mychway SR-MJ3201 User manual

User Manual
SR-MJ3201

Preface
Dear users:
We’re pleased to present to you the 3 In 1 Microcurrent Skin
Rejuvenation Magic Gloves Beauty Facial Machine that’s
featuring in deep hydration, deep cleaning, skin firming and
rejuvenation. It is a multifunctional beauty machine, targeted at
various skin problems such as dehydrated and malnourished skin,
clogged pores, skin laxity and so on. Microcurrent gloves and
rollers are specialized skin care machine for professional use,
which needs to be handled by professionals with proper training.
Any improper use will result in adverse consequences. Therefore
we advise any personnel read this guide thoroughly and follow
the instructions strictly before operation.
We believe our quality product will bring in good returns on your
end. Also, you can count on our worry-free after-sales service.
Thank you!

Table of Contents
Preface
Part I
Brief Introduction
Advantages
Working Principles & Treatments
Cleaning & Hydrating
Skin Firming
Eye Care
Tightening & Skin Rejuvenation
Part II
1. Detailed Operations
2. Safety Precautions
3. Dos and Don’ts
4. Troubleshooting & Solutions
5.FAQs
6. Packing List
7. Operational Diagrams

Part I
Brief Introduction
Microcurrent gloves and microcurrent rollers are currently the most popular beauty
machines that work on deep cleaning, hydrating and anti-aging. It’s an effective
replacement of all the traditional facial and eye care programs in beauty salons.
Moreover, it’s convenient and easy to operate. It solves various skin issues for
beauty-lovers. This equipment requires no injection, no medication, no operation,
thus having no side-effects. It is used externally during the whole process and has an
immediate effect. Ions use direct current polarity to strengthen the penetration of
nutritive active substances into the skin, so as to beautify the skin, and separate the
dust, garbage and excess cutin in the skin for deep cleaning of the skin.
Advantages
1. 3-in-1 beauty machine that works on your overall facial care.
2. Painless, non-invasive during the process. Skipping any recovery periods without
affecting any work and life plans.
3. No consumption, low cost and quick returns.
4. Wider range of treatment and rapid and significant effect.
5. It will not cause any lumpiness, bleeding and swelling and stasis.
6. It uses the interaction between positive and negative ions to produce mutual
attraction and mutual repulsion, achieving beauty results of deep cleaning and leading
in nutrition.
7. Microcurrent gloves can effectively activate cells and increase skin elasticity.
Cleaning & Hydrating
Principles
Face Ion Treatment
Ion+/- nutrition lead-in uses the principle that like charges repel each other; unlike
charges attract so that nutrient active substances of the same polarity can penetrate
deep into the skin through the sweat gland or help strengthen the penetration so as
to achieve the effect of purification of the skin.
ION- : When it’s at ION- mode, it can be used for nutrition lead-in. The customer holds
the ‘+’ passive electrode probe while the probe is at it’s ‘-’ mode so the nutrients
applied on the skin is negatively charged. When the active substances in essential
oil/cream or other skin care products meet the charges of same polarity will attract
and therefore accelerate the process of penetrating through pores, sweat gland, and

