  9. Milwaukee MC720 User manual

Milwaukee MC720 User manual

USER MANUAL
MC720
MILWAUKEE MC122 PH CONTROLLER
WITH MP810 1,5 L/H DOSING PUMP
Smart Monitoring System
SPECIFICATIONS
MC122 pH Meter
Range 0.0 to 14.0 pH
Resolution 0.1 pH
Accuracy ±0.2 pH (@25°C)
Setpoint 5.5 to 9.5 pH
Alarm / Output active when measure is
Power Socket higher/lower than selected
setpoint depending on
user selection
Power drivers 115VAC, 2A, 60Hz
or 230VAC, 1A, 50Hz
pH electrode MA911B/2 (included)
Environment 0 to 50°C, 95% RH
not condensing
Power supply 12 VDC (included)
Dimensions 148.5 x 82.5 x 32 mm
Weight 180 g
It is suggested to dissolve 10 cL of pH reducing acid in a 5L container of mineral water.
Depending on the volume of your tank and the brand of you pH reducing acid (if it is
more or less concentrated), this quantity will be balanced. It is better to dissolve more
than less. It is suggested to use an airstone on the bottom of your tank. The pump can
be attached directly to the container of the solution.
OPTIONAL ACCESSORIES:
M10004B pH 4.01 buffer solution, 20 ml sachet (25 pcs)
M10007B pH 7.01 buffer solution, 20 ml sachet (25 pcs)
M10010B pH 10.01 buffer solution, 20 ml sachet (25 pcs)
M10000B Electrode rinse solution, 20 ml sachet (25 pcs)
MA9015 Electrode storage solution, 20 ml sachet (25 pcs)
WARRANTY:
These instruments are warranted from all defects in materials and manufacturing for a period of two years
from the date of purchase. The electrode is warranted for a period of 6 months.
If during this period, the repair or replacement of parts is required, where the damage is not due to negli-
gence or erroneous operation by the user, please return the parts to either dealer or our of ce and the repair
will be effected free of charge.
Note: We reserve the right to modify the design, construction and appearance of our products without ad-
vance notice.
Mount the bracket in the wall in upright position above the water
container (which contains a solution of pH reducing acid and
water).
Place the pump in vertical position (with the tubes below) on the
wall, above and centered with the “Mounting bracket“. Then go
down the pump until it is joined with the bracket.
Connect the pump to the MC122 pH controller (on the black and
white outlet). The pump will discharge 0,08 cL every 2 seconds.
Place the plug and B/W outlet far away from water!
Before servicing (maintenance) on the pump (e.g. changing
tube), please disconnect the equipment.
www.milwaukeeinst.com
MP810 Peristaltic Dosing Pump
• Constant Dosing  ow of 1,5 l/h
(25 cc/min)
• No regulation
• Maximum pressure: 1 bar
• Made of Polipropilene (PP)
• Peristaltic tube in Santoprene
• Power supply: 230 VAC ± 10%
CALIBRATION:
• Remove the protective cap from the electrode.
• Immerse the electrode tip into a new sachet of pH 7 calibration
solution and allow the reading to stabilize.
• Adjust the pH7 calibration trimmer (on the front) to display “7.0
pH”.
• Rinse the electrode with tap water and dry it with paper tissue.
• Open a new sachet of pH 4 calibration solution, immerse the
electrode tip into the sachet and allow the reading to stabilize.
• Adjust the pH4/10 calibration trimmer (on the front) to display
“4.0 pH”.
The calibration is now complete and the meter is ready to take
measurements.
It is suggested to recalibrate the meter at least once a month,
after a prolonged stocking time and after pH-electrode
replacement.
INSTALLATION OF THE
MP810 1,5 L/H DOSING PUMP
Connect the rigid tube to the pump (aspiration – arrow upwards).
Fix the white lter on the other end of the tube, where the dis-
solved pH reducing acid will be drawn in – to prevent small ob-
jects entering the pump.
Connect the soft tube to the pump (impulsion – arrow down-
wards). The injection tting will be placed at the end of this tube
only to inject into a piping. (This tting has a thread that links it
to the piping.)
INSTALLATION OF CONTROLLER:
Connect the supplied 240VAC/12VDC power adapter to the
meter and to the main line.
Connect the connection base (black and white outlet) to the
main line.
Connect the pH-electrode to the BNC socket on the bottom of
the meter.
Always remove the electrode protective cap before taking any
measurement. Make sure that the meter has been calibrated
before taking any measurements
Immerse the tip (2.5 cm) of the pH-electrode into the sample.
(for example it can oat with the help of a piece of polystyrol).
Turn the instrument on by pressing the ON/OFF button.
The nature of the setpoint can be selected by setting the switch
to the desired position (ABOVE or BELOW).
Allow the reading to stabilize and the meter will start continuous
monitoring.
A blinking alarm will indicate when the measured pH value is
higher or lower than selected setpoint, depending on user
selection. When the alarm is activated, it also activates the
connection base and the auxiliary equipment.
The setpoint can be selected by adjusting the central front knob
to the desired value. The selectable range is from 5.5 to 9.5 pH.

