manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. multicomp pro
  6. •
  7. Test Equipment
  8. •
  9. multicomp pro MP780050 User manual

multicomp pro MP780050 User manual

1
Mini AC Current Leakage Tester
Model No. MP780050
2 3
Read all instructions before using the appliance and retain for future reference.
• Please follow all safety operation instructions.
• Check the jaws and case insulation before using. If you nd any breakage
or abnormality, or you consider the device is broken, stop using the device
immediately.
• Never operate the meter with the battery cover open.
• Set the function switch to the correct setting before connecting the meter to the
current source to be tested.
• Never apply voltage greater than the specied maximum allowed.
• Use caution with voltages above 25VAC rms as a shock hazard may exist.
• Do not use the product for any purpose other than that for which it is designed.
• Turn the tester off when not in use to save the battery.
• Remove the battery if the tester is not to be used for long periods.
• Replace the battery as soon as the low battery warning appears to avoid possible
electric shock or personal injury caused by incorrect readings.
PRODUCT OVERVIEW
WHAT’S INCLUDED
• AC Leakage Tester
• Batteries.
• Instruction manual.
IMPORTANT SAFETY INFORMATION
OPERATION
CLEANING
• Clean the tester with a clean, soft cloth.
• Do not use any chemicals, abrasives or solvents that could damage the tester.
MAINTENANCE
• When the low battery symbol appears on the LCD the batteries must be replaced.
• Power the tester down and remove the rear battery compartment screw.
• Lift off the battery compartment cover and replace the two AAA(1.5V) batteries
taking note of the polarity.
• Replace the compartment cover and secure the screw.
1 2 3 4
5 6
AC Current Measurement
• Set the Function switch to the desired current range.
• Press the jaw trigger to open the clamp jaws and clamp around the conductor
ensuring it is centred within the clamp jaws.
• The measured value is displayed on the LCD screen.
Data HOLD
• To freeze the current reading on the LCD, press the “HOLD” key.
• HOLD will display on the LCD while the meter is in the Data Hold mode.
• To return to normal function and operation, press the “HOLD” key again.
Backlight function
• Press and hold the “HOLD” key for more than 2 seconds to turn on the LCD
backlight.
• This will also activate the Data Hold function.
• To release the Data Hold function and return the tester to normal operation, press
the “HOLD” key momentarily. To turn off the backlight, press and hold the “HOLD”
key for more than 2 seconds.
LEAKAGE CURRENT TESTER
MAX
HOLD
2A
1. Current sense jaws
2. Rotary function switch
3. Data HOLD and backlight button
4. LCD display
5. Clamp trigger
6. MAX button
LEAKAGE CURRENT TESTER
MAX
2A
HOLD
MAX
LEAKAGE CURRENT TESTER
2A
HOLD
Leakage Current Measurement Load Current Measurement
Leakage into Ground
Conductor
4
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL &
ELECTRONIC EQUIPMENT.
These symbols indicate that separate collection of Waste Electrical and Electronic Equipment
(WEEE) or waste batteries is required. Do not dispose of these items with general household
waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries
can be returned to any waste battery recycling point which are provided by most battery retailers.
Contact your local authority for details of the battery and WEEE recycling schemes available in
your area. Made in China. LS12 2EN
Man Rev 1.0
SPECIFICATIONS
Display 31/2 Digit (1999 count) LCD display
Resolution 100µAAC
Batteries Two AAA 1.5V batteries
Jaw Opening 30mm (1.2”)
Auto Power Off 15 minutes approx
Operating Conditions
0ºC to 30ºC (32ºF to 86ºF) 90% Relative Humidity
30ºC to 40ºC (86ºF to 104ºF) 75% Relative Humidity
40ºC to 50ºC (104ºF to 122ºF) 45% Relative Humidity
Storage Conditions -25ºC to 60ºC (-14ºF to 140ºF) < 90% Relative Humidity
Altitude <3000 meters
Dimensions (H x W x D) 182 x 61 x 34mm
Safety Compliance CAT II 600V
Function Range Resolution Accuracy
AC Current
(60Hz)
200mA 100μA ±(5.0% of reading + 8 digits)
2A 1mA ±(5.0% of reading + 10 digits)
200A 100mA ±(2.5% of reading + 10 digits)

