One Product Features:
·Main board adopts Philips CPU and microcomputer chip-level.
·TDG anti-theft cylinder(easy to replace of anti-theft mechanical cylinder)
·Modern and fashion style
·Optional unlocking modes(Password or card, password only, card only, card+password)
·When illegal attack happened lock password to protect and give a alarm.
·Can manage cards by passwords
·With function of anti-peeped passwords.
·TDG anti-theft cylinder can replace of normal standard anti-theft door lock cylinder.
Two Technology Specification
More than 300,000 times
Available cards RF card
Cards testing method Microwave test, reliable and advanced
Password numbers 200 groups
Card numbers 780 pcs
Power supplier DC4.5V~6.5V, 4pcs 1.5V“AA” alkaline batteries
Static current < 15μA
Dynamic current < 150mA
Low voltage warning function Have sound lighting notice when voltage low
than 4.8V,, still can open 50 times.
Electric actuator DC micro motor
Available cylinder Standard anti-theft door use TDG electronic
cylinder
Service life
Three Function and Operation
Product Original Status
Initial user password is "123456".
Initial management passwords is “0000” (Management passwords cannot unlock the lock).
1 2
1). Change the management passwords.
“*7” + management passwords + # + new management passwords + #. Setting finished.
Remarks: New management passwords will replace the old one.
Atten.: The correct operation of “*7”:Use one finger press *, then another finger press 7,
then release both buttons at the same time. Same operation for “*8”, “*9”, “*0”, “*1”.
2). Change the management card.
“*7” + management passwords + # + new management card + #. Setting finished.
Remarks: New management card will replace the old one.
We named “Read management card” or “Input management passwords” to “management
key” in the following instructions.
3). Add new user cards or new user passwords.
Add new user cards: “*8” + management key + # + new card + #.
Repeat for more user cards.
Add new user passwords: “*8” + management key + # + new passwords + #.
Repeat for more user passwords.
The function can input many user cards continuously, or input many user passwords;
The function will exit automatically after 6 seconds, or you can press “#” to exit operation
directly.
4). Delete user cards or user passwords.
Delete user cards: “*9” + management key + # + user card + #.
Repeat to delete more user cards.
Delete user passwords: “*9” + management key + # + user passwords + #.
Repeat to delete more user passwords.
The function can delete many user cards continuously, or delete many user passwords;
The function will exit automatically after 6 seconds, or you can press “#” to exit
operation directly.
5). Delete function
a. Factory reset: “*0” + management key + # + 0 + 0 + #.
b. Delete all user passwords and user cards: “*0” + management key + # + 0 + 1 + #.
c. Delete all user cards: “*0” + management key + # + 0 + 2 + #.
d. Delete all user passwords: “*0” + management key + # + 0 + 3 + #.

6). Unlock Mode and Mode Setting
Remarks: Default Mode is Mode (1).
Mode(1): Password mode or Card mode. Unlock the lock by any valid password or card.
Setting: “*0” + management key + # + 1 + 0 + #.
Mode(2): Coordination unlocking of approval by valid user card and valid user password.
It is OK to read the valid card first or input the valid password first.
Setting: “*0” + management key + # + 1 + 3 + #.
7). Passage Mode
Passage Mode Setting: “*0” + management key + # + 2 + 1 + #.
Passage Mode Open: “*0” + management key + # + 2 + 1 + # + user card or user passwords
+ “*1” (one sound). Setting finished.
Based on above open mode, continue to touch user card or input user passwords or press
“#” to close passage mode.
8). Others
a. Alarm whistle 10 times after inputting error password 3 times, alarm whistle 10 times and
keyboard will be locked for 1 minute after error password 7 times.
b. Protect your passwords by using one group of numbers which includes the user
passwords: When you use passwords to open door, input passwords as per method: xxx +
user passwords + xxx + “*#”. It means that after press button“*#” to confirm, you can add
several unrelated passwords in front or after user passwords.
Remark: User passwords must be entered and must be within the last 31 numbers.
c. Factory setup: Dismantle batteries cover of back panel, press ADEL button for 3 seconds,
then red lamp lighting, and make a long sound, the system start to recover factory setup,
memory, all cards and passwords records are completely deleted, finally admin password
is“0000”, passage mode, working mode is mode 1.
d. Press“*” singly means “cancel”, press “#” singly means “confirm”, press “*#” means
“confirm”.
34
9). Identify Indicating Voice
“do na mi” open lock\close lock
“di” short voice: pressing button voice
“di…”: key or normal opening is valid
“di……”long voice: start to delete lock information
“di”4 times: working mode is not matched
“di da”: valid password or valid card
“di da di da”: password or card setup is valid
“warning alarm” 1 time: password or card is invalid
“warning alarm” 2 time: lock do not close fine
“warning”10 times input error password 3 times
“warning”10 times +1min keypad locked input error password more than 7 times.

Four Size:
56
240
Five Notes:
1. Factory code”123456” is set to facilitate opening door when installation, it will be invalid
after delete all information of lock.
2. Can change the outward or inward opening for cylinder, see pic.
Other Molilock Door Lock manuals