Mitel StreamLine Switch Quick Install Guide
Connecting to the Command Line Interface (CLI)
Accessibility:
Console cable connected
directly to the console port
Console Port Serial
Settings:
115200/8/N/1
Default User Name &
Password:
User Name: admin
Password: admin
Connect to the console port:
1. Connect the RJ45 end of the serial cable
to the console port of the StreamLine.
Connect the serial end of the serial
cable to the serial port of your PC.
2. Configure your serial port to
115200/8/N/1
3. Login is “admin”, password is ”admin”
(without quotes)
4. You are now connected to the CLI via
the console port.
Steps to Change the IP Address:
1. Type in “pal-set-sys-ip GbE 192.168.9.1
255.255.255.0 192.168.9.255” Substitute the
provided example IP information for your
own.
a. The usage is: pal-set-sys-ip GbE
<IPADDRESS> <NETMASK>
<BROADCAST>
2. You will be prompted to confirm this
information
3. Refer to the CLI section of the administration
guide for more information.
Changing Management port default IP address
CAUTION: The Mgmt IP default address of 192.168.1.1 may conflict with other network devices/ip addresses. To avoid this
from happening, you must change the IP address of the Mgmt Port to an IP which will not conflict with any other device on
the network. For example, if your network belongs to “192.168.X.X” subnet, change the Mgmt Port IP to “10.10.1.1”.
Steps to Change the Management Port IP Address:
1. Log into the unit via the serial console port (115200,8,N,1,None).
2. Type in “pal-set-sys-ip mgmt 10.10.1.1 255.255.255.0 10.10.1.255”
Substitute the provided example IP information for your own.
a. The usage is: pal-set-sys-ip mgmt <IPADDRESS> <NETMASK> <BROADCAST>
3. You will be prompted to confirm this information.
4. Refer to the CLI section of the administration guide for more information.
NOTE THE FOLLOWING:
All of the above instructions provide basic installation information, necessary for the proper and safe functioning of
this equipment. Persons installing or maintaining this product must read all of the safety instructions and the parts of
system grounding which are applicable to the system being maintained. Only trained, qualified service personnel
shall install or maintain this product.
WARNING: FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN IMPROPER EQUIPMENT
OPERATION AND/OR RISK OF ELECTRICAL SHOCK.
MAKING CHANGES OR MODIFICATIONS
ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY MITEL WILL VOID ANY
COMPLIANCE AND REGULATORY APPROVAL, AND WILL VOID THE USER’S AUTHORITY TO
OPERATE THE EQUIPMENT.
ANY CONNECTION TO AN OUTSIDE PLANT LEAD, AN OFF-PREMISE APPLICATION, OR ANY
OTHER EXPOSED PLANT APPLICATION MAY RESULT IN A FIRE OR SHOCK HAZARD, AND/OR
DEFECTIVE OPERATION, AND/OR EQUIPMENT DAMAGE.
Keep these instructions with the equipment.
Do not attempt to install or service this equipment unless you are skilled in the installation and maintenance of
electronic telecommunications equipment and have successfully completed specific training for this equipment.
6