
S1/S2
DIP Switch
S1=OFF
S2=OFF
S1=ON
S2=OFF
S1=OFF
S2=ON
S1=ON
S2=ON
1st DIP 2nd DIP 3rd DIP Alarm Stage 1 Alarm Stage 2 Alarm Stage 3 Alarm Stage 4
0 0 0(1) OFF Flash
60 (75) times/min
Flash
75 (90) times/min
Steady light
1 0 0(1) OFF Rotary
60 (75) times/min
Rotary
75 (90) times/min
Steady light
0 1 0(1) OFF Triple Flash
60 (75) times/min
Triple Flash
75 (90) times/min
Triple Flash
100 (120) times/min
1 1 0(1) OFF Flash & Rotary
60 (75) times/min
Flash & Rotary
75 (90) times/min
Flash & Rotary
100 (120) times/min
Removal of End Cover
Caution Ensure beacon is isolated from supply before removing cover.
Unscrew the four (4) M4 retained hex socket head screws. This will release the cover from the base and
allow the cover to hang on the retaining wire strap. Before replacing the cover, check that the joints are
clean and not damaged and that the gasket is still retained in the groove.
6.0 Status and Frequency Adjustment
DIP switches mounted on the PCB, 3 pole (LED450), 2 pole (X450) allow the frequency to be set
Binary code is 0=Off and 1=On. Alarm stages are managed via remote switching between S0 & S1 &
S2. Refer to Diagram 2 & Table 1 & Table 2. Dc units connect +v to terminal marked ‘L’.
Do not connect Ac or Dc to terminals S0, S1 & S2.
1.0 Introduction The LED450/X450 series are weatherproof beacons designed according to EN54 (BS 5839)
standard. The enclosure is a composite material of PC (Polycarbonate) and Fibreglass. The unique design
allows different Flash and Rotary rates, including Steady with the LED450 Beacon and Flash rates with the
X450 (Xenon) beacon.
Lens Colour Selection
01 = Amber, 02 = Red, 03 = Blue, 04 = Green, 05 = Clear.
2.0 Labelling Refer to label for Beacon Type, Voltage Type and Batch Code detail.
3.0 Temperature Classication Ambient temperature range -40 0C to +70 0C
4.0 Installation
General Requirement
The product must be installed in accordance with the latest issued relevant requirements in the EN54 (BS 5839)
standard. Product installation must be carried out in accordance with any local codes that may apply and should
only be carried out by a competent electrical engineer.
Location The location of the unit should be made with due regard to the area over which the beacon warning
signal must be visible. The unit should only be xed to services that can carry the weight of the unit.
Mounting The products should be mounted on a vertical surface using four (4) xing holes in the
base. The xing holes are designed to t M5 Allen Screw only. Use of stainless steel fastener is recommended
by Moash. The beacon can be operated in any attitude. Refer to Diagram 1 for detail.
5.0 Wiring
General Requirement
Moash recommends that all cables and cores should be fully identied (suggest using cable from 1.5mm to
2.5mm2). Ensure that all nuts, bolts and screws are secured. Ensure that only the right and certied cable glands
are used and earthed correctly. Ensure correct cable glands and stopping plug are used to maintain IP rating.
Moash recommends SS316L for this application.
Cable Connection Should be carried out in accordance with relevant technical requirement.
Diagram 2
Diagram 1
105.0
105.0
84.9
84.9
4-Ø5.6
FIX HOLE
136.5
68.0
8.0
28.0
CABLE ENTRIES (x4)
POWER OUT POWER IN
L N E
L N E
TYPICAL PCB
L SO S2
N S1
DIP Switch
(2/3 pole)
(Xenon / LED)
1 2 3
ON
END COVER
SCREWS
M4
105.0
105.0
84.9
84.9
4-Ø5.6
FIX HOLE
136.5
68.0
8.0
28.0
CABLE ENTRIES (x4)
POWER OUT POWER IN
L N E
L N E
TYPICAL PCB
L SO S2
N S1
DIP Switch
(2/3 pole)
(Xenon / LED)
1 2 3
ON
END COVER
SCREWS
M4
105.0
105.0
84.9
84.9
4-Ø5.6
FIX HOLE
136.5
68.0
8.0
28.0
CABLE ENTRIES (x4)
POWER OUT POWER IN
L N E
L N E
TYPICAL PCB
L SO S2
N S1
DIP Switch
(2/3 pole)
(Xenon / LED)
1 2 3
ON
Code Voltage Light Source Current
LED450-18 12-48v Dc --- 10 W 0.53 @ 24v
LED450-22 100-240v Ac ~ 10 W 0.08 @ 230v
X450-18 12-48v Dc --- 10 J 0.49 @ 24v
X450-22 100-240v Ac ~ 10 J 0.06 @ 230v
Table 1 - LED Beacon Frequency and Status Selection
L N S0 S1 S2
On O
Alarm stage selection
LED/X450 BEACON
Live (+)
Neutral (0)
S1/S2
DIP Switch
S1=OFF
S2=OFF
S1=ON
S2=OFF
S1=OFF
S2=ON
S1=ON
S2=ON
1st DIP 2nd DIP Alarm Stage 1 Alarm Stage 2 Alarm Stage 3 Alarm Stage 4
0 0 OFF 60 times/min (1) 90 times/min (1) 120 times/min (1)
1 0 OFF 60 times/min (2) 60 times/min (3) 60 times/min (4)
0 1 OFF 60 times/min (3) 60 times/min (4) 60 times/min (5)
1 1 OFF 60 times/min (4) 60 times/min (5) 60 times/min (6)
Table 2 - Xenon Beacon Frequency and Status Selection
All values in ( ) are the numbers of ashes per time
Values in ( ) rate when 3rd DIP (1) On