C024D37 4PDT "KH" 110/120V CONTROL BOX
CRGC RELAY-GOODS AT THE END OF THE BELT W6PM1SI1A 09C024D37 4PDT "KH" 110/120V CONTROL BOX
CRGC RELAY-GOODS AT THE END OF THE BELT W6PM1SI1B 09C024D37 4PDT "KH" 110/120V CONTROL BOX
CRH RELAY-COINC AT HOME POSITION W6PM1SPC1 09C024D37 4PDT "KH" 110/120V CONTROL BOX
CRN RELAY-NORMAL RAM PRESSURE W6PM1SSQ 09C024D37 4PDT "KH" 110/120V SOFT SQUEEEZE BX
CRPRB RELAY-RUN PIVOTING COINC BELT W6PM1SPC1 09C024D37 4PDT "KH" 110/120V CONTROL BOX
CRRB RELAY-RUN PIVOTING COINC BELT W6PM1SPC1 09C024D37 4PDT "KH" 110/120V CONTROL BOX
CRS+ RELAY-START W6PM1SS+ 09C024D37 4PDT "KH" 110/120V CONTROL BOX
CS >>>CONTACTOR-MOTOR STARTER
CSA CONTACTOR-COINC BELT CONTACTOR W6PM1SPC1 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSCRB CONTACTOR-COINC BELT W6PM1SVS 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSCRB CONTACTOR-COINC BELT W6PM1SVSA 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSCRB CONTACTOR-COINC BELT W6PM1SVSB 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSFAN1 CONTACTOR-DOOR FAN W6PM1SS+ 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSFAN2 CONTACTOR-HOOD FAN W6PM1SS+ 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSFAN3 CONTACTOR-HOOD FAN W6PM1SS+ 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSHP(MP16xx-
H
CONTACTOR-HYDRAULIC PUMP HIGH VOLT W6PM1SS+ 09MC08G337 37A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSHP(MP16xx-
L
CONTACTOR-HYDRAULIC PUMP LOW VOLT W6PM1SS+ 09MC08L337 60A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSHP(MP1Axx-
H
CONTACTOR-HYDRAULIC PUMP HIGH VOLT W6PM1SS+ 09MC08L337 60A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSHP(MP1Axx-
L
CONTACTOR-HYDRAULIC PUMP LOW VOLT W6PM1SS+ 09MC08U337 180A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSPRP CONTACTOR-PRESS RETURN PUMP W6PM1SMTR 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
Page 2 of 8
2
C O M P O N E N T P A R T S L I S T W6PM1SPL/2015184N
CSRBF CONTACTOR-RUN BELT FORWARD W6PM1SVS 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSRBF CONTACTOR-RUN BELT FORWARD W6PM1SVSA 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSRBF CONTACTOR-RUN BELT FORWARD W6PM1SVSB 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSRBR CONTACTOR-RUN BELT REVERSE W6PM1SVS 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSRBR CONTACTOR-RUN BELT REVERSE W6PM1SVSA 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSRBR CONTACTOR-RUN BELT REVERSE W6PM1SVSB 09MC08B337 12A 3P MCS CONT NR 120V5/6 CONTROL BOX
CSRC CONTACTOR-RECIRC. AND COOLING FAN W6PM1SS+ 09MC08C337 16A 3P MCS CONT NR 120V5/6 CONTROL BOX
EB >>>AUDIBLE SIGNALS
EBSG BUZZER-OPERATOR SIGNAL W6PM1SS+ 09H015 BUZZ/115V W6-32 CTR+6"LEADS SWITCH PANEL
EC >>>COUNTERS
ECC COUNTER-CYCLE W6PM1SVS 38C201 NONRESETABLE COUNTER 115VAC CONTROL BOX
ECC COUNTER-CYCLE W6PM1SVSA 38C201 NONRESETABLE COUNTER 115VAC CONTROL BOX
ECC COUNTER-CYCLE W6PM1SVSB 38C201 NONRESETABLE COUNTER 115VAC CONTROL BOX
EF >>>FUSE OR FUSE HOLDER
EF1 FUSE-CONTROL CIRCUIT PRIMARY-L1 W6PM1SHV 09FF005AWN FUSE #KTK 5A600V=HPS HOLDER CONTROL BOX
EF2 FUSE-CONTROL CIRCUIT PRIMARY-L2 W6PM1SHV 09FF005AWN FUSE #KTK 5A600V=HPS HOLDER CONTROL BOX
EF37 FUSE-CONTROL CIRCUIT SECONDARY W6PM1SHV 09FF006AMA FUSE BK/ABC 6 AMP 250V BUSS CONTROL BOX
EFF1 FUSE-DOOR FAN L1 W6PM1SMTR 09FF002AWN FUSE BUSS #KTK 2 1/2 AMP 600V CONTROL BOX
EFF2 FUSE-DOOR FAN L2 W6PM1SMTR 09FF002AWN FUSE BUSS #KTK 2 1/2 AMP 600V CONTROL BOX
EL >>>LIGHT-PILOT OR INDICATOR
ELM LIGHT-ROTATING BEACON W6PM1SPC1 09H025V37 BEACON ROTARY 5.5"DIA AMBER TOP OF PRESS
ELPRP LIGHT-PRESS RETURN PUMP RUNNING W6PM1SPP 09J060A37 LAMP 1/2" AMB 250V IDI 1051QC3 SWITCH PANEL
ELPRP LIGHT-PRESS RETURN PUMP RUNNING W6PM1SPP1 09J060A37 LAMP 1/2" AMB 250V IDI 1051QC3 SWITCH PANEL
ELPTT LIGHT-PRESS RETURN PUMP DID NOT RUN W6PM1SPP 09J060A37 LAMP 1/2" AMB 250V IDI 1051QC3 SWITCH PANEL
ELPTT LIGHT-PRESS RETURN PUMP DID NOT RUN W6PM1SPP1 09J060A24 LAMP 1/2" AMB IDI #1090QC3-28V SWITCH PANEL
ELSG LIGHT-OPERATOR SIGNAL W6PM1SS+ 09J060WH37 LAMP 1/2" WHITE 120V TAB SWITCH PANEL
ELSGF LIGHT-SIGNAL (FLASHING) W6PM1SS+ 09H025V37 BEACON ROTARY 5.5"DIA AMBER TOP OF PRESS
ES >>>ELECTRONIC POWER SUPPLIES
ESPS POWER SUPPLY-MICROPROCESSOR W6PM1SBW 08PSS3401T 40 WATT POWER SUPPLY TESTED CONTROL BOX
ESPS POWER SUPPLY-MICROPROCESSOR W6PM1SBWA 08PSS3401T 40 WATT POWER SUPPLY TESTED CONTROL BOX
ET >>>OVERLOADS
ETCRB OVERLOAD-COINC BELT W6PM1SMTR 09FTD0037T E1 PLUS OL RELAY 3.2-16A CONTROL BOX
ETFAN1 OVERLOAD-DOOR FAN W6PM1SMTR 09FTD0010T EI PLUS OL RELAY 1.0-5.0A CONTROL BOX
ETFAN2 OVERLOAD-HOOD FAN W6PM1SMTR 09FTD0010T EI PLUS OL RELAY 1.0-5.0A CONTROL BOX
ETFAN3 OVERLOAD-HOOD FAN W6PM1SMTR 09FTD0010T EI PLUS OL RELAY 1.0-5.0A CONTROL BOX
Page 3 of 8
3
C O M P O N E N T P A R T S L I S T W6PM1SPL/2015184N
ETHP(MP16xx-
H
OVERLOAD-HYDRAULIC MOTOR HIGH VOLT W6PM1SMTR 09FTD0121T E1 PLUS OL RELAY 9-45A CONTROL BOX
ETHP(MP16xx-
L
OVERLOAD-HYDRAULIC MOTOR LOW VOLT W6PM1SMTR 09FTD0230T E1 PLUS OL RELAY 18-90A CONTROL BOX
ETHP(MP1Axx-
H
OVERLOAD-HYDRAULIC MOTOR HIGH VOLT W6PM1SMTR 09FTD0230T E1 PLUS OL RELAY 18-90A CONTROL BOX
ETHP(MP1Axx-
L
OVERLOAD-HYDRAULIC MOTOR LOW VOLT W6PM1SMTR 09FTD0040T OL RELAY 40-200A AB #193-EEJF CONTROL BOX
ETPRP OVERLOAD-PRESS RETURN PUTM W6PM1SMTR 09FTD0037T E1 PLUS OL RELAY 3.2-16A CONTROL BOX
ETRB OVERLOAD-BELT MOTOR W6PM1SMTR 09FTD0037T E1 PLUS OL RELAY 3.2-16A CONTROL BOX
ETRC OVERLOAD-RECIRC AND COOLING FAN W6PM1SMTR 09FTC0016T OL RELAY 1.6-5.0A AB#193-A3E1 CONTROL BOX
EX >>>TRANSFORMERS
EX37 TRANSFORMER-200/240VAC-120VAC W6PM1SHV 09U500AA37 XFMR 200-240VPRI 120VSEC 500VA CONTROL BOX
EX37 TRANSFORMER-380/480VAC-120VAC W6PM1SHV 09U500AAB XFMR MULTIVOLT 500VA-5PRI LEAD CONTROL BOX
EX37 TRANSFORMER-600VAC-120VAC W6PM1SHV 09U500AA98 XFMR 600V PRI 120VSC 500VA CONTROL BOX