Other manuals for MC720

1

Other Milwaukee Controllers manuals

Milwaukee MC311 User manual

Milwaukee

Milwaukee MC311 User manual

Milwaukee 0950-20 User manual

Milwaukee

Milwaukee 0950-20 User manual

Milwaukee DL122 Manual instruction

Milwaukee

Milwaukee DL122 Manual instruction

Milwaukee BLACK BOX DL510 Manual instruction

Milwaukee

Milwaukee BLACK BOX DL510 Manual instruction

Milwaukee MC720 User manual

Milwaukee

Milwaukee MC720 User manual

Milwaukee MC745 User manual

Milwaukee

Milwaukee MC745 User manual

Milwaukee M12 551B-21 User manual

Milwaukee

Milwaukee M12 551B-21 User manual

Milwaukee MC740 User manual

Milwaukee

Milwaukee MC740 User manual

Milwaukee MC510 User manual

Milwaukee

Milwaukee MC510 User manual

Milwaukee MC110 User manual

Milwaukee

Milwaukee MC110 User manual

Popular Controllers manuals by other brands

VIET-TRUNG ALTIVAR 11 user guide

VIET-TRUNG

VIET-TRUNG ALTIVAR 11 user guide

SMC Networks DAS Operation manual

SMC Networks

SMC Networks DAS Operation manual

CUE irCUE user manual

CUE

CUE irCUE user manual

EntraPass KT-400 installation manual

EntraPass

EntraPass KT-400 installation manual

Lenze C520 Commissioning

Lenze

Lenze C520 Commissioning

TyloHelo SaunaChrome Installation and user manual

TyloHelo

TyloHelo SaunaChrome Installation and user manual

Sanyo VSP-3000 Service manual

Sanyo

Sanyo VSP-3000 Service manual

Data Technology 5150CRH installation guide

Data Technology

Data Technology 5150CRH installation guide

Jetter JetMove 200 Series User information

Jetter

Jetter JetMove 200 Series User information

SRS Labs GMC12-WLV-3H24 instruction manual

SRS Labs

SRS Labs GMC12-WLV-3H24 instruction manual

AirTest CN9000 Series manual

AirTest

AirTest CN9000 Series manual

Truma DuoControl vertical operating instructions

Truma

Truma DuoControl vertical operating instructions

KAMEHA KA073 user manual

KAMEHA

KAMEHA KA073 user manual

InPOWER DBT-MDF20 quick start guide

InPOWER

InPOWER DBT-MDF20 quick start guide

Unitronics Samba SM70-J-TA22 installation guide

Unitronics

Unitronics Samba SM70-J-TA22 installation guide

Intiel Dynamic Boiler Controller user manual

Intiel

Intiel Dynamic Boiler Controller user manual

Nice MG3000 Complete manual

Nice

Nice MG3000 Complete manual

Hydor Smart Level user guide

Hydor

Hydor Smart Level user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.