TECHNICAL DATA L4 FFL
Rated power 5.7 W
Lighting time with one fully charged battery
High mode 2 h
Medium mode 4.5 h
Low mode 11.5 h
Luminous flux
High mode 550 lumens
Medium mode 250 lumens
Low mode 100 lumens
Charging time 120 min
Colour rendering index (CRI) 80
Colour temperature 4000 K
Battery voltage 4 V (DC)
USB input 5 V DC; 0.1–2.1 A
Weight 0.18 kg
Weight with battery 0.235 kg
Recommended ambient operating temperature -18 to 50°C
Recommended ambient charging temperature 5 to 40°C
Recommended battery types L4B2
Recommended USB power supply CUSB
Protection class IP54
WARNING! Read all safety warnings, instructions,
illustrations and specifications provided with this power
tool. Failure to follow all instructions listed below may result in
electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
BATTERY-LAMP SAFETY INSTRUCTIONS
Warning! Do not direct the light beam at persons or animals
and do not stare into the light beam yourself (not even from
a distance). Staring into the light beam may result in serious
injury or vision loss.
Do not use this product in wet areas .
The light source of this product is not replaceable; when the
light source reaches its end of life, the whole product shall be
replaced.
BATTERY SAFETY INSTRUCTIONS
Use only MILWAUKEE Type L4B2 rechargeable batteries.
Remove the battery pack before starting any work on the
product.
Do not dispose of used battery packs in the household refuse
or by burning them. MILWAUKEE distributors accept old
batteries to protect our environment.
Do not store the battery pack together with metal objects (short
circuit risk).
Battery acid may leak from damaged batteries under extreme
load or extreme temperatures. In case of contact with battery
acid, wash it off immediately with soap and water. In case
of eye contact, rinse thoroughly for at least 10 minutes and
immediately seek medical attention.
ADDITIONAL BATTERY SAFETY WARNINGS
WARNING! To reduce the risk of fire, personal injury, and
product damage due to a short circuit, never immerse your
tool, battery pack, or charger in fluid or allow a fluid to flow
inside them. Corrosive or conductive fluids, such as seawater,
certain industrial chemicals, and bleach or bleach-containing
products, etc., can cause a short circuit.
SPECIFIED CONDITIONS OF USE
The battery-lamp is intendend to be used as an independent
light source away from the mains supply.
Do not use this product in any other way as stated for normal
use.
CHARGING
Plug your USB cable into a power source such as an AC wall
adaptor, computer or car port.
The indicator light displays the charging status:
●Red solid: charging, 0-79% charged
●Green flashing: charging, 80-99% charged
●Green solid: 100% charged