PRODUCT MANUAL ISENSOR TABLETOP -DT.MP.IM.22.01.2
Gas injection is compatible with the multi-cycle mode, although keep in mind that the gas
will only be injected in the last repetition, as with sealing.
5.5.3. Autoclean
When the vacuum pump’s oil has taken on a whitish shade, due to water condensation, it
can be removed using this mode. Due to the temperature, this process means any water
that may be in the oil will end up evaporating and exiting the pump.
These water particles may cause rust particles to develop on internal components of the
pump.
➔The vacuum packer will notify the user of the need to perform a self-cleaning process
after every 200 cycles. This will happen when the appliance is connected to the
electricity grid, or it is turned on from the “OFF” rest mode. If the lid is lowered during
this time, the “AUTOCLEAN OIL” process will begin automatically.
➔If you do not wish to perform the AUTOCLEAN process when the notification
appears, you can press the direction buttons (right and left) to go through the menu
as normal and perform the cycle you prefer.
You can run an AUTOCLEAN cycle whenever you wish by manually entering AUTOCLEAN
mode from the operating mode selection menu. The maximum duration of AUTO-CLEAN
mode is 20 minutes, although you can stop it by pressing the centre button.
5.6.Packaging
To pack a product, the bag (appropriate for vacuum packing) must be placed correctly on
the polyethylene bar with the entire width of the bag above the sealing area. Make sure that
there is no product on the sealing bar. Then, lower the lid of the vacuum packer. It is
important to remember that a packing process cannot begin while you are configuring the
manual mode parameters.
NOTE: We recommend using the safety latch during each vacuum packing cycle.
At this stage, the active mode or program will start up and the indicators of the processes
to be carried out will light up continuously (vacuum, extra vacuum, gas injection, sealing,
progressive air entry, repetitions):
-The vacuum process (VACUUM) extracts the air from the chamber and the central
display shows the vacuum percentage up to that moment.
-The extra vacuum procedure (EXTRA VACUUM) keeps the vacuum pump working
for the number of seconds programmed. This extracts the air from very porous
foods. The central display shows the number of seconds passed.
-Gas injection (GAS) fills the chamber with the gas percentage specified in the
program. The percentage of gas inserted is also shown on the central display.
-Sealing consists of three phases. The first is the lifting of the cylinders. During this
phase, the central display shows the set sealing time in seconds. The second is the
heating of the heating element. At this stage the SEAL display will progressively
decrease from the previous value. The third stage, with a duration of five seconds, is