eventually fasten the nutrients absorption. In this way, it can achieve it’s skin care
effect.
ION+ : When it’s at ION+ mode, it can be used for waste lead-out. The customer holds
the ‘-’ passive electrode probe so some of the dust, dirt and excess cutin in our skin is
negatively charged. Through the equivalent exchange of ions (positive for positive,
negative for negative), the gunks hidden in our pores can be easily led out, thus
achieving the effect of cleaning. In this way, it can achieve it’s skin cleansing effect.
Effects
1. Deep channel in nutrition and accelerate absorption.
2. Lead out gunks hidden inside pores and dredge pores.
3. Replenish skin with moisture and brighten skin.
4. Refine skin and improve skin texture.
5. Deep cleanse skin and minimize enlarged pores.
Applicable Range
1. Those with dry, dehydrated and malnourished skin.
2. Those with poor skin absorption and lack of moisture at skin base.
3. Those with dull skin and uneven skin tone.
4. Those with clogged pores and thick stratum corneum layer.
5. Those with coarse skin and enlarged pores.
Inapplicable Range
1. Those with severely sensitive skin or those in allergic phase.
2. Those with extensive facial trauma.
3. Those who are pregnant and those suffering from serious heart disease, severe
three H’s(hypertension, hyperlipidemia, hyperglycemia), serious diseases, etc.
4. Those with skin diseases and infectious diseases.
5. Those who have just received injection, such as intradermal injection,
micro-needling, or those with skin cuts.
6. Use with caution for those who are allergic to electric current.
Notes after Operation
1. Strengthen hydration and always use sun protection.
2. Do not use stimulating skin care products including scrub, exfoliating and AHAs
within one week after operation.
3. Avoid staying up late, smoking and drinking, and eat more fruits and vegetables
and less greasy food.
4. Apply a hydrating mask once a day for three days.
5. Do not wash your face with hot water within 3 days after operation. (Use warm

water instead)
Skin Firming
Principles
Microcurrent Gloves
The stimulating current energy sent by the gloves is effectively transmitted to the
human body and stimulates important acupoints of the human body to achieve the
purpose of massage. Microcurrent gloves have a magical effect on skin care. It
activates cells, restores skin elasticity, and slows skin aging and addresses other skin
problems.
Effects
1. Activate cells and increase skin elasticity.
2. Reduce facial fine lines, dry lines and dynamic wrinkles.
3. Improve facial relaxation and softness.
4. Tighten skin, prevent skin aging.
Applicable Range
1. Those with loose and soft skin.
2. Those with fine lines, dry lines and dynamic wrinkles.
3. Those with inelastic skin.
4. Those with coarse skin.
Inapplicable Range
1. Those with severely sensitive skin or those in allergic phase.
2. Those with extensive facial trauma.
3. Those who are pregnant and those suffering from serious heart disease, severe
three H’s(hypertension, hyperlipidemia, hyperglycemia), serious diseases, etc.
4. Those with skin diseases and infectious diseases.
5. Those who have just received injection, such as intradermal injection,
micro-needling, or with skin cuts.
6. Use with caution for those who are allergic to electric current.
Notes after Operation
1. Do not wash your face with hot water within 3 days after operation; (Use warm or
cold water instead).

2. Strengthen hydration and always use sun protection.
3. Apply a hydrating mask once a day for three days.
4. Avoid staying up late, smoking and drinking, and eat more fruits and vegetables
and less greasy food.
5. Avoid ‘3H’ food (food that will cause hypertension, hyperlipidemia, hyperglycemia);
eat less greasy food.
Eye Care
Principles
Eye Ion Treatment
Ion+/- nutrition lead-in uses the principle that like charges repel each other; unlike
charges attract so that nutrient active substances of the same polarity can penetrate
deep into the skin through the sweat gland or help strengthen the penetration so as
to achieve the effect of skin care, fading dark circles, reducing dry lines and fine lines
around the eyes.
ION- : When the active substances in eye serum/cream meet the charges of same
polarity will attract and therefore accelerate the process of penetrating through pores,
sweat gland, and eventually fasten the nutrients absorption.
ION+ : Through the equivalent exchange of ions (positive for positive, negative for
negative), the gunks hidden in our pores can be easily led out, thus achieving the
effect of skin cleaning around the eyes.
Effects
1. Deeply channel in nutrition needed for the eyes.
2. Reduce dark circles, eye edema and eye bags.
3. Fade dry lines, fine lines and slight wrinkles.
4. Relieve eye fatigue and dry eyes.
5. Dredge skin pores around eyes and accelerate absorption.
6. Fade dark skin around eyes.
Applicable Range
1. Those with dehydrated and malnourished skin around eyes.
2. Those with puffy eyes and eye bags.
3. Those with dry lines, fine lines and dynamic wrinkles.
4. Those with eyestrain and dry eyes.
5. Those with poor skin absorption around eyes and dark circles due to staying up late
often.

