manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Milwaukee
  6. •
  7. Controllers
  8. •
  9. Milwaukee MC510 User manual

Milwaukee MC510 User manual

Other Milwaukee Controllers manuals

Milwaukee MC110 User manual

Milwaukee

Milwaukee MC110 User manual

Milwaukee 0950-20 User manual

Milwaukee

Milwaukee 0950-20 User manual

Milwaukee BLACK BOX DL510 Manual instruction

Milwaukee

Milwaukee BLACK BOX DL510 Manual instruction

Milwaukee MC740 User manual

Milwaukee

Milwaukee MC740 User manual

Milwaukee MC720 User manual

Milwaukee

Milwaukee MC720 User manual

Milwaukee DL122 Manual instruction

Milwaukee

Milwaukee DL122 Manual instruction

Milwaukee MC311 User manual

Milwaukee

Milwaukee MC311 User manual

Milwaukee M12 551B-21 User manual

Milwaukee

Milwaukee M12 551B-21 User manual

Milwaukee MC720 User manual

Milwaukee

Milwaukee MC720 User manual

Milwaukee MC745 User manual

Milwaukee

Milwaukee MC745 User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

USER MANUAL
MC510
PRO Digital ORP Controller
milwaukeeinstruments.com (USA & CAN)
milwaukeeinst.com
OPTIONAL ACCESSORIES
MA921B/2 ORP Electrode with BNC connector and
2m cable
M10000B Electrode rinse solution, 20 mL sachet
(25 pcs)
MA9015 Electrode storage solution, 220 mL
bottle
CERTIFICATION
Milwaukee Instruments conform to the CE European
Directives.
RoHS
COMPLIANT
Disposal of Electrical & Electronic Equipment. Do not
treat this product as household waste. Hand it over to the
appropriate collection point for the recycling of electrical
and electronic equipment.
Please note: proper product prevents potential
negative consequences for human health and the
environment. For detailed information, contact your
local household waste disposal service or go to
www.milwaukeeinstruments.com (USA & CAN) or
www.milwaukeeinst.com.
RECOMMENDATION
Before using this product, make sure it is entirely
suitable for your specific application and for the
environment in which it is used. Any modification
introduced by the user to the supplied equipment
may compromise the meter’s performance. For your
and the meter’s safety do not use or store the meter in
hazardous environment. To avoid damage or burn, do
not perform any measurement in microwave ovens.
WARRANTY
This instrument is warranted against defects in
materials and manufacturing for a period of 2years
from the date of purchase. Probe is warranted for
6 months. This warranty is limited to repair or free
of charge replacement if the instrument cannot be
repaired. Damage due to accidents, misuse, tampering
or lack of prescribed maintenance is not covered by
warranty. If service is required, contact your local
Milwaukee Instruments Technical Service. If the repair
is not covered by the warranty, you will be notified of
the charges incurred. When shipping any meter, make
sure it is properly packaged for complete protection.
We reserve the right to modify the design,
construction and appearance of our products
without advance notice.
ISTMC510_07_20
SATISFACTION
GUARANTEED
OPERATION
yConnect the supplied 12 VDC power adapter to the
meter and to the mains line.
yConnect the ORP electrode to the BNC socket on the
bottom of the meter.
yAlways remove the electrode protective cap before
taking any measurement. If the electrode has been
left dry, soak the tip (bottom 2.5 cm) in rinse solution
(M10000B) for a few minutes to reactivate it.
yTurn the instrument on by pressing the ON/OFF key.
yAllow the reading to stabilize and the meter will
start continuous monitoring.
yThe meter is factory calibrated.
yA blinking alarm will indicate when the measured
ORP value is lower or higher than the setpoint,
depending on user selection..
Note: The power contact is not protected by fuse
inside the meter. It is recommended to protect it
outside, against failure.
WARNING: when the alarm led is blinking, the mains
voltage is present in the output power socket.
SETPOINT
yThe setpoint can be selected by adjusting the
central front knob to the desired value.
yThe selectable range for MC510 is from 0 to 600 mV.
yThe nature of the setpoint can be selected by
setting the switch to the desired position (ABOVE
or BELOW).
INSTALLATION PROCEDURE
SPECIFICATIONS
Range ±1000 mV
Resolution 1 mV
Accuracy
(@25°C) ±5 mV
Setpoint 0 to 600 mV
Alarm
active when the measure is
lower/higher than setpoint
depending on user selection
Output Power
Socket
active when the measure is
higher/lower than selected
setpoint
(5A max) depending on user
selection
ORP Electrode MA921B/2 (included)
Environment 0 to 50°C, 95% RH max.
Power Supply 12 VDC (included)
Power Drivers 115VAC, 2A, 60Hz or
230VAC, 1A, 50Hz
Dimensions 148.5 x 82.5 x 32 mm
Weight 180 g (meter only)