EXFHV TRANSFORMER350-480VAC-240VAC W6PM1SMTR 09U050AAB XFMR MULTIVOLT 500VA(5PRI LDS) CONTROL BOX
KB >>>KEYBOARDS
KBMP KEYPAD-MICROPROCESSOR W6PM1SKP 08ND0206N KEYPAD-DOME=2X5 MATRIX NUME. SWITCH PANEL
KBMP KEYPAD-MICROPROCESSOR W6PM1SKPA 08ND5X6GC KEYPAD-DOME=5X6 MATRIX GENERIC SWITCH PANEL
MT >>>MOTORS
MTCRB MOTOR-COINC BELT W6PM1SMTR MESSAGE SN SEE SPECIFIC MACHINE + NAMEPLATE ON COINC
MTDF MOTOR-DOOR FAN W6PM1SMTR 13AF210071 FAN 2100 CFM 240V 60HZ ON DOOR
MTHF1 MOTOR-HOOD FAN 1 W6PM1SMTR MESSAGE SN SEE SPECIFIC MACHINE + NAMEPLATE TOP OF PRESS
MTHF2 MOTOR-HOOD FAN 2 W6PM1SMTR MESSAGE SN SEE SPECIFIC MACHINE + NAMEPLATE TOP OF PRESS
MTHP MOTOR-HYDRAULIC PUMP W6PM1SMTR MESSAGE SN SEE SPECIFIC MACHINE + NAMEPLATE TOP OF PRESS
MTPRP MOTOR-PRESS RETURN PUMP W6PM1SMTR MESSAGE SN SEE SPECIFIC MACHINE + NAMEPLATE TOP OF PRESS
MTRB MOTOR BELT W6PM1SMTR MESSAGE SN SEE SPECIFIC MACHINE + NAMEPLATE TOP OF PRESS
MTRC MOTOR-RECIRCULATION PUMP W6PM1SMTR MESSAGE SN SEE SPECIFIC MACHINE + NAMEPLATE TOP OF PRESS
PE >>>PHOTOEYES
PEGCR PHOTOEYE-GOODS AT END OF BELT W6PM1SI1 09RPE010R PHOTOEYE RECEIVER AC AT BELT
PEGCR PHOTOEYE-GOODS AT END OF BELT W6PM1SI1A 09RPE010R PHOTOEYE RECEIVER AC AT BELT
PEGCR PHOTOEYE-GOODS AT END OF BELT W6PM1SI1B 09RPE010R PHOTOEYE RECEIVER AC AT BELT
PEGCS PHOTOEYE-GOODS AT END OF BELT W6PM1SI1 09RPE010E P.E. EMITTER AC #SM303E W30' ON BELT
PEGCS PHOTOEYE-GOODS AT END OF BELT W6PM1SI1A 09RPE010E P.E. EMITTER AC #SM303E W30' ON BELT
PEGCS PHOTOEYE-GOODS AT END OF BELT W6PM1SI1B 09RPE010E P.E. EMITTER AC #SM303E W30' ON BELT
PS24 POWER SUPPLY-24VDC OUTPUT W6PM1SBW 08PSL6B224 POWER SUPPLY KEPCO#RKW 24-6.5K CONTROL BOX
PS24 POWER SUPPLY-24VDC OUTPUT W6PM1SBWA 08PSL6B224 POWER SUPPLY KEPCO#RKW 24-6.5K CONTROL BOX
PS24 POWER SUPPLY-SOFT SQUEEZE 24VDC W6PM1SSQ 08PSL6B224 POWER SUPPLY KEPCO#RKW 24-6.5K SOFT SQUEEEZE BX
PX >>>PROX SWITCHES
Page 4 of 8
4
C O M P O N E N T P A R T S L I S T W6PM1SPL/2015184N
PXCB1 PROX SW-CAN AT BOTTOM W6PM1SI1 09RPS12ADS PROXSW QD CONN 12M NO-DC SHLD SIDE OF CAN
PXCB1 PROX SW-CAN AT BOTTOM W6PM1SI1A 09RPS12ADS PROXSW QD CONN 12M NO-DC SHLD SIDE OF CAN
PXCB1 PROX SW-CAN AT BOTTOM W6PM1SI1B 09RPS12ADS PROXSW QD CONN 12M NO-DC SHLD SIDE OF CAN
PXCB2 PROX SW-CAN AT BOTTOM W6PM1SI1 09RPS12ADS PROXSW QD CONN 12M NO-DC SHLD SIDE OF CAN
PXCB2 PROX SW-CAN AT BOTTOM W6PM1SI1A 09RPS12ADS PROXSW QD CONN 12M NO-DC SHLD SIDE OF CAN
PXCB2 PROX SW-CAN AT BOTTOM W6PM1SI1B 09RPS12ADS PROXSW QD CONN 12M NO-DC SHLD SIDE OF CAN
PXCT PROX SW-CAN AT TOP W6PM1SI1 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD SIDE OF CAN
PXCT PROX SW-CAN AT TOP W6PM1SI1A 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD SIDE OF CAN
PXCT PROX SW-CAN AT TOP W6PM1SI1B 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD SIDE OF CAN
PXDDD PROX SW-DISCHARGE DOOR FULL DOWN W6PM1SI2 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD DISCHARGE DOOR
PXDDD PROX SW-DISCHARGE DOOR FULL DOWN W6PM1SI2A 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD DISCHARGE DOOR
PXDDU PROX SW-DISCHARGE DOOR FULL UP W6PM1SI2 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD DISCHARGE DOOR
PXDDU PROX SW-DISCHARGE DOOR FULL UP W6PM1SI2A 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD DISCHARGE DOOR
PXLCD PROX SW-LOAD CHUTE FULL DOWN W6PM1SI2 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD LOAD CHUTE
PXLCD PROX SW-LOAD CHUTE FULL DOWN W6PM1SI2A 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD LOAD CHUTE
PXLCU PROX SW-LOAD CHUTE FULL UP W6PM1SI2 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD LOAD CHUTE
PXLCU PROX SW-LOAD CHUTE FULL UP W6PM1SI2A 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD LOAD CHUTE
PXSB PROX SW-RAM AT BOTTOM W6PM1SI1 09RPS18ADS PRXSW QK CONN 18M NO-DC SHLD TOP OF RAM
PXSB PROX SW-RAM AT BOTTOM W6PM1SI1A 09RPS18ADS PRXSW QK CONN 18M NO-DC SHLD TOP OF RAM
PXSB PROX SW-RAM AT BOTTOM W6PM1SI1B 09RPS18ADS PRXSW QK CONN 18M NO-DC SHLD TOP OF RAM
PXSL PROX SW-RAM AT LOW W6PM1SI1A 09RPS18ADS PRXSW QK CONN 18M NO-DC SHLD TOP OF RAM
PXSL PROX SW-RAM AT LOW W6PM1SI1B 09RPS18ADS PRXSW QK CONN 18M NO-DC SHLD TOP OF RAM
PXSM PROX SW-RAM AT MIDDLE W6PM1SI1 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD TOP OF RAM
PXSM PROX SW-RAM AT MIDDLE W6PM1SI1A 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD TOP OF RAM
PXSM PROX SW-RAM AT MIDDLE W6PM1SI1B 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD TOP OF RAM
PXSS PROX SW-RAM ABOVE SLOW W6PM1SI1B 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD TOP OF RAM
PXST PROX SW-RAM AT TOP W6PM1SI1 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD TOP OF RAM
PXST PROX SW-RAM AT TOP W6PM1SI1A 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD TOP OF RAM
PXST PROX SW-RAM AT TOP W6PM1SI1B 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD TOP OF RAM
PXSU PROX SW-RAM AT UNLOAD HEIGHT W6PM1SI1 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD TOP OF RAM
PXSU PROX SW-RAM AT UNLOAD HEIGHT W6PM1SI1A 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD TOP OF RAM
PXSU PROX SW-RAM AT UNLOAD HEIGHT W6PM1SI1B 09RPS30ADS PRXSW QK CONN 30M NO-DC SHLD TOP OF RAM
SH >>>SWITCH-HAND OPERATED
SHCMD SWITCH-CONVEYOR MOTER DISCONNECT W6PM1SMTR 09N042204 DISCON SWITCH 40A 600V 2POS 4P CONV. C-BOX
SHCMD SWITCH-CONVEYOR MOTER DISCONNECT W6PM1SS+ 09N042204 DISCON SWITCH 40A 600V 2POS 4P CONV. C-BOX
Page 5 of 8
5
C O M P O N E N T P A R T S L I S T W6PM1SPL/2015184N
SHES SWITCH-EMERGENCY STOP W6PM1SS+ 09N506 SW ASSY EMER STOP VERSION 2 SWITCH PANEL
SHESR SWITCH-REMOTE EMERGENCY STOP W6PM1SS+ 09N506 SW ASSY EMER STOP VERSION 2 NON SWPNL SIDE
SHFR SWITCH-FAULT RECOVERY W6PM1SI2 09N405PB10 SWASS PBBK 1NO SWITCH PANEL
SHFR SWITCH-FAULT RECOVERY W6PM1SI2A 09N405PB10 SWASS PBBK 1NO SWITCH PANEL
