My Fireplace Blower GFK-160A User manual

Installation Videos:
MY
FireplaceBlower MyFireplaceBlower.com:
Installation Instructions:
Installer is responsible to check local codes
and read all instructions prior to installation.
Layout designed in U.S.A. © 2014
My Fireplace Blower
Burlington, Wisconsin
1-800-466-4045
Drywall dust or other fragments may be present in your replace’s vent space, clean this area before you install the
blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy.
Instructions for Design Version - GFK-160A Blower Kit with Cord Set
This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re-
sponsibility to read all instructions and consult the Owner’s Installation Manual for your particular model number
for Supplemental Information before starting installation. Blower operates on 120V/60Hz power.
CLICK
High Quality Aftermarket Fireplace Blowers & Fans 1-800-466-4045
Check the contents of the carton.
Make sure nothing was damaged in shipment.
Do NOT install a damaged blower kit!
Blower Kit Parts
Step 1: Turn Off Fireplace and allow it to
cool down. Disconnect from 120V Power. Shut
off the Gas supply. Remove the louver which
covers the lower vent space below the rebox.
Lay cord set out in a straight line, with the
3-Prong Power Plug furthest away from the
replace. Figure: 1
Step 2: Connect black and white wires of power cord
to either metal spade attached to motor; push discon-
nects onto the metal tabs. Use small screw to ground
ring terminal to small hole on end of fan. (Figure: 1)
CLICK
CLICK
NOTE: Diagrams and Illustrations NOT to Scale
Page 1 of 5
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK!
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER!
When installed, make sure to contain any excess wire of the cord set;
Preventing it from making contact with moving or hot objects.
Description Qty.
Blower - Magnetic Mount
Thermodisc / Heat Sensor
Variable Speed Control
Power Cord
3-Prong to 2-Prong Adapter
Installation Instructions (Downloadable)
1
1
1
1
1
1
1
Jumper Wire (Black)
Small Ground Screw 1
Position blower with rectangle air exit ports facing up
and motor facing left. Slide blower into lower vent
space centered against the rear wall.(Figures: 1,3&16)
For “SL” Series, see (Figures: 5&14); a removable
cross-member bar may be present.
•Does not matter which metal tab you
connect the black and white wires to.

Step 2: With the magnetic Thermodisc and
Variable Speed control connected together,
place the thermodisc to the underside of the
rebox. Typically, there is a screw stud right
of center on the underside of the rebox or
on the lower right side of the rebox, place
next to screw stud or in this area on under-
side of rebox. (Figure: 3,4,5 & 15)
The silver disc of the Thermodisc must be
touching metal side of the rebox to sense
heat. The magnets will simply hold itself to
the metal.
Step 3: The Varibale Speed Control may
be mounted on the right side of the lower
vent space (Figure: 6) or on the front of the
center control panel (Figure: 5).
Wipe off the mounting location to ensure it
is clean. Remove the clear backing of velcro
attached to Variable Speed Control and
apply to the mounting location.
Turn the dial to the left and it will click off,
turn right to reduce speed.
CLICK
Figure: 3
Installer is responsible to check local codes
and read all instructions prior to installation.
Layout designed in U.S.A. © 2014
NOTE: Diagrams and Illustrations NOT to Scale
Page 2 of 5
My Fireplace Blower
Burlington, Wisconsin
1-800-466-4045
MyFireplaceBlower.com:
FIREBOX AREA
1/8”TO 1/4 DISTANCE
FIREPLACE BACK WALL
BLOWER
THERMODISC / HEAT SENSOR
PLACEMENT
Figure: 4
VARIABLE
SPEED CONTROL
THERMODISC /
HEAT SENSOR
(SL) SERIES
CROSS-MEMBER
BAR NOTCH
Figure: 5
You may want to wait and run blower a few times to see where you would like to mount the variable
speed control. The speed control must be in the ON position in order for the blower to run. The blower
will not turn on until the Thermodisc reaches approximately 120 degrees and the variable speed control
is in the ON position.
Figure: 2
Pull blower forward 1/8” to 1/4” from back wall of
replace. (Figure: 2)
Multi-Sided replace see Figure: 13.

Step 4: Check Junction Box style (Figure: 7,8 &12) and
follow the instructions for your type.
Power Strip style: Insert the white wire from the Variable
Speed Control and the loose black wire from the Thermdisc
into of the two small ports in the lower corner of Junction
Box. Below where ‘FAN’ is printed, one port is above the
other. Insert the fan Plug where “FAN” is printed on the
Junction Box. (Figure: 6&7)
CLICK
Installer is responsible to check local codes
and read all instructions prior to installation.
Layout designed in U.S.A. © 2014
NOTE: Diagrams and Illustrations NOT to Scale
Page 3 of 5
My Fireplace Blower
Burlington, Wisconsin
1-800-466-4045
MyFireplaceBlower.com:
Figure: 6
Figure: 9
Power Strip style Junction Box
Metal Style
Junction Box
Figure: 10
Metal Style: Connect one end of Jumper wire to white wire
of Variable Speed Control and other end of Jumper wire to
black wire (female disconnect) from Junction Box. Connect
black wire of Thermodisc to the other black wire from Junc-
tion Box. Push disconnects together, one ts inside the oth-
er. (Figure 8,9 & 10.) Use 3-Prong to 2-Prong plug adapter
and insert fan plug into receptacle labeled “FAN”.
Metal style Junction Box
FAN
REM/AUX
TRANS
NEUTRAL
HOT
VARIABLE SPEED CONTROL
THERMODISC /
HEAT SENSOR
JUNCTION BOX
BLACK
WHITE
BLACK
Figure: 7
Figure: 8
FAN
JUNCTION BOX
VARIABLE SPEED CONTROL
THERMODISC
(HEAT SENSOR)
WHT
GRN
BLACK
BLK
110-120 VAC
BLOWER
POWER SUPPLY
BLK
BLK
BLK
WHT
GROUND
WHT
BLK
BLACK
JUMPER
BLACK
BLACK WHITE
WHITE
THERMODISC
(HEAT SENSOR)
VARIABLE SPEED CONTROL
(RHEOSTAT)
JUNCTION BOX
WHITE
WHITE
BLACK
BLACK
BLACK
BLACK JUMP WIRE

