manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MOEM
  6. •
  7. Safe
  8. •
  9. MOEM 10G Series User manual

MOEM 10G Series User manual

Popular Safe manuals by other brands

Euromate 406210 Original instructions

Euromate

Euromate 406210 Original instructions

SPORTS AFIELD PRESERVE SA72-60WD instruction manual

SPORTS AFIELD

SPORTS AFIELD PRESERVE SA72-60WD instruction manual

Squire Stronghold Keysafe Fitting instructions

Squire

Squire Stronghold Keysafe Fitting instructions

Phoenix FS0352C Instructions & Guarantee Registration

Phoenix

Phoenix FS0352C Instructions & Guarantee Registration

Hornady SnapSafe Trunk Safe II owner's manual

Hornady

Hornady SnapSafe Trunk Safe II owner's manual

Phoenix KS0030E Series operating instructions

Phoenix

Phoenix KS0030E Series operating instructions

Vaultek 10 Series Quick setup

Vaultek

Vaultek 10 Series Quick setup

Arregui CLASS operating instructions

Arregui

Arregui CLASS operating instructions

Technomax Trony Series Instruction handbook

Technomax

Technomax Trony Series Instruction handbook

SPORTS AFIELD INSTINCT BIOMETRIC Series instruction manual

SPORTS AFIELD

SPORTS AFIELD INSTINCT BIOMETRIC Series instruction manual

SPORTS AFIELD SA-HD5-BIO instruction manual

SPORTS AFIELD

SPORTS AFIELD SA-HD5-BIO instruction manual

Olymp GOsafe 110 operating instructions

Olymp

Olymp GOsafe 110 operating instructions

Phoenix SS0100E Operating Instructions & Guarantee Registration

Phoenix

Phoenix SS0100E Operating Instructions & Guarantee Registration

Ankaro ANK EZ I quick start guide

Ankaro

Ankaro ANK EZ I quick start guide

Honeywell 2077D - 1.21 Cubic Foot Anti-Theft Safe user guide

Honeywell

Honeywell 2077D - 1.21 Cubic Foot Anti-Theft Safe user guide

Beaumont SMART KEYBOX user guide

Beaumont

Beaumont SMART KEYBOX user guide

Phoenix FS1270E Series operating instructions

Phoenix

Phoenix FS1270E Series operating instructions

Shure T-Wall Series Assembly instructions

Shure

Shure T-Wall Series Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

!!!Instruction!Manual!(10G!Series)!
IMPORTANT!!:
PLEASE READ COMPLETE INSTRUCTIONS BEFORE OPERATING THE LOCK
Usage for guest
When first use the default factory code is 1680
Lock:
Close the door and hold on, input 4 to 6 digit code and press
“Enter”(within 5 mins after unlocking press “Enter” to lock
directly, the old code unchanged)
Unlock:
Input guest code and press “Enter”, the door will open
automatically.
Note:
• “Cancel” can be used to delete the code in the process of
inputting;
• Press “Cancel” before input, the code will not be shown but
instead of “-“;
• Concessive 3 times error entry, the operation is frozen for
about 5 minutes.
Usage for administrator
1. Check battery capacity:
When the safe is locked press “Enter”, “BATT-H”
indicate batteries are normal, “BATT-L” indicates
batteries are insufficient , for security and normal use
please change batteries as quick as possible. The
discarded batteries should be disposed eco-friendly!
2. The following functions are carried out under
administrator mode
To enter administrator mode:
Double press “Cancel” quickly, the screen displays “SUPER”,
input current administrator code, press “Enter”.
Note: Default factory administrator code is “000000”.
To open
In the administrator mode input operation code “00”, and
press “Enter” ,the door will open automatically.
To modify administrator code:
In the administrator mode:
a. Input operation code “01”, press “Enter”, the screen
displays “NEW”;
b. Input 6 digit new administrator code, press “Enter”,
the screen displays “REPEAT”;
c. Input new code again, press “Enter”, the screen
displays “GOOD”, modification is completed.
To modify unlocking records data and time:
The data and time is used in internal control board for
unlocking record, to ensure the correction of the unlocking
record, when first use and after changing the batteries please
set the data and time.
a. Input operation code “08”, press “Enter”, the screens
shows “SET-DT”;
b. Then the screen shows the date message, the format
is “YYMMDD”, YY is year, MM is month, DD is day, for
example 2008-10-20, input 081020
c. Input date and press “Enter”;
d. The screen shows time message, the format is
“hhmmss”, hh is hour, mm is minute, ss is second
e. Input the time and press “Enter”
f. The screen shows “GOOD”.
To check the unlocking record:
A record is shown in two screens, the first screen displays
date message, the format is “YYMMDD”, YY is year, MM is
month, DD is day, the second screen shows the time message
and opening method, the format is “hhmm-x”, hh is hour, mm
is minute, x is as following:
1 - open by administrator
7 - open by CEU
8 - open by guest code
9 - open by override key
In the administrator mode:
a. Input operating code “09”, press “Enter”
b. The first screen message of the latest record is shown
At this time the key function is as followed:
2 - to previous record
8 - to next record
4 - to the first screen of a record
6 - to the second screen of a record
5 - to the latest record
C - to exit browsing record
Other key - factory reserved.
To exit administrator mode:
When the screen displays “CC--” press “Cancel”.
Forget the administrator code
a. Open the safe with mechanical key or guest code;
b. Remove the back cover of the door;
c. Press and hold “RESET” button in control board;
d. Wait for about 7 seconds until screen displays
“RESET”, release the button;
e. Install the back cover of the door, the administrator
code is restored to “000000”;
f. Please refer to Usage for administrator 2 to modify
administrator code.