SHL SWITCH SECURITY DOOR LEFT W6PM1SS+ 09RS0001 SAFETY SW.N/C SCHMERSAL#AZ15ZV PRESS DOOR LF
SHMD SWITCH-MILDATA W6PM1SI2A 09N405M210 SWASS M2W 1NO SWITCH PANEL
SHPE1 SWITCH-EMERGENCY PULL CORD W6PM1SS+ 09R014A MINI-SW SPDT STAKON #V15G1C26K DISC CONVEYOR
SHPE2 SWITCH-EMERGENCY PULL CORD W6PM1SS+ 09R014A MINI-SW SPDT STAKON #V15G1C26K DISC CONVEYOR
SHPL SWITCH-PRESS LOADED W6PM1SAI MESSAGE EW SWITCH BY OTHERS REMOTE MNTED
SHPRP SWITCH PRESS RETURN PUMP W6PM1SPP 09N405M210 SWASS M2W 1NO SWITCH PANEL
SHPRP SWITCH PRESS RETURN PUMP W6PM1SPP1 09N405M210 SWASS M2W 1NO SWITCH PANEL
SHR SWITCH-SECURITY DOOR RIGHT W6PM1SS+ 09RS0001 SAFETY SW.N/C SCHMERSAL#AZ15ZV PRESS DOOR RT
SHRFR SWITCH-REMOTE FAULT RECOVERY W6PM1SI2 09N405PB10 SWASS PBBK 1NO NON SWPNL SIDE
SHRFR SWITCH-REMOTE FAULT RECOVERY W6PM1SI2A 09N405PB10 SWASS PBBK 1NO NON SWPNL SIDE
SHS+ SWITCH-START W6PM1SS+ 09N405PB10 SWASS PBBK 1NO SWITCH PANEL
SHS+R SWITCH-REMOTE START W6PM1SS+ 09N405PB10 SWASS PBBK 1NO NON SWPNL SIDE
SHSC SWITCH-SIGNAL CANCEL W6PM1SI1 09N405PY10 SWASS PB YELLOW 1NO SWITCH PANEL
SHSC SWITCH-SIGNAL CANCEL W6PM1SI1A 09N405PY10 SWASS PB YELLOW 1NO SWITCH PANEL
SHSC SWITCH-SIGNAL CANCEL W6PM1SI1B 09N405PY10 SWASS PB YELLOW 1NO SWITCH PANEL
SHSMA SWITCH-MASTER W6PM1SS+ 09N405M220 SWASS M2W 2NO SWITCH PANEL
SHSO SWITCH-STOP W6PM1SS+ 09N404PR01 SWASS PBRD 1NC SWITCH PANEL
SK >>>SWITCH-KEYLOCK
SKI SWITCH-REMOTE DOOR BYPASS W6PM1SS+ 09N127C KEYSW SPST 7A120VAC SCREW TERM INSIDE CNT BOX
SKPRO SWITCH-RUN/PROGRAM (KEY OP) W6PM1SI1 09N127C KEYSW SPST 7A120VAC SCREW TERM SWITCH PANEL
SKPRO SWITCH-RUN/PROGRAM (KEY OP) W6PM1SI1A 09N127C KEYSW SPST 7A120VAC SCREW TERM SWITCH PANEL
SKPRO SWITCH-RUN/PROGRAM (KEY OP) W6PM1SI1B 09N127C KEYSW SPST 7A120VAC SCREW TERM SWITCH PANEL
SL >>>SWITCH-LEVEL
SLPPH SWITCH-PRESS RETURN TANK HIGH W6PM1SPP 09R014A MINI-SW SPDT STAKON #V15G1C26 PRESS RTN TNK
SLPPH SWITCH-PRESS RETURN TANK HIGH W6PM1SPP1 09R014A MINI-SW SPDT STAKON #V15G1C26 PRESS RTN TNK
SLPPL SWITCH-PRESS RETURN TANK LOW W6PM1SPP 09R014A MINI-SW SPDT STAKON #V15G1C26 PRESS RTN TNK
SLPPL SWITCH-PRESS RETURN TANK LOW W6PM1SPP1 09R014A MINI-SW SPDT STAKON #V15G1C26 PRESS RTN TNK
SM >>>SWITCH-MECHANICALLY OPERATED
SMBTL SWITCH-TAUT BELT LEFT W6PM1SI1A 09RM01209S CAPSW 9FT 180DEG ROLLER SILVER LOAD END BELT
SMBTL SWITCH-TAUT BELT LEFT W6PM1SI1B 09RM01209S CAPSW 9FT 180DEG ROLLER SILVER LOAD END BELT
SMBTR SWITCH-TAUT BELT RIGHT W6PM1SI1A 09RM01209S CAPSW 9FT 180DEG ROLLER SILVER LOAD END BELT
Page 6 of 8
6
C O M P O N E N T P A R T S L I S T W6PM1SPL/2015184N
SMBTR SWITCH-TAUT BELT RIGHT W6PM1SI1B 09RM01209S CAPSW 9FT 180DEG ROLLER SILVER LOAD END BELT
VE >>>VALVE-ELECTRIC OPERATED
VE100 VALVE-LOWEST RAM PRESSURE W6PM1SSQ 96RH712A02 SUN CART&COIL#DAAAMHN211 AT BOOSTER PUMP
VE250 VALVE-SECOND LOWEST RAM PRESSURE W6PM1SSQ 96RH712A02 SUN CART&COIL#DAAAMHN211 AT BOOSTER PUMP
VEBP VALVE-BYPASS W6PM1SVS 96RH708E37 PRESSURE RELIEF VALVE-REXROTH HYDRAULIC UNIT
VEBP VALVE-BYPASS W6PM1SVSA 96RH712A02 DIRECTIONAL VALVE PREFIL PILOT HYDRAULIC UNIT
VEBP VALVE-BYPASS W6PM1SVSB 96RH712A02 DIRECTIONAL VALVE PREFIL PILOT HYDRAULIC UNIT
VECD VALVE-LOAD CHUTE DOWN W6PM1SVS 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VECD VALVE-LOAD CHUTE DOWN W6PM1SVS 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VECD VALVE-LOAD CHUTE DOWN W6PM1SVSA 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VECL VALVE-CAN TO LOWER W6PM1SVS 96RH712A01 DIRECTIONAL VALVE HYDRAULIC UNIT
VECL VALVE-CAN TO LOWER W6PM1SVSA 96RH709E37 DIRECT.VALVE CENTER OP 24VDC HYDRAULIC UNIT
VECL VALVE-CAN TO LOWER W6PM1SVSB 96RH709E37 DIRECT.VALVE CENTER OP 24VDC HYDRAULIC UNIT
VECR VALVE-CAN TO RAISE W6PM1SVS 96RH712A01 DIRECTIONAL VALVE HYDRAULIC UNIT
VECR VALVE-CAN TO RAISE W6PM1SVSA 96RH709E37 DIRECT.VALVE CENTER OP 24VDC HYDRAULIC UNIT
VECR VALVE-CAN TO RAISE W6PM1SVSB 96RH709E37 DIRECT.VALVE CENTER OP 24VDC HYDRAULIC UNIT
VECU VALVE-LOAD CHUTE UP W6PM1SVS 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VECU VALVE-LOAD CHUTE UP W6PM1SVSA 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VEDDD VALVE-DISCHARGE DOOR DOWN W6PM1SVS 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VEDDD VALVE-DISCHARGE DOOR DOWN W6PM1SVSA 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VEDDD VALVE-DISCHARGE DOOR DOWN W6PM1SVSB 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VEDDU VALVE-DISCHARGE DOOR UP W6PM1SVS 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VEDDU VALVE-DISCHARGE DOOR UP W6PM1SVSA 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VEDDU VALVE-DISCHARGE DOOR UP W6PM1SVSB 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VEDFD VALVE-DISCHARGE FLAG DOWN W6PM1SVS 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VELFD VALVE-LOAD FLAG DOWN W6PM1SVS 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VELFD VALVE-LOAD FLAG DOWN W6PM1SVSA 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VELFD VALVE-LOAD FLAG DOWN W6PM1SVSB 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VEPP1 VALVE-POPPET #1 W6PM1SVS 96RH710E37 POPPET VALVE-SOLENOID=HYDRA HYDRAULIC UNIT
VEPP1 VALVE-POPPET #1 W6PM1SVSA 96DH452A01 POPPET=COIL + CARTRIDGE HYDRAULIC UNIT
VEPP1 VALVE-POPPET #1 W6PM1SVSB 96DH452A01 POPPET=COIL + CARTRIDGE HYDRAULIC UNIT
VEPP2 VALVE-POPPET #2 W6PM1SVS 96RH710E37 POPPET VALVE-SOLENOID=HYDRA HYDRAULIC UNIT
VEPP2 VALVE-POPPET #2 W6PM1SVSA 96DH452A01 POPPET=COIL + CARTRIDGE HYDRAULIC UNIT
VEPP2 VALVE-POPPET #2 W6PM1SVSB 96DH452A01 POPPET=COIL + CARTRIDGE HYDRAULIC UNIT
VEPRP VALVE-RETURN SEAL WATER W6PM1SSP 96TCC2AA37 3/8" N/C 2WAY 120V50/60C ON REUSE TANK
Page 7 of 8
7
C O M P O N E N T P A R T S L I S T W6PM1SPL/2015184N
VERDB VALVE-RAM DOWN BYPASS W6PM1SVS 96RH713A02 SUN CART&COIL#DAAAMHN211 HYDRAULIC UNIT
