MULTISPAN LC-2046 User manual

LC-2046
AUXILIARY SUPPLY:
LENGTH COUNTER
Supply voltage
Power consumption
(VA RATING) Approx 4 VA @ 230V AC MAX
ENVIRONMENT CONDITION:
Relative Humidity
Protection Level
(AS Per Request)
Operating Temp. 0°C to 55°C
UP to 95% RH
(non-condensing)
IP-65 (Front side) As per IS/IEC
60529 : 2001
230V AC, 50Hz
MECHANICAL INSTALLATION GUIDELINES
1. Prepare the panel cutout with proper dimensions as shown
above.
2. Fit the unit into the panel with the help of clamp given.
3. The equipment in its installed state must not come in close
proximity to any heating source, caustic vapors, oils steam,
or other unwanted process byproducts.
4. Use the specified size of crimp terminal (M3.5 screws) to
wire the terminal block. Tightening the screws on the
terminal block using the tightening torque of the range of
1.2 N.m.
5. Do not connect anything to unused terminals.
INSTALLATION GUIDELINES
1. This equipment, being built-in-type, normally becomes a
part of main control panel and in such case the terminals
do not remain accessible to the end user after installation
and internal wiring.
2. Do not allow pieces of metal, wire clippings, or fine metallic
fillings from installation to enter the product or else it may
lead to a safety hazard that may in turn endanger life or
cause electrical shock to the operator.
3. Circuit breaker or mains switch must be installed between
power source and supply terminal to facilitate power ‘ON’ or
‘OFF’ function. However this mains switch or circuit breaker
must be installed at convenient place normally accessible to
the operator.
4. Use and store the instrument within the specified ambient
temperature and humidity ranges as mentioned in this
manual.
Page -1
MAINTENANCE
1. The equipment should be cleaned regularly to avoid
blockage of ventilating parts.
2. Clean the equipment with a clean soft cloth. Do not use
isopropyl alcohol or any other cleaning agent.
3. Fusible resistor must not be replaced by operator.
Read complete instructions prior to installation
and operation of the unit.
WARNING : Risk of electric shock.
SAFETY PRECAUTION
!
All safety related codifications, symbols and instructions
that appear in this operating manual or on the equipment
must be strictly followed to ensure the safety of the operating
personnel as well as the instrument.
If all the equipment is not handled in a manner specified
by the manufacturer, it might impair the protection provided
by the equipment.
WARNING GUIDELINES
WARNING : Risk of electric shock.
1. To prevent the risk of electric shock, power supply to the
equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is
being supplied.
2. To reduce electro magnetic interference, use wire with
adequate rating and twists of the same of equal size shall
be made with shortest connection.
3. Cable used for connection to power source, must have a
cross section of 1mm or greater. These wires should have
insulations capacity made of at least 1.5kV.
4. A better anti-noise effect can be expected by using
standard power supply cable for the instrument.
Input (Start Pulse)
Display
Memory
Size
Keys
Counting Direction
Panel Cutout
Upper: 6 digit, 7 segment, 0.40” Red
Nonvolatile
Lower: 4 digit, 7 segment, 0.40” Green
72 (H) x 72 (W) x 60 (D) mm
SET/ENT, SHIFT, INC, RESET
68 (H) x 68 (W) mm
TECHNICAL SPECIFICATION
GENERAL SPECIFICATION:
DISPLAY AND KEYS:
DIMENSION:
MECHANICAL INSTALLATION
TERMINAL CONNECTION
1 - Total Length in meter
2 - Length Counting Speed (Meter/Min)
3 - Relay Status
FRONT PANEL DESCRIPTION
KEY OPERATION
To enter in parameter setting
mode
To reset total Length
To view batch count
PRESS KEYFUNCTION
OPERATOR MODE
PARAMETER SETTING MODE
Edited parameter value to be set,
And move to the next parameter
It will select the digit to modify,
When value is edited
It will change the Value of
selected digit
NPN/PNP Proximity
Micro Switch
UP/ DOWN
Reset Option Front Panel Reset
Terminal Reset
Outline Dimension (mm) Panel Cutout
Dimension (mm)
Press Key
RESET
INPUT SPECIFICATION:
OUTPUT SPECIFICATION:
Relay
Relay Type
Rating
1 nos.
1 C/O (NO-C-NC)
5A, 230V AC
Relay Output
R
01 2 3 4.5
01 2 3
1
2
3
To view grand total
PROXY COLERS CODE
+12V OUTPUT GND
Brown Black Blue
Red Green Black
KEY OPERATION
72
60
68
68
3
72
SET
ENT
RESET
R
LC 2046
MTR/MIN
1 2 3 4 5.6
1 2 3.4
230V AC
50Hz,4VA
NC
I/P
NPN
+12V
I/P
PNP
GND
NO
C
L
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
!
RESET
Made in India
www.multispanindia.com
Page 2
Specifications are subject to change, since development is a continuous process,
So for more updated operating information and Support,
Please contact our Helpline: 9978991474/76/82 or
Email at Ver:2001013[email protected]
PARAMETER SETTING
1 2 3 4 5. 6
9 9 9 9 9. 9
9 9 9 9. 9 9
D O W N
9 9 . 9
9 9 9 9 9 9
m e d I u m
9 9 9 9
1 2 3. 4
s e t
d I a
C O N T
t I m e
D P
p u L S
P P R
Change by
& Key
Change by
& Key
Change by
& Key
Change by
Key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
SET
ENT
SET
ENT
SET
ENT
SET
ENT
SET
ENT
SET
ENT
SET
ENT
Total Length in Mtr.
Speed in Mtr/Min
Set Length Value
Set Diameter Value
Set Count Direction
(UP & Down)
Set Time Value
Set Decimal Point
Set Speed Selection
Set PPR Selection
Press key for save & exit
SET
ENT
NOTE
1). The proximity switch give pulse to counter everytime the
metal on the roller is sensed.
2). Length of Material ( in meter ) for one revolution
= 3.14 X Diameter (mm)
3). Total length
= { 3.14 X Diameter (mm) X Number of Revolutions } / 1000
4). Total Meters/Minute
= { 3.14 X Diameter (mm) X RPM } / 1000 X PPR
WORKING
1). When proxy pulse comes, upper display indicates increment
in ‘Total Length’ in Meter, Lower Display indicates‘Speed’
in Meter/Min according to Diameter and PPR set.
2). For Manual Reset Mode, Set time = 00.0 sec &
For Auto Reset Mode, Set time = 00.1 to 99.9 sec.
3). When Total Length = Set Length, Then Relay will energies ,
and remains ON till Set Auto Reset Time. Relay will turn off
after completion of time.
If time is set = 00.0 sec. then relay remains ON until key
is pressed.
4). If there is a power failure, the last reading is stored in the
memory and Counter starts resume counting from the last
stored value, when power ON.
5). No. of bolts inserted in a roller should be the same as that
of PPR.
Dia mm
20mm Minimum
4mm Distance
Proximity
Note:
PROXY ALIGEMENT
1). Please consult support engineers for sensing area size for
proxy to sense.
2). Please ensure proper sensing area size before installing
proxy sensor in your equipment.
3). Sensing area must be equal or more than the proxy
head size.
NOTE
Slow ( Max. RPM 500)
Medium ( Max. RPM 5000)
Fast ( Max. RPM 15000)
Change by
Key
Change by
Key
Change by
Key
Range :- 000.001
to 99999 mtr
Range :- 00.0
to 99.9 sec
Range :- 0000.01
to 9999.99 mm
Range :-
999.999,
9999.99, 99999.9
& 999999
Pulse per revolution

