- 2 -
[ I Electrical Wiring Diagram ]
I Electrical Wiring Diagram
[1] Electrical Wiring Diagram
4
ONOFF
10
1
SW4
SW1
Detection
circuit
*1
L2
ON
4
1
OFF
CNVCC4
(2P)
CNVCC5
(2P)
1
2
1
2
*For more contents displayed on LD1 with other switch settings, see LED monitor display on the outdoor board.
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
3
2
1
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
3
2
1
3
2
1
3
2
1
U
U
W
W
V
V
MC
SLEV
LEV1
Abnormal output
Compressor ON/OFF output
Demand input
Night mode input
Snow sensor input
52
C
CH1
CH2
CH3
63H
SSR
X05
X04
X02
X01
CN20
(7P)
CN32
(3P)
CN33
(6P)
CN35
(3P)
Red
Red
Red
Black
Green
Black
White
White
Black
Red Red
Red
Blue
Red
Red
Red Red
Red
Red
CN34
(6P)
CN38
(3P)
Green Green
CN05
(4P)
CN03
(3P)
CN02
(8P)
CN01
(2P)
CNL
(3P)
TH4 TH3 TH6 TH5 TH8 TH7 TH2 TH1
63LS
CNRS3
(7P)
CNVCC3
(6P)
CNAC3
(5P)
CNLV1
(5P)
CNLV2
(5P)
CN51
(5P)
CN3D
(3P)
CN3S
(3P)
CNRS2
(7P)
CNVCC2
(6P)
CNAC2
(5P)
CN52C
(3P)
CNCT
(4P)
CNDC2
(3P)
CNDR2
(9P)
CN15V2
(14P)
CN15V1
(14P)
CNDR1
(9P)
Yellow
Yellow
CNDC1
(3P)
CNTH
(2P)
CNL2
(2P)
CN30V
(2P)
CNFAN
(3P)
ON
OFF
Factory default
Display of Relay
output 1 (Light ON)
Display of Check 1
(Blink)
Flag 1
Flag 1
Flag 2
Flag 3
Flag 4
Flag 5
Flag 6
Flag 7
Flag 8
Flag 2 Flag 3 Flag 4 Flag 5 Flag 6 Flag 7 Flag 8
Displayed contents when LD1 is lit (blink) Remarks
Operation of SW1
Contents
Compressor
in operation
Crank case
heater 21S4 SV1 SV2 Always
Light ON
Error code display
The error address and the error code are displayed alternately.
Example: Error address 51, Discharge temp. error (Error code 1102)
LD1
<Display of LD1>
LD1
SW1
SWU2
Tens digit Ones digit
SWU1
Unit address setting switch
SV
1
21
S4
SV
2
CNS1
(2P)
CNS2
(3P)
TB3 TB7
Shield
A
ABB
<Operation of SW1 (Self-diagnose switch) on Control Board and Displayed Contents on LD1>
*1 part might not exist.
MF
1
THHS L2 R2
DCCT
MF
5
4
3
2
1
CNFAN1
(5P)
Gate amp board
(G/A PKG)
IPM
Control board
(MAIN PKG) INV board
(INV PKG)
Red
Red
White
White
Green
Blue
Red
Red
Blue
Blue
Blue
12V
DSA ZNR1~4
Centralized power supply
CN41
(4P)
CN40
(4P)
1
F1
6A
F2
6A
F01
2A
1
2
3
RSTE
E
T
R
E
T
R
R1
52C
POWER-BOARD
FN1 FN3
FN2
FN6
FN4
DCL
C1
+
P
N
F01
3A
LED1
LED2
LED3
SW2SW3
1
10
1
10
1
10
OFF ONOFF ONOFF ON
63HS
CNH
(3P)
TH9
CN06
(2P)
TH10
CN09
(2P)
63HS High pressure sensor
LEV1
SLEV
THHS
63LS
Choke coil (Transmission)
Electronic expansion valve (SC coil)
Electronic expansion valve (Oil return)
Low pressure sensor
Thermistor (Radiator plate)
Thermistor (Liquid outlet temp. detection at Sub-Cool coil bypass)
TH8
Thermistor (Shell temp. detection at compressor)
Thermistor (Liquid temp. detection at CS circuit)
DC Current Sensor (Direct Current)
Resistance of rush current prevention
Bleeder resistance
Main capacitor (smooth)
Electro-magnetic contactor (Inverter main circuit)
Motor for compressor
Motor Fan (Radiator plate)
Crank case heater (Compressor)
Four-way valve
Solenoid valve (Discharge-suction bypass)
High pressure switch
Thermistor (Discharge piping temp. detection)
Thermistor (Saturation evaporation temp. detection)
Thermistor (Liquid level detection of accumulator, lower)
Thermistor (Liquid level detection of accumulator, upper)
Thermistor (OA temp. detection)
Thermistor (Piping temp. detection)
Thermistor (Liquid outlet temp. detection at Sub-Cool coil)
Terminal block for power supply
Terminal block for transmission line (For indoor series)
Terminal block for transmission line (For centralized administration)
Earth terminal
Code heater (Liquid level detection of accumulator)
DCCT
R1
R2
C1
52C
MC
MF1
CH1
SV1,SV2
21S4
63H
TH1
TH2
TH3
TH4
TH5
TH6
TH7
TB1
TB3
TB7
CH2,CH3
Symbol Symbol Symbol Symbol
Name Name Name Name
E
MF Motor Fan (Heat exchanger)
TH10
TH9
Note: Refer to the list shown above for switch settings.
Unit plate
Controller
box plate
E
Connecting to the
indoor unit, remote
controller
TB1
R
S
T
DS (Diode stack)
+
-
Power source
200V 3 phase
50/60Hz
5
4
3
2
1
2
12
3
123
4
1234
1
1
2
12
1212
0
3
123
123
123
4675891234 67589
1234 67589
11
11111111
1
22
22222222
33
33333
3
4467
7
5
5
8
111210 1314
12 3 4 67589111210 1314
1234
1234
ON
OFF
SW3-10
Model
P200
P250
Flag 8 stays lit while power supply
of the microcomputer is turned on.
1234 6758910
Operation
Error
Charge