CLICK
Installer is responsible to check local codes
and read all instructions prior to installation.
Layout designed in U.S.A. © 2014
NOTE: Diagrams and Illustrations NOT to Scale
Page 4 of 5
My Fireplace Blower
Burlington, Wisconsin
1-800-466-4045
MyFireplaceBlower.com:
Power Cord Style: Connect white wire
of variable speed control to one end of
Jumper Wire and other end of jumper
wire to female disconnect (Black Wire)
on power cord. (Figures: 11&12)
The black wire of variable speed control
is connected to black wire of Thermodisc.
Connect other black wire of thermodisc
to male disconnect (Black Wire) on pow-
er cord. (Figures: 11&12)
Plug fan power cord into the power re-
ceptacle.
POWER CORD STYLE WIRING
BLACK
THERMODISC /
HEAT SENSOR
VARIABLE SPEED CONTROL
BLOWER
RECEPTACLE
PLUG INTO 120V
EXISTING OUTLET
AUX / REMOTE
RECEPTACLE
BLACK
BLACK
POWER
BLACK
JUMPER WIRE
BLACK
WHITE WHITE
BLACK
POWER CORD STYLE JUNCTION BOX
BLOWER
VARIABLE
SPEED CONTROL
THERMODISC /
HEAT SENSOR
Black
WHITE
Black
Black
BLACK
BLACK
BLACK
Figure: 11
Figure: 12
THERMODISC
HEAT SENSOR
VARIABLE
SPEED CONTROL
Figure: 15
Figure: 16

MY
FireplaceBlower
NOTE: Diagrams and Illustrations NOT to Scale
Page 5 of 5
Installations in Canada must conform to the current CAN/CGAB-419.1 and .2 Gas Installation Code and local regula-
tions. When installing the blower fan kit, it must be electrically grounded in accordance with CSA C22.1 Canadian
Electrical Code Part 1 and/or Local Codes.
Installations in the USA must conform to local codes, or in absence of local codes or the National Fuel Gas Code,
ANSI Z223.1-1988. When installing the blower fan kit, it must be grounded in accordance with local codes, or in
absence of local codes, with the National Electrical Code, ANSI/NFPA 70-1987.
My Fireplace Blower LLC produces and sells aftermarket replace blower kits; which require consultation
of an Owner’s Installation Manual from the Manufacturer of a particular replace model number for in-
stallation. During Installation of a replace blower kit or replacement blower, refer to the Owner’s Instal-
lation Manual for your particular replace model to obtain supplemental information. My Fireplace Blower
LLC is not responsible for any damage incurred during installation or resulting from installation of a re-
place blower kit, which was directed and/or conducted from the information within this document.
Installation Videos:
Installation Instructions:
Figure: 13
CLICK
CLICK
CLICK
Finishing Steps:
If appliance is connected to a gas supply, turn it
back on.
If Appliance is connected to 120 Volt Power, turn
it back on.
Installer is responsible to check local codes
and read all instructions prior to installation.
Layout designed in U.S.A. © 2014
My Fireplace Blower
Burlington, Wisconsin
1-800-466-4045
MyFireplaceBlower.com:
(SL) SERIES
CROSS-MEMBER BAR
Figure: 14
The fan will not run until the Thermodisc / Heat Sensor reaches approximately 120°F
and the Variable Speed Control is turn to the “ON” Position! This means the Heat
Sensor must be in contact with a hot spot on the underside of the Firebox.
FAN
For multi-sided replaces,
the blower is positioned on
a side under the vent space.
This is an example for ST & PIER models.
Table of contents
Other My Fireplace Blower Fireplace Accessories manuals
Popular Fireplace Accessories manuals by other brands

Heat & Glo
Heat & Glo DRIFTWOOD-C32 installation instructions

GHP Group
GHP Group Pleasant Hearth FN-5701 owner's manual

Hearth & Home
Hearth & Home LOGS-NDI35 Log Placement Instructions

FireplaceXtrordinair
FireplaceXtrordinair CoolSmart TV manual

Enviro
Enviro C34 instruction manual

Valor
Valor H3 Series installation manual

New Buck Corporation
New Buck Corporation 80ZC user manual

Napoleon
Napoleon CONTINENTAL W175-0159 instructions

FireplaceXtrordinair
FireplaceXtrordinair 564 FPX quick guide

Firegear
Firegear ADP10-OUT installation instructions

Blue Sky Outdoor Living
Blue Sky Outdoor Living TT22SQ owner's manual

Napoleon
Napoleon ROGUE SE625-1 Quick assembly guide