VERDB VALVE-RAM DOWN BYPASS W6PM1SVSA 96RH713A02 SUN CART&COIL#DAAAMHN211 HYDRAULIC UNIT
VERDB VALVE-RAM DOW BYPASS W6PM1SVSB 96RH713A02 SUN CART&COIL#DAAAMHN211 HYDRAULIC UNIT
VERL VALVE-RAM TO LOWER W6PM1SVS 96RH709E37 PROP. DIRECT.CONTROL VALVE HYDRAULIC UNIT
VERL VALVE-RAM TO LOWER W6PM1SVSA 96RH709E37 PROP. DIRECT.CONTROL VALVE HYDRAULIC UNIT
VERL VALVE-RAM TO LOWER W6PM1SVSB 96RH709E37 DIRECT.VALVE CENTER OP 24VDC HYDRAULIC UNIT
VERR VALVE-RAM TO RAISE W6PM1SVS 96RH709E37 PROP. DIRECT.CONTROL VALVE HYDRAULIC UNIT
VERR VALVE-RAM TO RAISE W6PM1SVSA 96RH709E37 PROP. DIRECT.CONTROL VALVE HYDRAULIC UNIT
VERR VALVE-RAM TO RAISE W6PM1SVSB 96RH709E37 DIRECT.VALVE CENTER OP 24VDC HYDRAULIC UNIT
VERS VALVE-PREFILL W6PM1SVS 09RH712E37 PREFILL VALVE HYDRAULIC UNIT
VERS VALVE-PREFILL W6PM1SVSA 09RH712E37 PREFILL VALVE HYDRAULIC UNIT
VERS VALVE-PREFILL W6PM1SVSB 96RH712E37 PREFILL VALVE REXROTH-ZSFW100 HYDRAULIC UNIT
VESR VALVE-SPRAY RING W6PM1SVSA 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VESR VALVE-SPRAY RING W6PM1SVSB 96R301B37 1/8" AIRPILOT 3W NC 120V50/60 AIR VALVE BOX
VEW VALVE-WATER COOL DOWN W6PM1SS+ 96TDC2AA37 1/2"N/C2WY120V50/60C VLV(DRYVC TOP OF PRESS
VR >>>VERISTOR
VRC VERISTOR-CAN UP/DOWN W6PM1SVS 09ARC055J VARS .0055 MFD 30VDC HYD JUNCTION BOX
VRC VERISTOR-CAN UP/DOWN W6PM1SVSA 09ARC055J VARS .0055 MFD 30VDC HYD JUNCTION BOX
VRC VERISTOR-CAN UP/DOWN W6PM1SVSB 09ARC055J VARS .0055 MFD 30VDC HYD JUNCTION BOX
VRR VERISTOR-RAM UP/DOWN W6PM1SVS 09ARC055J VARS .0055 MFD 30VDC HYD JUNCTION BOX
VRR VERISTOR-RAM UP/DOWN W6PM1SVSA 09ARC055J VARS .0055 MFD 30VDC HYD JUNCTION BOX
VRR VERISTOR-RAM UP/DOWN W6PM1SVSB 09ARC055J VARS .0055 MFD 30VDC HYD JUNCTION BOX
Page 8 of 8
8
PELLERIN MILNOR CORPORATION
LIMITED STANDARD WARRANTY
We warrant to the original purchaser that MILNOR machines including electronic
hardware/software (hereafter referred to as “equipment”), will be free from defects in material and
workmanship for a period of one year from the date of shipment (unless the time period is specifically
extended for certain parts pursuant to a specific MILNOR published extended warranty) from our
factory with no operating hour limitation. This warranty is contingent upon the equipment being
installed, operated and serviced as specified in the operating manual supplied with the equipment,
and operated under normal conditions by competent operators.
Providing we receive written notification of a warranted defect within 30 days of its discovery, we
will at our option repair or replace the defective part or parts, FOB our factory. We retain the right to
require inspection of the parts claimed defective in our factory prior to repairing or replacing same.
We will not be responsible, or in any way liable, for unauthorized repairs or service to our equipment,
and this warranty shall be void if the equipment is tampered with, modified, or abused, used for
purposes not intended in the design and construction of the machine, or is repaired or altered in any
way without MILNOR's written consent.
Parts damaged by exposure to weather, to aggressive water, or to chemical attack are not covered by
this warranty. For parts which require routine replacement due to normal wear such as gaskets,
contact points, brake and clutch linings, belts, hoses, and similar parts the warranty time period is 90
days.
We reserve the right to make changes in the design and/or construction of our equipment (including
purchased components) without obligation to change any equipment previously supplied.
ANY SALE OR FURNISHING OF ANY EQUIPMENT BY MILNOR IS MADE ONLY UPON
THE EXPRESS UNDERSTANDING THAT MILNOR MAKES NO EXPRESSED OR IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR USE OR
PURPOSE
. MILNOR WILL NOT BE RESPONSIBLE FOR ANY COSTS OR
DAMAGES ACTUALLY INCURRED OR REQUIRED AS A RESULT OF: THE FAILURE OF
ANY OTHER PERSON OR ENTITY TO PERFORM ITS RESPONSIBILITIES, FIRE OR
OTHER HAZARD, ACCIDENT, IMPROPER STORAGE, MIS-USE, NEGLECT, POWER OR
ENVIRONMENTAL CONTROL MALFUNCTIONS, DAMAGE FROM LIQUIDS, OR ANY
OTHER CAUSE BEYOND THE NORMAL RANGE OF USE. REGARDLESS OF HOW
CAUSED, IN NO EVENT SHALL MILNOR BE LIABLE FOR SPECIAL, INDIRECT,
PUNITIVE, LIQUIDATED, OR CONSEQUENTIAL COSTS OR DAMAGES, OR ANY COSTS
OR DAMAGES WHATSOEVER WHICH EXCEED THE PRICE PAID TO MILNOR FOR THE
EQUIPMENT IT SELLS OR FURNISHES.
THE PROVISIONS ON THIS PAGE REPRESENT THE ONLY WARRANTY FROM MILNOR
AND NO OTHER WARRANTY OR CONDITIONS, STATUTORY OR OTHERWISE, SHALL
BE IMPLIED.
WE NEITHER ASSUME, NOR AUTHORIZE ANY EMPLOYEE OR OTHER PERSON TO
ASSUME FOR US, ANY OTHER RESPONSIBILITY AND/OR LIABILITY IN CONNECTION
WITH THE SALE OR FURNISHING OF OUR EQUIPMENTTOANYBUYER.
OR ANY OTHER WARRANTY IMPLIED BY LAW INCLUDING BUT NOT
LIMITED TO REDHIBITION
BMP720097/2008272A
9
How to Get the Necessary Repair Components
PELLERIN MILNOR CORPORATION
BIUUUD19 (Published) Book specs- Dates: 20081231 / 20081231 / 20081231 Lang: ENG01 Applic: UUU
How to Get the Necessary Repair Components
This document uses Simplified Technical English.
Learn more at http://www.asd-ste100.org.
You can get components to repair your machine from the approved supplier where you got this
machine. Your supplier will usually have the necessary components in stock. You can also get
components from the Milnor®factory.
Tell the supplier the machine model and serial number and this data for each necessary component:
• The component number from this manual
• The component name if known
• The necessary quantity
• The necessary transportation requirements
• If the component is an electrical component, give the schematic number if known.
• If the component is a motor or an electrical control, give the nameplate data from the used
component.
To write to the Milnor factory:
