SPECIFICATIONS
Range 0.00 to 2.50 ppm
Resolution 0.01 ppm
Accuracy ±0.03 ppm ±3% of reading
@ 25 °C
Typical EMC Dev. ±0.01 ppm
Light Source Light Emitting Diode
@525nm
Light Detector Silicon Photocell
Method
Adaptation of USEPA method
330.5. The reaction between
free chlorine and the DPD
reagent causes a pink tint in
the sample.
Environment 0 to 50°C (32 to 122 °F)
max. 95% RH non-condensing
Battery Type 1 x 1.5V AAA
Auto-Shut O After 2 minutes of non-use
Dimensions 87.5 x 63.7 x 35.2 mm
(3.4 x 2.5 x 1.4”)
Weight 65 g (2.29 oz.)
OPTIONAL ACCESSORIES
Reagent Sets
MI526-25 Free Chlorine powder reagent,
25 pcs.
Other Accessories
3000100 Glass cuvettes with caps (2 pcs.)
3000200 Tissue fow wiping cuvettes
(2pcs.)
3000300 1.5V AAA batteries (4 pcs.)
CERTIFICATION
Milwaukee Instruments conform to
the CE European Directives.
Disposal of Electrical & Electronic
Equipment. Do not treat this product
as household waste. Hand it over
to the appropriate collection point
for the recycling of electrical and
electronic equipment.
Disposal of waste batteries. This product
contains batteries. Do not dispose of them with
other household waste. Hand them over to the
appropriate collection point for recycling.
Please note: proper product and battery disposal
prevents potential negative consequences
for human health and the environment. For
detailed information, contact your local
household waste disposal service or go to
www.milwaukeeinstruments.com (USA & CAN)
or www.milwaukeeinst.com.
RECOMMENDATION
Before using this product, make sure it is entirely
suitable for your specific application and for the
environment in which it is used. Any modification
introduced by the user to the supplied equipment
may compromise the meter’s performance. For
your and the meter’s safety do not use or store
the meter in hazardous environment. To avoid
damage or burn, do not perform any measurement
in microwave ovens.
WARRANTY
This instrument is warranted against defects
in materials and manufacturing for a period of
2years from the date of purchase. This warranty
is limited to repair or free of charge replacement if
the instrument cannot be repaired. Damage due to
accidents, misuse, tampering or lack of prescribed
maintenance is not covered by warranty. If
service is required, contact your local Milwaukee
Instruments Technical Service. If the repair is not
covered by the warranty, you will be notified of
the charges incurred. When shipping any meter,
make sure it is properly packaged for complete
protection.
Milwaukee Instruments reserves the right to
make improvements in design, construction and
appearance of its products without advance notice.
ISTMW10 07/20
USER MANUAL
SATISFACTION
GUARANTEED
milwaukeeinstruments.com (USA & CAN)
milwaukeeinst.com
MW10
Digital
FreeChlorine
MiniPhotometer
PRELIMINARY EXAMINATION
Please examine this product carefully. Make
sure that the instrument is not damaged.
If any damage occured during shipment,
please notify your Dealer.
Each MW10 meter is supplied complete with:
yTwo Sample Cuvettes and Caps
ySix powder reagents for Free Chlorine
y1 x 1.5V AAA Battery
yInstruction Manual
FUNCTIONAL DESCRIPTION
1. Dust cover
2. Cuvette with cap
3. Cuvette holder
4. Liquid Crystal Display
5. Button
OPERATION
yTurn the meter on by pressing the button.
After all the segments are displayed, “C.1”,
“Add” appears with “Press” blinking, the
meter is ready.
yFill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the
cuvette into the meter and close the
meter’s cap.
yPress the button. When the display shows
“Add”, “C.2” with “Press” blinking the meter
is zeroed.
yRemove the cuvette, open it and add the
content of one packet of MI526-0 reagent.
Replace the cap and shake gently for
20 seconds. Replace the cuvette into the
meter.
yWait for 1 minute and then press the button
or press and hold the button until the timer
is displayed on the LCD.
yThe instrument directly displays the
concentration of free chlorine in ppm.
The meter automatically turns o after
2minutes.
BATTERY REPLACEMENT
To save the battery, the instrument shuts down
after 2minutes of non-use. One fresh battery
lasts for a minimum of 5000measurements,
depending on the light level. When the
battery capacity is under 10% “bAt” appears
on the LCD at start-up.
If the battery is empty and accurate
measurements can’t be taken any more, the
instrument shows “bAd” then ”bAt” each
for 1 second and turns o. To restart the
instrument, the battery must be replaced with
a fresh one.
To replace the instrument’s battery, follow the
steps:
yTurn the instrument o by holding the
button until the meter shuts o.
yTurn the instrument upside down
and remove the battery cover with a
screwdriver.
yRemove the battery from its location and
replace it with a fresh one.
yInsert the battery cover and replace the
screw with a screwdriver.