Other multicomp pro Test Equipment manuals

multicomp pro MP720780 User manual

multicomp pro

multicomp pro MP720780 User manual

multicomp pro MP720009 User manual

multicomp pro

multicomp pro MP720009 User manual

multicomp pro MP720025 User manual

multicomp pro

multicomp pro MP720025 User manual

multicomp pro MP780426 User manual

multicomp pro

multicomp pro MP780426 User manual

multicomp pro MP72016 User manual

multicomp pro

multicomp pro MP72016 User manual

multicomp pro MP700005 User manual

multicomp pro

multicomp pro MP700005 User manual

multicomp pro MP720774 User manual

multicomp pro

multicomp pro MP720774 User manual

multicomp pro MP780833 User manual

multicomp pro

multicomp pro MP780833 User manual

multicomp pro MP780053 User manual

multicomp pro

multicomp pro MP780053 User manual

multicomp pro MP720012 User manual

multicomp pro

multicomp pro MP720012 User manual

multicomp pro MP720854 User manual

multicomp pro

multicomp pro MP720854 User manual

multicomp pro MP720105 User manual

multicomp pro

multicomp pro MP720105 User manual

multicomp pro MP760855 User manual

multicomp pro

multicomp pro MP760855 User manual

multicomp pro MP720856 User manual

multicomp pro

multicomp pro MP720856 User manual

multicomp pro MP700110 User manual

multicomp pro

multicomp pro MP700110 User manual

multicomp pro MP780834 User manual

multicomp pro

multicomp pro MP780834 User manual

multicomp pro MP720644 User manual

multicomp pro

multicomp pro MP720644 User manual

multicomp pro MP720645 User manual

multicomp pro

multicomp pro MP720645 User manual

multicomp pro MP720024 User manual

multicomp pro

multicomp pro MP720024 User manual

multicomp pro MP700499 User manual

multicomp pro

multicomp pro MP700499 User manual

multicomp pro MP780052 User manual

multicomp pro

multicomp pro MP780052 User manual

multicomp pro HDS-N Series User manual

multicomp pro

multicomp pro HDS-N Series User manual

multicomp pro MP740890 User manual

multicomp pro

multicomp pro MP740890 User manual

multicomp pro MP780051 User manual

multicomp pro

multicomp pro MP780051 User manual

Popular Test Equipment manuals by other brands

Apera Instruments PH20 user manual

Apera Instruments

Apera Instruments PH20 user manual

Tektronix MTS400 Series Quick start user manual

Tektronix

Tektronix MTS400 Series Quick start user manual

Multi 210 instruction manual

Multi

Multi 210 instruction manual

Hioki BT5525 Startup guide

Hioki

Hioki BT5525 Startup guide

Kett LE-373 operating manual

Kett

Kett LE-373 operating manual

Hanna Instruments HI 98127 user manual

Hanna Instruments

Hanna Instruments HI 98127 user manual

ATS 540 Series instruction manual

ATS

ATS 540 Series instruction manual

Sealey CT955.V2 instructions

Sealey

Sealey CT955.V2 instructions

Valhalla Scientific 4314KVM Operation manual

Valhalla Scientific

Valhalla Scientific 4314KVM Operation manual

LiveWire Innovation Fault Trapper LW-FT100 user manual

LiveWire Innovation

LiveWire Innovation Fault Trapper LW-FT100 user manual

BACtrack b70 owner's manual

BACtrack

BACtrack b70 owner's manual

Fluke 1507 quick start guide

Fluke

Fluke 1507 quick start guide

Fluke 721 Quick reference guide

Fluke

Fluke 721 Quick reference guide

Fluke 4322 Operator's manual

Fluke

Fluke 4322 Operator's manual

Hillstone HAC240 operating manual

Hillstone

Hillstone HAC240 operating manual

Atlantic HVP-50 instruction manual

Atlantic

Atlantic HVP-50 instruction manual

Kusam-meco KM-CAL-905 user manual

Kusam-meco

Kusam-meco KM-CAL-905 user manual

Associated Equipment 6054 Instructions for use

Associated Equipment

Associated Equipment 6054 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.