Wiring the Redundant Power Inputs
The IKS-6324 switch has two sets of power input—power input 1
and power input 2.
Insert the dual set positive/negative DC wires into PWR1
and PWR2 terminals (+ pins 1, 9, -
insert the L/N AC wires into the PWR1 terminals (L
1, N pin 2).
To keep the DC or AC wires from pulling loose, use a
screwdriver to tighten the wire-
clamp screws on the front
of the terminal block connector.
LED Indicators
The front panel of the IKS
-6324 switch
contains several LED indicators. The
function of each LED is described in the
table below.
STAT
GREEN
On
System has passed self-diagnosis
test on boot-up and is ready to
Blinking System is undergoing the
RED On
System failed self-diagnosis on
boot-up.
PWR1 AMBER
On
Power is being supplied to the
main module’s power input PWR1.
Off
Power is not being supplied to the
main module’s power input PWR1.
PWR2 AMBER
On
Power is being supplied to the
main module’s power input PWR2.
Off
Power is not being supplied to the
main module’s power input PWR2.
FAULT RED
System initiation has failed.
System initiation was successful.
NOTE: Use the Mode push-button switch to cycle among the
LNK/ACT, SPEED, and FDX/HDX LEDs. The status of these three
settings is indicated by the LEDs for the various ports. The system
will switch to LNK/ACT automatically after 5 seconds.
LNK/ACT GREEN
On
The corresponding module port’s
link is active.
Blinking The corresponding module port’s
data is being transmitted.
Off
The corresponding module port’s
link is inactive.
SPEED GREEN
Off
The corresponding module port’s
data is being transmitted at 10
On
The corresponding module port’s
data is being transmitted at 100
Blinking
The corresponding module port’s
data is being transmitted at
FDX/HDX
GREEN
On
The corresponding module port’s
data is being transmitted at full
Off
The corresponding module port’s
data is being transmitted at half
* Slot 1 (M1) is mainly used for Gigabit modules. If 100BaseFX
modules are used in Slot 1 (M1), the modules will not support “Far
End Fault”. The Link/ACT LED indicator will stay at “Green (ON)”
status when Fiber TX cable is unplugged.
Specifications
IEEE802.3, 802.3u, 802.3ab, 802.3z, 802.3x
IEEE802.3x flow control, back pressure flow
control
10/100BaseT(X) or 100BaseFX (SC/ST
connector)
10/100/1000BaseT(X),
1000BaseSX/LX/LHX/ZX (
SFP slot, LC
Optical Fiber (100BaseFX)
Multi mode
0 to 5 km, 1300 nm (50/125
μm
, 800 MHz*km)
0 to 4 km, 1300 nm (62.5/125
μm, 500
Single mode
0 to 40 km, 1310 nm (9/125
μm, 3.5
Multi mode: -20 dBm; Single mode: -5 dbm
Multi mode: -10 dBm; Single mode: 0 dbm
-36 to -32 dBm (Single), -34 to -30 dBm (Multi)
Low Voltage: 24/48 VDC (9 to 60 V)
High Voltage: 110/250 VDC (88 to
300 V)
and 100/240 VAC (85 to 264 V)
Max. 0.68A @ 24 VDC
Max. 0.
35A @ 48 VDC
Max. 0.17/0.11A @ 110/220 VDC
Max. 0.33/0.23A @ 110/220 VAC
Overload Current
Protection
.3 A
Reverse Polarity
Protection
IP 30 protection, metal case
440 x 44 x 254 mm (17.32 x 1.73 x 10.00 in.)
-40 to 75°C (-40 to 167°F) for -T models
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
ABS/BV/CCS/DNV/GL/KR/LR/NKK/PR/RINA
(Pending)
FCC Part 15, CISPR (EN55022) class A
EN50155 (EN/IEC 61373, Category 1, Class B)