2
For accessories and additional info go to: www.mosquitomagnet.com
1
American Biophysics 1-877-699-8727
Safety Instructions
Please read and follow all safety
instructions and warnings.
For your safety if you smell gas:
1. Shut off the gas to your Liberty Plus.
2. Extinguish any open flame.
3. If odor continues, immediately call
your gas supplier.
4. Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
5. The Liberty Plus is for outdoor use
only. If stored indoors detach and
leave propane cylinder outdoors
at all times.
Note: Some or all of the following required safety
instructions for propane powered devices may apply
to your Liberty Plus.
Warning: Improper installation, adjustment,
alteration, service or maintenance can cause injury or
property damage. Read the installation, operating and
maintenance instructions thoroughly before installing
or servicing the Liberty Plus.
Caution: The gas pressure regulator provided with this
appliance must be used. This regulator is set for an outlet
pressure of 11.0 in. Water Column. The minimum inlet gas
supply pressure is 11” WC from regulator.
•The gas supply must be turned off at the LP-Gas supply cylinder
when this appliance is not in use.
•The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.
1-1998 for US and with the CAN1-B149 for Canada.
•To test for a gas leak, place soapy water around the regulator.
If bubbles appear, there is a gas leak.
•The hose assembly must be replaced prior to the appliance being
put into operation if there is evidence of excessive abrasion or
wear, or if the hose is damaged. The instructions shall state that
the replacement hose assembly shall be that specified by the
manufacturer.
•The Liberty Plus is equipped with an internal hot surface ignition
device. Failure to follow starting procedure will result in the trap
not starting.
•Installation and repair should be done by a qualified service person.
The heater should be inspected before use and at least annually by
a qualified service person. More frequent cleaning may be required
as necessary. It is imperative that the control compartment,
burners, and circulating air passageways of the heater be kept
clean.
•Adequate clearances of 20” – 24” around air openings into the
combustion chamber, clearances from combustible material,
provisions for accessibility and for combustion and ventilating
air supply. Keep the Liberty Plus area clear and free from
combustible materials, gasoline, and other flammable vapors
and liquids. The appliance is not to be used in locations where
flammable vapor or explosive dust is likely to exist.
•Do not obstruct the flow of combustion and ventilation air.
•Keep the ventilating openings of the cylinder enclosure
free and clear from debris.
•Clean the Liberty Plus with a water damp cloth, if necessary.
•A maximum of a 20 lb. LP-Gas cylinder shall be used.
Model No.: Liberty Plus
Serial No.:
Type of Gas: Propane
Manifold Pressure: 100 – 110 psi
Minimum Gas Supply Pressure: 11.0 in. WC
Input Rating: 650 Btu/Hr.
Minimum Clearances: 20 – 24”
Contents
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Principle Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Additional Components . . . . . . . . . . . . . . . . . . . . . . . . . .4
Assembly Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7
Charging trap
Trap Placement
Propane Tank Installation
Tank Changing Tips
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Starting Instructions
Shut-Down Instructions
For Best Results
Quick Clear Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11
LED Fault Codes
Gas Reset Tool
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
How the Mosquito Magnet®Works
Mosquitoes and other biting insects use the long-range
attractant carbon dioxide (CO2) to locate people. Once in close
proximity, mosquitoes use short-range attractants such as
scents emitted from the skin, to determine which person they
are going to bite. The Mosquito Magnet®mimics a human
by converting propane to CO2, with its patented catalytic
conversion technology, in combination with a short-range
attractant (patent pending).
Attracted by the CO2and short-range attractant, mosquitoes
and other biting insects are drawn to the Mosquito Magnet®.
When they reach the trap, the insects are vacuumed into
a net by our patented Counterflow Technology™, where they
dehydrate and die within 24 hours.
The Mosquito Magnet®is silent and odorless. When properly
placed in your yard, the trap begins working immediately.
Noticeable results can be achieved in 7 to 10 days. To greatly
reduce your biting insect population, allow 4 – 6 weeks. Leave
the Mosquito Magnet®out all summer long, to control the
mosquito population in your yard.
Only biting insects are targeted including mosquitoes,
no-see-ums, black flies and biting midges, not beneficial
insects such as butterflies, bees or moths.
Questions or Comments
Please contact American Biophysics®Corporation if you
have any questions or experience any problems with your
Mosquito Magnet: 1-877-699-8727
American Biophysics Corporation
140 Frenchtown Rd.
North Kingstown, RI 02852
P: 401-884-3500
F: 401-884-6688
www.mosquitomagnet.com
Counterflow TechnologyTM
Children and adults should be
alerted to the hazards of high surface
temperatures and should stay away
to avoid burns or clothing ignition.
Young children should be carefully
supervised when they are in the
area of the heater. Keep out of reach
of children.
Clothing or other flammable materials
should not be hung from the heater,
or placed on or near the heater.