Pellerin Milnor Corporation
Post Office Box 400
Kenner, LA 70063-0400
UNITED STATES
Telephone: 504-467-2787
Fax: 504-469-9777
Email: [email protected]
— End of BIUUUD19 —
10
PELLERIN MILNOR CORPORATION
BICALC02 (Published) Book specs- Dates: 20031016 / 20031016 / 20031017 Lang: ENG01 Applic: CP1
Milnor®Allied Interface Specifications and Signals, Single Stage
Press
An allied device that interfaces with the Milnor system machine equipped with Mark 5 or later
microprocessor controls must meet the electrical specifications and functional requirements given
in Section 1 “Electrical and Functional Specifications”.
The “Signals...” section(s) herein identify the allied interface signals and provide related
information (see Section 2 “How the Signals Tables Are Organized”).
This document also provides useful information for troubleshooting allied interfaces:
• The Display/code and Board/code values in the signals tables, are cross-references to the
output and input displays and to the output and input numbers on the I/O boards respectively.
Section 4 “Monitoring Allied Interface Outputs and Inputs”, explains how to use these cross-
references.
• As an aid in working with numeric signals, Section 5 “Decimal / Binary Conversion and
How It Applies to Allied Interfaces” explains how to determine, for any batch code, which
value (off or on) each signal in a group should pass.
1. Electrical and Functional Specifications
WARNING 1 : Electrocution and Electrical Burn Hazards—Contact with high voltage
will electrocute or burn you. Power switches on the machine and the control box do not eliminate
these hazards. High voltage is present at the machine unless the main machine power disconnect
is off.
• Do not service machine unless qualified and authorized.
• Lock out and tag out power at the main machine disconnect before opening electric boxes
and accessing electrical components.
For inputs from Milnor (Milnor outputs), the allied device must limit circuit load to that specified
in Section 1.1, below. For outputs to Milnor (Milnor inputs), the allied device must supply
circuitry that meets the specifications in Section 1.2, below. The functional requirements stated in
Section 1.3 must be met for proper coordination and data exchange between the devices.
1.1. Permissible Load for Milnor Outputs—For signals from Milnor to allied (Milnor
outputs/allied inputs), Milnor supplies potential-free contacts located on board-mounted relays.
The signals are conducted by traces on the board having the following capacity:
• Maximum voltage: 240V
• Maximum current: 0.5 amps
• Maximum VA: 3
CAUTION 2 : Risk of Damage/Malfunction—Traces on control boards may burn out,
requiring board replacement, if called upon to handle heavy currents. High voltages can cause
arcing across traces.
• Do not apply loads exceeding the specified capacity.
• Do not use allied interface outputs to operate motors or for any other unintended purpose.
These may, however, be used to operate relays that do not exceed the specified capacity.
11
Milnor®Allied Interface Specifications and Signals, Single Stage Press
PELLERIN MILNOR CORPORATION
1.2. Component Requirements for Milnor Inputs—For signals from allied to Milnor
(allied outputs/Milnor inputs–which connect directly to control boards and are used to ground
Milnor control inputs), Milnor applies a low energy signal as follows:
• Voltage: 5VDC or 12VDC
• Minimum current: 5 milliamps
The potential-free contacts supplied by allied and the circuit wiring must be capable of faithfully
carrying these low energy signals.
CAUTION 3 : Risk of Bad Data—Resistance due to wire length or deteriorated contacts can
mask signals. Inadequate shielding against electrical noise can trigger false signals.
• Keep wire runs as short as possible.
• Use a digital signal ground connection (wire number 2G on the CBW; wire number 7 on
other Milnor devices), not merely chassis ground.
• Ground any spare wires.
• Pass all wires through a ferrite bead.
• Replace relays that have worn or corroded contacts.
• Do not run input wiring adjacent to, or in the same conduit with, any wires carrying AC.
For example, do not run input and output wiring in the same conduit if AC is used to
power Milnor output/allied input signals.
1.3. Functional Requirements
1. For numeric signals (batch codes) from allied to Milnor (allied loading interface), all signals
must be properly set when the operational signal indicating this data is valid occurs. Signals
must remain set for the longer of 5 seconds or through any subsequent operational signal
requiring this data (see “Loading Interface non-Numeric Signals...”). Milnor will read all
numeric signals during this time.
2. For numeric signals from Milnor to allied (allied discharge interface), allied must not read
signals until the data valid, or other operational signal indicating data is valid occurs (see
“Discharge Interface non-Numeric Signals...”).
3. Although not all the operational signals listed in the tables are necessarily required, (the
signals used will vary with specific machine models and with variations in the operating
cycle), those signals used, must occur in the order listed.
4. When connecting numeric signals between devices, ensure that signals are properly matched
up with respect to significance (least significant-to-least significant, next least significant-to-
next least significant, etc.).
2. How the Signals Tables Are Organized
For an allied device that loads the Milnor machine, Milnor provides an allied loading interface.
For an allied device that receives goods from (discharges) the Milnor machine, Milnor provides
an allied discharge interface. In both cases, some signals are used in groups to pass numeric