Inapplicable Range
1. Those with severely sensitive skin or those in allergic phase.
2. Those with extensive facial trauma.
3. Those who are pregnant and those suffering from serious heart disease, severe
three H’s(hypertension, hyperlipidemia, hyperglycemia), serious diseases, etc.
4. Those with skin diseases and infectious diseases.
5. Those who have just received injection, such as intradermal injection,
micro-needling, or with skin cuts.
6. Use with caution for those who are allergic to electric current.
Notes after Operation
1. Avoid drinking, smoking or staying up late.
2. Strengthen hydration and always use sun protection.
3. Apply eye mask at least 3 times a week.
4. It is advised not to use stimulating products, such as alcohol, AHA or scrub.
Tightening & Skin Rejuvenation
Principles
Ion Treatment
Ion+/- nutrition lead-in uses the principle that like charges repel each other; unlike
charges attract so that nutrient active substances of the same polarity can penetrate
deep into the skin through the sweat gland or help strengthen the penetration so as
to achieve the effect of purification of the skin.
ION- : When it’s at ION- mode, it can be used for nutrition lead-in. The customer holds
the ‘+’ passive electrode probe while the probe is at it’s ‘-’ mode so the nutrients
applied on the skin is negatively charged. When the active substances in essential
oil/cream or other skin care products meet the charges of same polarity will attract
and therefore accelerate the process of penetrating through pores, sweat gland, and
eventually fasten the nutrients absorption. In this way, it can achieve it’s skin care
effect.
ION+ : When it’s at ION+ mode, it can be used for waste lead-out. The customer holds
the ‘-’ passive electrode probe so some of the dust, dirt and excess cutin in our skin is
negatively charged. Through the equivalent exchange of ions (positive for positive,
negative for negative), the gunks hidden in our pores can be easily led out, thus
achieving the effect of cleaning. In this way, it can achieve it’s skin cleansing effect.

Microcurrent Gloves
The stimulating current energy sent by the gloves is effectively transmitted to the
human body and stimulates important acupoints of the human body to achieve the
purpose of massage. Microcurrent gloves have a magical effect on skin care. It
activates cells, restores skin elasticity, and slows skin aging and addresses other skin
problems.
Effects
1. Deep channel in nutrition and accelerate absorption.
2. Replenish skin with moisture and brighten skin.
3. Refine skin and improve skin texture.
4. Deep cleanse skin and minimize enlarged pores.
5. Improve facial relaxation and softness.
6. Fade dry lines, fine lines and slight wrinkles.
7. Relieve eye fatigue and dry eyes.
8. Reduce dark circles, eye edema and eye bags.
9. Tighten skin and increase skin elasticity.
10. Prevent skin aging.
Applicable Range
1. Those with dull, lusterless skin and uneven skin tone.
2. Those with loose and sagging skin.
3. Those with coarse skin and enlarged pores.
4. Those who sit in office for long hours, facing UV light.
5. Those with edema and loose skin after child delivery.
6. Those with dehydrated and malnourished skin.
7. Those with dull skin and uneven skin tone.
8. Those with clogged pores and thick stratum corneum layer.
9. Those with dry lines and fine lines around eyes.
10. Those with dry, dehydrated skin and dark circles around eyes due to staying up
late often.
Inapplicable Range
1. Those who have just received injection, such as hyaluronic acid, intradermal
injection, wrinkle removal , or plastic surgery.
2. Those with hypertension, heart disease, diabetes, severe thyroid disease and so
on.
3. Those with severe sensitive skin or those who are allergic to metals or those who’s
suffering from allergy.
4. Those with wounds or cuts.

