19
9-7. TIMER OPERATION
1. How to set the time
(1) Press STOP/OPERATE (OFF/ON) (MLZ-KA·VA- E4 , ER4 )/OPERATE/STOP (ON/OFF) (MLZ-KA·VA- E1 , E2 , E3 ,
ER3 ) button to start the air conditioner.
(2) Check that the current time is set correctly.
NOTE: Timer operation will not work without setting the current time. Initially “AM0:00” blinks at the current time display
of TIME MONITOR, so set the current time correctly with CLOCK SET button.
How to set the current time
(1) Press the CLOCK set button.
(2) Press the TIME SET buttons ( and ) to set the current time.
• Each time FORWARD button ( ) is pressed, the set time increases by 1 minute, and each time BACKWARD button
( ) is pressed, the set time decreases by 1 minute.
• Pressing those buttons longer increases/decreases the set time by 10 minutes.
Press the CLOCK set button.
2. Vertical vane
(1) Press WIDE VANE button to change horizontal airflow direction.
•The vertical vane moves for about 30 seconds.
(After 30 seconds, the vertical vane moves to its original position. In this case, press WIDE VANE button again.)
(2) Press WIDE VANE button again to set horizontal airflow direction.
•The vertical vane stops and the airflow direction is set.
(3) Positioning
To confirm the standard position, the vane moves until it touches the vane stopper. Then the vane set to the desired
angle.
Confirming of standard position is performed in the following cases:
(a) When STOP/OPERATE (OFF/ON) (MLZ-KA·VA- E4 , ER4 )/OPERATE/STOP (ON/OFF) (MLZ-KA·VA- E1 , E2 , E3 ,
ER3 ) button is pressed (POWER ON).
(b) When SWING is started.
9-6. DRAIN PUMP/ FLOAT SENSOR CONTROL
1. Drain pump
Operating condition:
1. During COOL, DRY, or emergency COOL operation
2. When float sensor detects water level above fixed point during:
(a) HEAT operation.
(b) emergency HEAT operation.
(c) standby when during multi system operation.
(d) standby when ON timer is set.
(e) operation STOP.
Drain pump operates in conditions 1 or 2.
Operation stop condition:
Condition other than 1 or 2 indicated above.
2. Float sensor
Float moves with the up and down of water surface inside the drain pan, and judges water level.
(Fixed point differs at raised and lowered water levels.)
Float sensor
Water surface
Fixed point, when water level rises
Fixed point, when water level lowers
ON timer setting
(1) Press ON-TIMER button ( ) during operation.
(2) Set the time of the timer using TIME SET buttons ( and ) .
OFF timer setting
(1) Press OFF-TIMER button ( ) during operation.
(2) Set the time of the timer using TIME SET buttons ( and ).
Each time FORWARD button ( ) is pressed, the set time increases by 10 minutes; each time BACKWARD button
( ) is pressed, the set time decreases by 10 minutes.