Other MULTISPAN Cash Counter manuals

MULTISPAN LC-2046 User manual

MULTISPAN

MULTISPAN LC-2046 User manual

MULTISPAN PC-1044 User manual

MULTISPAN

MULTISPAN PC-1044 User manual

MULTISPAN PC-444 User manual

MULTISPAN

MULTISPAN PC-444 User manual

MULTISPAN PC-1006D User manual

MULTISPAN

MULTISPAN PC-1006D User manual

MULTISPAN PC-2044 User manual

MULTISPAN

MULTISPAN PC-2044 User manual

MULTISPAN MMC-1046RD User manual

MULTISPAN

MULTISPAN MMC-1046RD User manual

MULTISPAN TWS - 1400F User manual

MULTISPAN

MULTISPAN TWS - 1400F User manual

MULTISPAN LC-1046D User manual

MULTISPAN

MULTISPAN LC-1046D User manual

MULTISPAN PIC-9004 User manual

MULTISPAN

MULTISPAN PIC-9004 User manual

MULTISPAN LC 1046D User manual

MULTISPAN

MULTISPAN LC 1046D User manual

MULTISPAN BC-1046D User manual

MULTISPAN

MULTISPAN BC-1046D User manual

Popular Cash Counter manuals by other brands

Kübler 717 Series operating instructions

Kübler

Kübler 717 Series operating instructions

Yoosol Electronics PRIMO-P2 Operation manual

Yoosol Electronics

Yoosol Electronics PRIMO-P2 Operation manual

Banner TCER Setup guide

Banner

Banner TCER Setup guide

Polar Electro GD882 instruction manual

Polar Electro

Polar Electro GD882 instruction manual

IQAir ParticleScan CR user manual

IQAir

IQAir ParticleScan CR user manual

Lionel BANJO SIGNAL Installation and operating instructions

Lionel

Lionel BANJO SIGNAL Installation and operating instructions

Tektronix VX4101 user manual

Tektronix

Tektronix VX4101 user manual

MZ electronic EV-040 Instructions for use

MZ electronic

MZ electronic EV-040 Instructions for use

Hengstler Signo 721 quick start guide

Hengstler

Hengstler Signo 721 quick start guide

ChemoMetec NucleoCounter NC-200 quick guide

ChemoMetec

ChemoMetec NucleoCounter NC-200 quick guide

Cashscan MSB-30 instruction manual

Cashscan

Cashscan MSB-30 instruction manual

Nautilus Hyosung MX5600 installation manual

Nautilus Hyosung

Nautilus Hyosung MX5600 installation manual

Kübler CODIX 540 operating instructions

Kübler

Kübler CODIX 540 operating instructions

DIEBOLD NIXDORF DN 400 Series Operator's manual

DIEBOLD NIXDORF

DIEBOLD NIXDORF DN 400 Series Operator's manual

red lion LNXC1 quick start guide

red lion

red lion LNXC1 quick start guide

red lion CUB 1 manual

red lion

red lion CUB 1 manual

Lenord, Bauer GEL 104 user manual

Lenord, Bauer

Lenord, Bauer GEL 104 user manual

B+K precision 1804D instruction manual

B+K precision

B+K precision 1804D instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.