values in binary and some signals are used individually to pass non-numeric (on/off) values. The
receiving device can read the groups of numeric signals in any order as long as it reads this data
during the window of time within which it is valid. However, because each signal within a group
of numeric signals represents a specific digit of the binary number, the order of significance of
the signals (digit order) must be understood and must match on sending and receiving devices.
Most non-numeric signals provide operational information which must be exchanged according
to a predetermined “handshaking” scheme. Hence, the sequence in which operational signals
occur (enabling order) is critical. Accordingly, the signal information is presented in four tables:
12
PELLERIN MILNOR CORPORATION
1. Loading interface numeric input signals and digit order—In this table, signals are
depicted in digit order, that is, the way they would be read as a binary number. The rightmost
column represents the signal that carries the least significant digit. Each adjacent column to
the left is the signal representing the digit of next higher significance. The table is divided
into row groups—one row group for each batch code provided. Each row group provides
pertinent information for the signals used with that batch code. In an allied loading interface,
all numeric signals pass from allied to Milnor and are therefore, inputs to Milnor.
2. Loading interface non-numeric signals and enabling order—In this table, each row
represents a signal and each column provides pertinent information for that signal. Generally,
these signals must be exchanged by the interfaced devices in the order listed. The labels given
to operational signals in the schematics can vary from device to device. However, the
document “Summary of Milnor Allied Interface Capability” provides generic names for
these. The right-hand column of this table provides both the generic (function) name and the
signal name as shown in the schematic, except where these are the same.
3. Discharge interface numeric output signals and digit order—This table is arranged the
same as the “loading interface numeric...” table. However, in an allied discharge interface, all
numeric signals pass from Milnor to allied and are therefore, outputs from Milnor.
4. Discharge interface non-numeric signals and enabling order—This table is arranged the
same as the “loading interface non-numeric...” table. As with a loading interface, the devices
need to exchange these signals in the order shown.
13
Milnor®Allied Interface Specifications and Signals, Single Stage Press
PELLERIN MILNOR CORPORATION
3. Signals—Single Stage Press With Mark 5 Controls[Document
BICALC14]
Table 1: Loading Interface Numeric Input Signals and Digit Order—Single Stage Press
Common
Conn.
Most
Significant Dedicated Connections (Binary Data Signals) Least
Significant
Signal name on schematic
(e.g., Drycode A, B, etc.)--> K J H G F E D C B A
Multi-terminal TBA WC2 WC2 WC2 WC2
Pin Number 7 7 16 18 17
Wire Number 7232 244 243 242
Display/code -- i2/C i1/p i1/o i1/n
16 Drycodes
(00 - 15)
Board/code -- io2/6 io1/15 io1/14 io1/13
Multi-terminal TBA WCI WCI WCI WCI
Pin Number 716 15 8 7
Wire Number 7341 342 331 332
Display/code -- Not available
16 Destina-
tion Codes
(00-15)
Board/code -- io3/15 io3/14 io3/7 io3/6
Multi-terminal TBA WCI WCI WCI WCI WCI WCI WCI WCI
Pin Number 718 17 14 13 12 11 10 9
Wire Number 7396 391 343 344 347 348 349 340
Display/code -- i2/G i2/F Not available
256 Custo-
mer Codes
(000-255)
Board/code -- * * io3/13 io3/12 io3/11 io3/10 io3/9 io3/8
Multi-terminal TBA WCI WCI WCI WCI WCI WCI
Pin Number 7 6 5 4 3 2 1
Wire Number 7333 334 337 338 339 330
Display/code -- Not available i2/T i2/S i2/R
64 Goods
Codes (00-
63)
Board/code -- io3/5 io3/4 io3/3 io3/2 io3/1 io3/0
Multi-terminal TBA WC2 WC2 WC2 WC2
Pin Number 7 4 3 2 1
Wire Number 7237 238 239 230
Display/code -- i1/t i1/s i1/r i1/q
16 Extract
(Press)
Codes (00-
15)
Board/code -- io2/3 io2/2 io2/1 io2/0
* Customer codes G and H use direct inputs on the processor board, not inputs on the peripheral boards.
Table 2: Loading Interface non-Numeric Signals and Enabling Order—Single Stage Press
Common Connection* Dedicated Connection
Signal
Direc-
tion
Multi-
terminal Pin Wire Multi-
terminal Pin Wire
Display
/ code
Board /
code Function Name / Signal Name
Output* WCY 17 312* WCY 16 132 o1/j o1/1 load allowed / press free
Milnor will read in all batch data (previous table and next three signals) when it receives the "transfer complete / press loaded"
signal.
Input WCY 22 7WCY 10 411 i1/i io1/8 new customer
Input WCY 25 7WCY 13 414 i1/l io1/11 single cake
Input WCY 26 7WCY 14 415 i1/m io1/12 empty load
Input WCY 21 7WCY 20 386 i2/P ** transfer complete / press loaded
* For outputs from Milnor, Milnor does not normally assign either pin of the potential-free contact as the common. Hence, both pins
have unique pin and wire numbers.
** This signal uses a direct input on the processor board, not an input on a peripheral board.
14
PELLERIN MILNOR CORPORATION
Table 3: Discharge Interface Numeric Output Signals and Digit Order—Single Stage Press
Common
Conn.*
Most
Significant Dedicated Connections (Binary Data Signals) Least
Significant
Signal name on schematic
(e.g., Drycode A, B, etc.)--> K J H G F E D C B A
Multi-terminal n/a WCZ WCZ WCZ WCZ
Pin Number n/a 15 • 16 13 • 14 11 • 12 9 • 10
Wire Number n/a 268 •
269
266 •
267
264 •
265
261 •
262
Display/code -- o2/T o2/S o2/R o2/Q
16 Drycodes
(00 - 15)
Board/code -- io2/7 io2/6 io2/5 io2/4
Multi-terminal n/a WCZ WCZ WCZ WCZ
Pin Number n/a 7 • 8 5 • 6 3 • 4 1 • 2
Wire Number n/a 252 •
260
254 •
253
256 •
255
259 •
258
Display/code -- o2/P o2/O o2/N o2/M
16 Destina-
tion Codes
(00-15)
Board/code -- io2/3 io2/2 io2/1 io2/0