5. Those in menstruation, pregnancy, lactation and surgery recovery.
6. Those with skin diseases and infectious diseases.
7. Use with caution for those who are allergic to electric current.
Notes after Operation
1. Do not wash your face with hot water within 3 days after operation; (Use warm or
cold water instead).
2. Strengthen hydration and always use sun protection.
3. Apply a hydrating mask once a day for three days.
4. Avoid staying up late, smoking and drinking, and eat more fruits and vegetables
and less greasy food.
5. Avoid ‘3H’ food (food that will cause hypertension, hyperlipidemia, hyperglycemia);
eat less greasy food.
Part II
1. Detailed Operation
After checking that the instrument is connected properly, the following starting
interface will appear when the power supply is turned on.

1.1 Function Selection
Home
Restore
Start/Pause
Energy +/-
1.2 Detailed Operation: Microcurrent Rollers
Select to go to the interface below

Working Time
Time +/-
Energy Display
Energy +/-
ION+/ION- (Have the customer hold the passive
electrode probe at all times when selecting either ION+ or ION- treatment)
1.3 Detailed Operation: Microcurrent Eyes
Select to go to the interface below

Working Time
Time +/-
Energy Display
Energy +/-
ION+/ION- (Have the customer hold the passive
electrode probe at all times when selecting either ION+ or ION- treatment)
1.4 Detailed Operation: Microcurrent Gloves
Select to go to the interface below

Working Time
Time +/-
Energy Display
Energy +/-
Working Mode Display
Select Microcurrent Glove Working Mode
2. Safety Precautions
Please consult your doctor or professionals before using the device if you have the
following symptoms:
1. Those who are pregnant or lactating.
2. Those with heart disease or pacemaker equipped.
3. Those whose wounds have not healed and who are recovering from the operation.
4. Those with epilepsy, severe diabetes and hyperthyroidism
5. Those with malignant tumor, hemophilia or severe bleeding.
6. Those with skin diseases and infectious diseases.
7. Use with caution for those who are allergic to electric current.
3.Dos and Dont’s
1. Use a grounding pin and make sure the power socket of the device is properly
connected before each operation.
2. Ensure that the voltage of the device is appropriate. If the voltage of the local
power supply is unstable, we recommend that users increase to the matching power
voltage.
3. In order to ensure the therapeutic effect and normal service life expectancy of the
device, please use the specified accessories provided or recommended by the original
manufacturer.

4. The device should not be placed in wet environment or near water, nor should
they be directly exposed to sunlight.
5. Do not place the device near a strong heat source, because this may affect the life
and normal use of the device.
6. Before treatment, please remove all metal objects from the body first, so as to
avoid unexpected conditions and influence the curative effect.
7. Please restrain from using the device on eyes, thyroid, parathyroid, testicles,
abdomen of pregnant women, and pacemakers.
8. Patients who are suffering from illness should consult with a doctor and gain
permission from the doctor before using.
9. Please turn off the power switch of the device, and ensure that the total power
supply of the device is turned off before the staff leaves after daily use, so as to
ensure the safety of the electrical products.
10. Use device or train device operators in strict accordance with instructions in the
user manual.
11. Start from the lowest energy level and slowly add up.
12. When using this device, the operating parts must be kept moist and dry skin
should be avoided.
13. Clean the instrument with normal saline after operation to ensure its cleanliness
and hygiene and prolong its service life.
14. Inform the customer what’s expected during the microcurrent rollers and gloves
treatment to avoid startling the customer.
15. Microcurrent rollers and microcurrent gloves can be used alone or together for
better beauty result.
16. Use both hands and make sure the gloves are in full contact with the skin; start
from the lowest energy and slowly add up after adaptation; do not start with high
energy level to avoid discomfort.
17. Have the customer hold the passive electrode probe during the microcurrent
treatment.
4. Troubleshooting & Solutions
1. The instrument cannot be started, but the key light on the back of the instrument
does not work?
A. Make sure the power cord is connected to a valid power socket.
B. Whether the fuse tube on the back of the instrument is loose or burnt out.
2. No microcurrent energy output from the microcurrent roller?
A. Please check whether the plug connecting the instrument handle and the body is
tightly connected.
B. Please check if there’s any other substance on the face.
C. Please check if the customer is holding the passive electrode probe.
D. If the above methods cannot address the issue, please contact the instrument

