SPECIFICATIONS
RANGE
MC310 0.0 to 10.0 mS/cm
MC410 0 to 1990 ppm
RESOLUTION
MC310 0 to 1990 mg/L (ppm) / 1mg/L
MC410 10 ppm
ACCURACY
(@25°C) ±2% Full Scale
SETPOINT
MC310 1.0 to 5.0 mS/cm
MC410 100 to 1900 ppm
ALARM
active when the measure
is bellow/above than the
setpoint, in according with
the BELLOW/ABOVE switch
TEMP.
COMPENSATION Automatic, from 0 to 50°C
ENVIRONMENT 0 to 50°C, 95% RH max.
PROBE MA812/2 (included)*
POWER
SUPPLY 12 VDC adapter (included)
DIMENSIONS 148.5 x 82.5 x 32 mm
WEIGHT 180 g (meter only)
(*) To be replace by technical personnel only
CERTIFICATION
Milwaukee Instruments conform to the
CEEuropean Directives.
Disposal of Electrical & Electronic
Equipment. Do not treat this product
as household waste. Hand it over to
the appropriate collection point for the
recycling of electrical and electronic
equipment.
Please note: proper product prevents potential
negative consequences for human health and the
environment. For detailed information, contact your
local household waste disposal service or go to
www.milwaukeeinstruments.com (USA & CAN) or
www.milwaukeeinst.com.
RECOMMENDATION
Before using this product, make sure it is entirely
suitable for your specific application and for the
environment in which it is used. Any modification
introduced by the user to the supplied equipment
may compromise the meter’s performance. For your
and the meter’s safety do not use or store the meter in
hazardous environment. To avoid damage or burn, do
not perform any measurement in microwave ovens.
WARRANTY
These instruments are warranted against defects in
materials and manufacturing for a period of 2years
from the date of purchase. Probe is warranted for
6 months. This warranty is limited to repair or free
of charge replacement if the instrument cannot be
repaired. Damage due to accidents, misuse, tampering
or lack of prescribed maintenance is not covered by
warranty. If service is required, contact your local
Milwaukee Instruments Technical Service. If the repair
is not covered by the warranty, you will be notified of
the charges incurred. When shipping any meter, make
sure it is properly packaged for complete protection.
ISTMC310_11_20
RoHS
COMPLIANT
SATISFACTION
GUARANTEED
OPERATION
yConnect the supplied 12 VDC power adapter to
the meter and to the mains.
yMake sure the meter has been calibrated before
taking any measurements (see Calibration
Procedure).
yImmerse the tip (4cm) of the Conductivity
probe into the sample.
yTurn the instrument on by pressing the ON/OFF
key.
yWait for thermal equilibrium to be reached and
the meter will start continuous monitoring.
ySet the BELLOW / ABOVE alarm activation
switch in the desired position.
yA blinking alarm will indicate when the
measured EC or TDS value is lower/higher
than the setpoint (in accordance the BELLOW
/ ABOVE switch).
SETPOINT
yThe setpoint can be selected by adjusting the
central front knob to the desired value.
yThe selectable range for MC310 is from 1.0 to
5.0 mS/cm.
The selectable range for MC410 is from 700 to
1900 ppm.
CALIBRATION PROCEDURE
yClean the probe with alcohol and let it dry (if a
more thorough cleaning is required, brush the
metal pins with fine sandpaper and then rinse
with water).
yOpen a sachet of suitable conductivity
calibration solution and immerse the probe,
making sure that metal pins are completely
submerged.
Use M10031 (1413 µS/cm) for MC310 and M10442
(1500 ppm) for MC410.
yTurn the meter on by pressing the ON/OFF key.
yWait until the reading stabilize for temperature
variations, and then adjust the EC/TDS
calibration trimmer on the front panel with the
supplied screwdriver until the display shows:
“1413” µS/cm for MC310 and “1500” ppm for
MC410.
The calibration is now complete and the meter is
ready for use.
The instrument should be re-calibrated at least
once a month, or when the probe is changed.
OPTIONAL ACCESSORIES
M10031B 1413 µS/cm cal. solution, 20 mL
sachet (25 pcs)
M10039B 5.00 mS/cm cal. solution, 20 mL
sachet (25 pcs)
M10442B 1500 ppm cal. solution, 20 mL
sachet (25 pcs)
MA812/2 Conductivity probe with 2 m cable