Multi-terminal n/a WCY WCY WCY WCY WCY WCY WCY WCY
Pin Number n/a 1 • 9** 1 • 8** 1 • 7** 1 • 6** 1 • 5** 1 • 4** 1 • 3** 1 • 2**
Wire Number n/a 134 •
321
134 •
320
134 •
319
134 •
318
134 •
317
134 •
316
134 •
315
134 •
314
Display/code -- o2/L o2/K o2/J o2/I o2/H o2/G o2/F o2/E
256
Customer
Codes (000-
255)
Board/code -- o1/23 o1/22 o1/21 o1/20 o1/19 o1/18 o1/17 o1/16
Multi-terminal n/a WCX WCX WCX WCX WCX WCX WCX WCX
Pin Number n/a 15 • 16 13 • 14 11 • 12 9 • 10 7 • 8 5 • 6 3 • 4 1 • 2
Wire Number n/a 368 •
369
366 •
367
364 •
365
361 •
362
352 •
360
354 •
353
356 •
355
359 •
358
Display/code -- Not available
256 Goods
Codes (000-
255)
Board/code -- io3/7 io3/6 io3/5 io3/4 io3/3 io3/2 io3/1 io3/0
* For outputs from Milnor, Milnor does not normally assign either pin of the potential-free contact as the common. Hence, both pins
have unique pin and wire numbers. In this table these are listed together in the same cell, with a dot between (e.g., C • D)
**To provide eight customer code signals with limited available terminals, Customer codes A through H had to share pin 1.
Table 4: Discharge Interface non-Numeric Signals and Enabling Order—Single Stage Press
Common Connection* Dedicated Connection
Signal
Direc-
tion
Multi-
terminal Pin Wire Multi-
terminal Pin Wire
Display
/ code
Board /
code Function Name / Signal Name
Milnor will set all batch data (previous table) before it enables the "discharge desired / desires to unload" signal.
Output* WCY 19 313* WCY 18 133 o1/k o1/2 discharge desired / desires to unload
Input WCY 23 7WCY 11 412 i1/j io1/9 load allowed / start discharge
* For outputs from Milnor, Milnor does not normally assign either pin of the potential-free contact as the common. Hence, both pins
have unique pin and wire numbers.
4. Monitoring Allied Interface Outputs and Inputs
The status of outputs and inputs can be monitored on the machine display while the machine is in
operation, as explained in the machine reference manual (see Note 1 and Note 2). Beginning with
Mark 4 controls (Mark 9 on the CBW), output and input status can also be monitored on the I/O
boards. These boards contain LED's—one green LED for each input and one red LED for each
output (see Note 3). When the LED is illuminated, the circuit is made.
15
Milnor®Allied Interface Specifications and Signals, Single Stage Press
PELLERIN MILNOR CORPORATION
Note 1: It is also possible to actuate certain outputs for testing, as explained in the reference manual.
However, the “Display/code” values in the tables herein, refer only to the displays used to view
outputs/inputs.
Note 2: The outputs and inputs available for viewing on the display include some (but not all) allied
interface signals as well as signals for many other functions. See the reference manual for a listing of all
outputs and inputs that can be monitored during operation.
Note 3: Almost all allied interface outputs and inputs are passed via the I/O boards (peripheral boards) and
are therefore, represented by LED's on the boards. A few, however, are passed directly via the processor
board (direct outputs/inputs). The processor board does not contain LED's.
4.1. Identifying Outputs and Inputs on the Display Pages —On CBW's, some allied
inputs are available for viewing on the Mentor Direct and Standard Inputs page (as indicated in
the signals tables). It is fairly easy to identify signals on the Mentor because the signal names are
displayed.
The single stage press, two stage press, centrifugal extractor, shuttle, COBUC, and dryer use a
two or four line by 20 character LCD display (see Note 4). On these devices, each output or input
is represented by a character (lower or upper case letter) on the top line and a plus (+) or minus (-)
sign under the character indicating the on/off status of the signal. The outputs and inputs span
several display pages. Each page is accessed via the keypad and the procedures for doing so are
explained in the reference manual. The “Display/code” values listed in the tables herein tell you
which display page and character represent the indicated signal, as shown in the following
example:
i2/H
Where:
i = input display page (o = output display page)
2 = the second in a series of input display pages. See the
reference manual for the keystrokes used to access each
display page in the series. Note that in some software such as
the centrifugal extractor, page numbering begins with 0
(zero); that is, the first page is page #0. Hence, on software
such as the extractor, i2 = inputs page #1 (the second inputs
page).
H = This input is represented by the character “H” on the
display.
Note 4: When the Milnor Dryer/Shuttle Controller is provided for a new installation, the LCD displays are
omitted from the controllers for any shuttle(s) and dryer(s) also provided. In this case, inputs and outputs
may be viewed on the monitor supplied with the shuttle/dryer controller. As with the CBW Mentor
controller, it is easy to identify signals because the signal names are displayed.
4.2. Identifying Output and Input LED's On the I/O Boards (all except 76032
CBW)—Two types of output/input peripheral boards are used in conjunction with the allied
interfaces covered herein. Their designations and capacities are:
1. BO24-x—contains 24 outputs (and no inputs). x is “1”, “2”, etc. indicating the first, second,
etc. such board in this machine.
2. BIO-x—contains 16 inputs and 8 outputs. x is “1”, “2”, etc. indicating the first, second, etc.
such board in this machine.
For all except the CBW, the peripheral boards are located in the low voltage electric box. The
arrangement and combination of these boards within the card cage varies with the machine type
and optional equipment provided. For the G3 CBW (Mark 9), the boards that support the explicit
16