Other Milwaukee Measuring Instrument manuals

Milwaukee Mi170 User manual

Milwaukee

Milwaukee Mi170 User manual

Milwaukee MI 413 User manual

Milwaukee

Milwaukee MI 413 User manual

Milwaukee SM100 User manual

Milwaukee

Milwaukee SM100 User manual

Milwaukee LDM 45 User manual

Milwaukee

Milwaukee LDM 45 User manual

Milwaukee M12 3622-20 User manual

Milwaukee

Milwaukee M12 3622-20 User manual

Milwaukee M12 AL User manual

Milwaukee

Milwaukee M12 AL User manual

Milwaukee PH55 User manual

Milwaukee

Milwaukee PH55 User manual

Milwaukee MA871 User manual

Milwaukee

Milwaukee MA871 User manual

Milwaukee MC125 User manual

Milwaukee

Milwaukee MC125 User manual

Milwaukee MI 806 User manual

Milwaukee

Milwaukee MI 806 User manual

Milwaukee PRO Lux MW700 User manual

Milwaukee

Milwaukee PRO Lux MW700 User manual

Milwaukee MA882 User manual

Milwaukee

Milwaukee MA882 User manual

Milwaukee MR32ATC User manual

Milwaukee

Milwaukee MR32ATC User manual

Milwaukee 3631-20 User manual

Milwaukee

Milwaukee 3631-20 User manual

Milwaukee CALIBRATION 2238-20 User manual

Milwaukee

Milwaukee CALIBRATION 2238-20 User manual

Milwaukee MI404 User manual

Milwaukee

Milwaukee MI404 User manual

Milwaukee 2235-40 User manual

Milwaukee

Milwaukee 2235-40 User manual

Milwaukee MW11 User manual

Milwaukee

Milwaukee MW11 User manual

Milwaukee 48-22-5112 User manual

Milwaukee

Milwaukee 48-22-5112 User manual

Milwaukee MW150 User manual

Milwaukee

Milwaukee MW150 User manual

Milwaukee 2205-40 User manual

Milwaukee

Milwaukee 2205-40 User manual

Milwaukee MI405 User manual

Milwaukee

Milwaukee MI405 User manual

Milwaukee CALIBRATION 2238-20 Operating instructions

Milwaukee

Milwaukee CALIBRATION 2238-20 Operating instructions

Milwaukee M12 C4PLA User manual

Milwaukee

Milwaukee M12 C4PLA User manual

Popular Measuring Instrument manuals by other brands

VOLTCRAFT FAS-100 operating instructions

VOLTCRAFT

VOLTCRAFT FAS-100 operating instructions

TPI The Value Leader 716N manual

TPI

TPI The Value Leader 716N manual

Gossen MetraWatt PROFITEST Series Supplement Safety Information

Gossen MetraWatt

Gossen MetraWatt PROFITEST Series Supplement Safety Information

KROHNE WATERFLUX 3000 quick start

KROHNE

KROHNE WATERFLUX 3000 quick start

Novacom CDCS ION instructions

Novacom

Novacom CDCS ION instructions

Hanna Instruments HI96727 instruction manual

Hanna Instruments

Hanna Instruments HI96727 instruction manual

Bio Instruments TIR-4T-V quick start guide

Bio Instruments

Bio Instruments TIR-4T-V quick start guide

NanoSense EP5000M installation manual

NanoSense

NanoSense EP5000M installation manual

Sola HORIZON GREEN BASIC operating instructions

Sola

Sola HORIZON GREEN BASIC operating instructions

Hioki 3151 instruction manual

Hioki

Hioki 3151 instruction manual

CTC Union MX102 Series product manual

CTC Union

CTC Union MX102 Series product manual

SKC Leland Legacy operating instructions

SKC

SKC Leland Legacy operating instructions

OnTarget SW-50C user manual

OnTarget

OnTarget SW-50C user manual

CryptOn DX260 Equipment manual

CryptOn

CryptOn DX260 Equipment manual

Vanguard Instruments TRF-250 user manual

Vanguard Instruments

Vanguard Instruments TRF-250 user manual

Flow vision FC50-EX-CA Instructions for installation and adjustment

Flow vision

Flow vision FC50-EX-CA Instructions for installation and adjustment

Vernier Go Wireless GW-EHR manual

Vernier

Vernier Go Wireless GW-EHR manual

IMR EM 201 instruction manual

IMR

IMR EM 201 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.