This manual suits for next models

2

Other Milwaukee Measuring Instrument manuals

Milwaukee CD600 User manual

Milwaukee

Milwaukee CD600 User manual

Milwaukee MW11 User manual

Milwaukee

Milwaukee MW11 User manual

Milwaukee 48-22-9802 User manual

Milwaukee

Milwaukee 48-22-9802 User manual

Milwaukee MW13 User manual

Milwaukee

Milwaukee MW13 User manual

Milwaukee MW12 User manual

Milwaukee

Milwaukee MW12 User manual

Milwaukee SM106 User manual

Milwaukee

Milwaukee SM106 User manual

Milwaukee MC125 User manual

Milwaukee

Milwaukee MC125 User manual

Milwaukee LDM 45 User manual

Milwaukee

Milwaukee LDM 45 User manual

Milwaukee MI407 User manual

Milwaukee

Milwaukee MI407 User manual

Milwaukee MW190 MAX User manual

Milwaukee

Milwaukee MW190 MAX User manual

Milwaukee 3712 User manual

Milwaukee

Milwaukee 3712 User manual

Milwaukee 3421 User manual

Milwaukee

Milwaukee 3421 User manual

Milwaukee MR100ATC User manual

Milwaukee

Milwaukee MR100ATC User manual

Milwaukee 48-22-5112 User manual

Milwaukee

Milwaukee 48-22-5112 User manual

Milwaukee MI 404 User manual

Milwaukee

Milwaukee MI 404 User manual

Milwaukee MW14 User manual

Milwaukee

Milwaukee MW14 User manual

Milwaukee LDM 45 User manual

Milwaukee

Milwaukee LDM 45 User manual

Milwaukee SM801 User manual

Milwaukee

Milwaukee SM801 User manual

Milwaukee T75 User manual

Milwaukee

Milwaukee T75 User manual

Milwaukee LDM 30 User manual

Milwaukee

Milwaukee LDM 30 User manual

Milwaukee MI806 User manual

Milwaukee

Milwaukee MI806 User manual

Milwaukee 2205-40 User manual

Milwaukee

Milwaukee 2205-40 User manual

Milwaukee Mi453 User manual

Milwaukee

Milwaukee Mi453 User manual

Milwaukee MA886 User manual

Milwaukee

Milwaukee MA886 User manual

Popular Measuring Instrument manuals by other brands

TE Connectivity 549 Installation and operating instructions

TE Connectivity

TE Connectivity 549 Installation and operating instructions

Lambrecht 8126 X81 operating instructions

Lambrecht

Lambrecht 8126 X81 operating instructions

LaMotte DC1500 FLUORIDE manual

LaMotte

LaMotte DC1500 FLUORIDE manual

Extech Instruments TH10 Guide

Extech Instruments

Extech Instruments TH10 Guide

infrared industries IR208 Operator's manual

infrared industries

infrared industries IR208 Operator's manual

Fluke CertiFiber Pro Getting started guide

Fluke

Fluke CertiFiber Pro Getting started guide

Ronde & Schwarz R&S RT-ZC20 user manual

Ronde & Schwarz

Ronde & Schwarz R&S RT-ZC20 user manual

Triplett 9325 instruction manual

Triplett

Triplett 9325 instruction manual

Franklin Electric Little Giant CONDALERT LC-110 manual

Franklin Electric

Franklin Electric Little Giant CONDALERT LC-110 manual

LaMotte WaterLink Spin Touch DW manual

LaMotte

LaMotte WaterLink Spin Touch DW manual

SICK GM35 operating instructions

SICK

SICK GM35 operating instructions

Sony TC-730 Service manual

Sony

Sony TC-730 Service manual

ABB 4690 Series user guide

ABB

ABB 4690 Series user guide

Seres OL TOPAZ Total Alkalinity Operator's manual

Seres OL

Seres OL TOPAZ Total Alkalinity Operator's manual

Airflow Silent+ Mini Orange instruction manual

Airflow

Airflow Silent+ Mini Orange instruction manual

Faro 6Probe Cleaning and care

Faro

Faro 6Probe Cleaning and care

PCB Piezotronics IMI SENSORS 600A09 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 600A09 Installation and operating manual

Tektronix Keithley SourceMeter 2410 Service manual

Tektronix

Tektronix Keithley SourceMeter 2410 Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.