dealer for assistance.
3. I can start the instrument, but the screen show’s error message?
A. Please unplug the power plug behind the instrument and wait for about 1 minute
before restarting the instrument.
B. If the above methods cannot be handled, please contact the instrument dealer for
assistance.
5.FAQs
1. Q: Is ion treatment harmful to the skin?
A: No. Because ion+/- nutrition lead-in uses the principle that like charges repel each
other; unlike charges attract so that nutrient active substances of the same polarity
can penetrate deep into the skin through the sweat gland or help strengthen the
penetration so as to achieve the effect of purification of the skin. So ion treatment
does not harm the skin. On the contrary, it’s a great approach to skin care.
2. Q: Can I wear makeup after the treatment.
A: Yes. The electric ion causes the chaos cell at the inner layer of facial skin to
rearrange through the positive ion so it precipitates the toxin, removes the skin inner
layer dirt, so the skin can breathe again. It’s non-invasive, no wound, safe, healthy, fast
and effective.
3. Q: Will my skin deteriorate if I stop doing it?
A: No. This only targets at certain skin problems so that it can improve and deeply
clean the skin, which belongs to the maintenance and improving skin of malnutrition
caused by other factors. It helps to absorb nutrients in skin cares products and relieve
sallow, dehydrated, coarse or wrinkled skin. Your skin will only go back to its natural
state if your stopped the treatment.
6. Packing List
1x main machine
1 x holder
1x power supply
1 pair magic gloves
2 x ion +
2 x ion -

7.Operational Diagrams
Parameter
Adjustment
Product
Techniques
Diagrams
Cleaning&Hydrating: 60 min, once/week
Microcurrent
roller energy
level:
20%-80%
Mode:
Lead out: ION+
Lead in:ION-
Makeup
remover+
Cleanser+
Base mask+
Cold&hot
steam+
Exfoliator+
Serum+
Sheet
mask+
SR-MJ3201
1. Remove makeup and clean
face, 5 min.
2. Apply toner, 1 min.
3. Apply cleansing base
mask+hot steam, 10 min.
4. Clean the treatment area,
2 min.
5. Apply a layer pf exfoliator
that is the thickness of a piece
of paper evenly on the face.
6. Have the customer hold
the passive electrode probe.
7. ION+ treatment: lift from
chin to earlobe, mouth corner
to ear gate, nose wing to
temple in parallel lines and
make sure one line is right to
another, 2 min.
8. Lift towards the hairline on
forehead, 1-2 min.
9. Do the same on the other
side.
10. Clean the treatment area,
2 min.
11. Apply (hydrating) essence
evenly all over the face, 1 min.
12. ION- treatment: start
from chin and move the
probe in circular motions to
lift the the treatment area in
lines with one line next to
Technique7
Technique8
Technique12

another, 3 times.
13. Move the probe in small
circles towards the hairline,
1-2 min.
14. Do the same on the other
side.
15. Remove the passive
electrode probe from the
customer.
16. Apply sheet mask, 15
min.
17. Remove the mask and
clean.
18. Apply toner, serum,
cream and sunscreen.
Recommended treatment:
10 treatments account for one full course. After one treatment, skin is thoroughly
cleaned and fully hydrated. After a full course, skin becomes more hydrated and elastic.
It can also lock in moisture better. After three courses, skin appears to be hydrated,
fine, elastic and can lock in moisture for 24 hours.
Skin Firming: 60 min, once/week
Microcurrent
gloves energy
level:
20%-80%
Makeup
remover+
Cleanser+
Base mask+
Hot&hot
steam+
Massage
cream+
Serum+
Sheet
mask+
SR-MJ3201
1. Remove makeup and clean
face, 5 min.
2. Apply toner, 1 min.
3. Apply cleansing base
mask+hot steam, 10 min.
4. Clean the treatment area,
2 min.
5. Massage face and apply
massage cream on face evenly
and caress the treatment
area, 3 times.
6. Press on the following
acupoints: Saliva
Container(Ren-24), Earth
Granary(ST-4), Great
Welcome(ST-5), Jaw
Bone(ST-6), Below the
Joint(ST-7), Welcome
Fragrance(LI-20), Cheek Bone
Crevice(SI-18), Temples(EM5),
Technique6
Technique11
Technique12,18