This manual suits for next models

8

Other Milnor Industrial Equipment manuals

Milnor MWF125J7 User manual

Milnor

Milnor MWF125J7 User manual

Milnor DRYVAC03 Manual

Milnor

Milnor DRYVAC03 Manual

Milnor DRYVAC02 Manual

Milnor

Milnor DRYVAC02 Manual

Milnor CF4010 Series User manual

Milnor

Milnor CF4010 Series User manual

Milnor 6450TG1L/R User manual

Milnor

Milnor 6450TG1L/R User manual

Milnor 76028 CBW User manual

Milnor

Milnor 76028 CBW User manual

Milnor PulseFlow 76028 G3 Manual

Milnor

Milnor PulseFlow 76028 G3 Manual

Milnor 36026X8R Operating manual

Milnor

Milnor 36026X8R Operating manual

Milnor COSHN111 Manual

Milnor

Milnor COSHN111 Manual

Milnor 72046M5K User manual

Milnor

Milnor 72046M5K User manual

Milnor 5050 User manual

Milnor

Milnor 5050 User manual

Milnor 48040F7B User manual

Milnor

Milnor 48040F7B User manual

Milnor 48040M7K User manual

Milnor

Milnor 48040M7K User manual

Milnor MT140S1L User manual

Milnor

Milnor MT140S1L User manual

Milnor TS1L/R User manual

Milnor

Milnor TS1L/R User manual

Milnor 6450TG1L User manual

Milnor

Milnor 6450TG1L User manual

Milnor 5050 TS1L User manual

Milnor

Milnor 5050 TS1L User manual

Milnor COSHR111 Manual

Milnor

Milnor COSHR111 Manual

Milnor 6458TG1L User manual

Milnor

Milnor 6458TG1L User manual

Milnor CBW Operating manual

Milnor

Milnor CBW Operating manual

Milnor M60SGH01AE User manual

Milnor

Milnor M60SGH01AE User manual

Milnor 7676TG1L/R User manual

Milnor

Milnor 7676TG1L/R User manual

Milnor MILRAIL User manual

Milnor

Milnor MILRAIL User manual

Milnor 48040M7K User manual

Milnor

Milnor 48040M7K User manual

Popular Industrial Equipment manuals by other brands

ABB RELION 650 SERIES Communication protocol manual

ABB

ABB RELION 650 SERIES Communication protocol manual

ITI 135310 Operation manual

ITI

ITI 135310 Operation manual

Tyco Rovalve S20 Installation and maintenance instructions

Tyco

Tyco Rovalve S20 Installation and maintenance instructions

Panblast PB1500P Product Operating Manual

Panblast

Panblast PB1500P Product Operating Manual

Siemens SINUMERIK 808D installation manual

Siemens

Siemens SINUMERIK 808D installation manual

TigerStop TigerGauge installation guide

TigerStop

TigerStop TigerGauge installation guide

Bend-Tech Dragon A400 Start-Up and Training Manual

Bend-Tech

Bend-Tech Dragon A400 Start-Up and Training Manual

PCB Piezotronics M1630-03C Installation and operating manual

PCB Piezotronics

PCB Piezotronics M1630-03C Installation and operating manual

Carl Stahl Kromer 7230 Series operating instructions

Carl Stahl Kromer

Carl Stahl Kromer 7230 Series operating instructions

hager GTV FLF Series Mounting instructions

hager

hager GTV FLF Series Mounting instructions

Wilo Stratos PICO Installation and operating instructions

Wilo

Wilo Stratos PICO Installation and operating instructions

Aerotech PRO115LM Hardware manual

Aerotech

Aerotech PRO115LM Hardware manual

Eller ELPTS operating instructions

Eller

Eller ELPTS operating instructions

ABB LT 460AC operating instructions

ABB

ABB LT 460AC operating instructions

ABB HT576107 Operation manual

ABB

ABB HT576107 Operation manual

Branick 500 Installation, Operation & Repair Parts Information

Branick

Branick 500 Installation, Operation & Repair Parts Information

Sam QUICK HITCH Instructions and parts manual

Sam

Sam QUICK HITCH Instructions and parts manual

ABB HT846855 Operation manual

ABB

ABB HT846855 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.