1 SafetyPrecautions
2 MakingSureofComponents
5 Installationofremotecontrolholder
3 Beforeinstallation
4 Installationofwirelessreceivingunit
・Incompleteinstallationcouldcauseelectricshock,fire,etc.
・Afterusingthismanual,besuretopassittothecustomertogetherwiththeinstructionmanualprovidedwithindoorunit.Askthecustomertokeepthisinstallationmanualandthe
instructionmanualinahandyplace,andtoshowthemtotheengineerwhentheair-conditionerismovedorrepaired.Alsoaskthecustomertopassthemtoanynewuser.
・Readthese"safetyPrecautions"thoroughlyandinstallsecurely.
・Precautionsareclassifiedusingthefollowingsymbolsdependingontheextentandtypeofdangerbyerroneoushandling.
Makesurethatthefollowingcomponents,alongwiththismanual,are
packedinthebox.
●Opentheintakegrillandremovethecornerpanelwhererefrigerantpipesareandwherelocalwiresare
drawninto.
※Thecornerpanelremovedisnotneeded.
●Remove the thermistor for room temperature fixed by 1 screw and the control box cover fixed by 3
screws,whichispossibletohangtemporarily.
Remotecontrolholdercanbeusedforkeepingtheremotecontrolleronthewall.
Fittingremotecontrollerintoholder
①Fixtheremotecontrolholdertothewallusing
thetwowoodscrewsprovided.
②Inserttheremotecontrollerintotheholder.
Removingremotecontrol
●Pullouttheremotecontroller.
●Bring the cable of wireless receiving unit through the square hole
underneaththecornerpanelremovedwhererefrigerantpipesareand
wherelocalwiresaredrawninto.
●Asshowninthefigure,pullthecableintotheinsideofthecontrolbox
and connect it to CN90 on the indoor controller board. Then fix the
cablebytheclamp,beingabletoremovethereceivingunitafterwardsin
case.
●Slidethereceivingunitinthe directionasshownandfixit bythe
screwwhichisusedforthecornerpanelremoved.
●Aftertheinstallationcompleted,setthecontrolboxandthethermistor
astheywere.
・Incompleteinstallationcouldcauseelectricshock,fire,etc.
・Otherwise,theunitcouldfall,whichcouldcauseinjury.
・Shortageinelectricalcircuitcapacityorincompleteconstructioncouldcausefire,etc.
・Modificationorincorrectrepaircouldcauseelectricshock,fire,etc.Consultthedealer
fromwhomyoupurchasedtheunit.
・Incompleteinstallationcouldcauseelectricshock,fire,etc.Askthedealeroraspecialist
forinstallation.
・Tensiononwirescoulddisconnectthem,orcauseheat,fire,etc.
・Doingsocouldcausefault,electricshock,etc.
・Failuretodosocouldcausefault,electricshock,etc.
・Failuretodosocouldcausefault,electricshock,etc.
・Failuretodosocouldcausefault,fire,etc.
・Usageinaplacewherethereismuchoil(includingmachineoil),steam,sulfidegas,
etc.couldgreatlydegradeitsperformanceordamagecomponents.
・Thisunitcouldmalfunctionwhenaffectedbyinverterequipment,privateelectricgenerator,high-frequencymedicalinstruments,radiocommunicationdevices,etc.Also,thisunit
couldadverselyaffectmedicalinstruments,communicationdevices,etc.,thusinterferingwithhumanmedicaltreatment,orcausingdisturbanceinbroadcastpicturesornoise.
・Ifgasleaksoraccumulatesaroundtheunit,itcouldcauseignition,explosion,etc.
・Avoidinstallinginawallwherecondensationoccurs.Installinginsuchaplacecould
causeafault,electricshock,etc.
・Installinginsuchaplacecouldcausefault,electricshock,etc.
!
"
#
・Incompleteconnectionorfixingcouldcauseheat,fire,etc.
$
$
・Installinginsuchaplacecouldcausedeformation,fault,etc.
%&
℃
&
℃
$
CAUTION
WARNING
CAUTION
WARNING Erroneoushandlingcancausedeathorseriousinjury.
ThismanualdescribestheinstallationforwirelessremotecontrolleroftheMitsubishipackageair-conditioner.
Readthismanualorunit'sinstallationmanualcarefully.
MitsubishiPackageAir-Conditioner
InstallationManual
Erroneoushandlingcancausepersonalinjuryordamage.
WirelessRemoteControllerKit
PAR-SW96U-E
Component
WirelessReceivingUnit(CornerPanel)
Wirelessremotecontroller
Remotecontrolholder
"AAA"LR03alkalinebatteries
4.1x16woodscrews
1
1
1
2
2
PAR−SW96U−E
NoteTheremotesignalwillreachthereceiveroveradistanceofapprox.7minastraight
lineandapprox.45゜leftorright.Iftheinfraredreceiverisaffectedbyfluorescentlight
(especially,invertertype),itmaynotbeabletoreceivethesignal.Takethisinto
considerationwheninstallingfluorescentlightsorreplacingthem.
WirelessReceivingUnit
(CornerPanel)
Screw
IndoorController
BoardCN90 Cable
Cramp
Squarehole
ペアNO
.
J41
J42
IndoorUnit
Grill
Refrigerantpipes
CornerPanel
Screw
Screw
Screw
Indoor
Controller
Board
JumperWire
Cont.BoxCover
IntakeGrill
IntakeSensor
※Turnoffthemainpowerbeforework.
RG79D052H01