Bright Eyes(BI-1), Gathered
Bamboo(BI-2), Yuyao(EM3),
Silken Bamboo Hollow(TE-23),
Pupil Crevice(GB-1), Container
of Tears(ST-1), Four
Whites(ST-2), 3 times.
7. Caress the whole face, 3
times.
8. Lift the treatment area
with both hands as if plucking
the string, 1 min.
9. Alternate hands in lifting
the treatment area on one
side as if plucking the string, 1
min.
10. Do the same on the other
side.
11. Alternate hands in lifting
in three lines, tracing from
chin to earlobe, mouth corner
to ear gate, nose wing to
temple on one side of the
face, 3 times.
12. Lift towards hairline on
forehead, 3 times.
13. Do the same on the other
side.
14. Brace skin with middle
and ring fingers on forehead
as if writing ‘Z’, slide to the
ear back and force 3 times
and finish behind ear, 1 min.
15. Clean the treatment area.
16. Apply (anti-aging)
essence evenly all over the
face, 1 min.
17. Microcurrent gloves
operation: Lift upwards on the
neck in parallel lines with one
line next to another, 3 times.
18. Lift towards hairline on
forehead, 3 times.
19. Apply sheet mask, 15
min.
Technique14

20. Remove the mask and
clean,1 min.
21. Apply toner, essence,
cream and sunscreen.
Recommended treatment:
10 treatments account for one full course. Once done, skin is lifted and tightened. After
a full course, skin appears to be brightened and translucent and has less wrinkles. Two
courses help decrease facial fine lines, wrinkles and skin is more elastic. Three courses
help boot skin metabolism, prevent loose, sagging skin and delay skin aging.
Eye Care: 60 min, once/week
Microcurrent
roller energy
level:
20%-80%
Mode:
Lead out: ION+
Lead in:ION-
Makeup
remover+
Cleanser+
Toner+
Eye serum+
Eye mask+
SR-MJ3201
1. Remove makeup and
clean face, 5min.
2. Apply toner, 1 min.
3. Apply a layer of exfoliator
around eye area that is the
thickness of the a piece of
paper.
4. Have the customer hold
the passive electrode probe.
5. ION+ operation: Move
the probe in small circles
from the lower eyelid till the
temple, 3-5 times.
6. Lift from lower eyelid to
temple, 3-5 times.
7. Lift from the beginning of
the eyebrow to the end, 3-5
times.
8. Combined with hand, lift
from the canthus till
hairline, 3-5 times.
9. Do the same on the
other side.
10. Clean eye and face area,
2 min.
11. Rub essence evenly in
circles around eye area, 1
min.
12. Press on the following
acupoints with middle and
ring fingers: Bright
Technique5
Technique6,8
Technique7
Technique11,13,18
Technique12
Table of contents
Other mychway Medical Equipment manuals

mychway
mychway SM-7005N User manual

mychway
mychway WL-SW5 User manual

mychway
mychway BL-DT001 User manual

mychway
mychway MS-11R5 User manual

mychway
mychway WL-9392 User manual

mychway
mychway HR-P808S User manual

mychway
mychway MS-2178 User manual

mychway
mychway WL-SW6 User manual

mychway
mychway MS-34J1 User manual

mychway
mychway MS-2275 User manual

mychway
mychway MS-54K2 User manual

mychway
mychway MS-7008CX User manual

mychway
mychway SR-RU628 User manual

mychway
mychway MS-JS3000B User manual

mychway
mychway MS-6651 User manual

mychway
mychway MS-7206F User manual

mychway
mychway WL-7005C User manual

mychway
mychway MS-78S1 User manual

mychway
mychway MS-1163 User manual

mychway
mychway MS-PC422 User manual