NAPCO C 1000 STE User manual

Upon installation, a NAPCO Adaptive
Microwave/PIR Detector powers up, ini-
tialized in the first of its 12 senstivity
modes, i.e., the most sensitive, enabling it
to sample prevailing environmental condi-
tions. Faced with hostility or tranquility, the
Adaptive detector automatically selects the
most appropriate detection mode accord-
ingly, optimizing both intruder catch and
stability. Each time the sensors detect a
stimulus stong enough to generate a sig-
nal, but insufficient in strength to indicate
an alarm, the detector will automatically
change sensitivity modes, effectively wid-
ening the gap between the detected signal
and its alarm threshold. Therefore, environ-
mental disturbances, those that register by
the PIR and/or microwave sensor, are bet-
ter tolerated and the threat of false alarms
or nuisance alarms is dramatically reduced,
far surpassing the performance of con-
ventional dual technology devices. And,
because a dynamic Adaptive Detector
literally adjusts to its surroundings min-
ute-by-minute, once disturbances quiet,
e.g., the space heater turns off again, the
air conditioner stops blowing the blinds,
power stops browning-out, animals vacate
— the intelligent detector again escalates
its sensitivity, mode by mode — so the
premises always enjoys the greatest level
of fast intruder-catch detection and false
alarm protection possible.
The Napco Adaptive Sensor is the most
forgiving sensor available because it is so
smart and makes the sensitivity and critical
range adjustments an experienced alarm
professional would, if one were standing
by, 24-hours a day, seven days a week to
make them. Any activity beyond the unit’s
protected area, detected by the microwave
section is also automatically compensated
for. The unit even actively tests both its
channels (PIR and Microwave), regulary
activating each, to make sure it is on-
the-job, performing to specification. An
absolute solution to false alarms, callbacks
and service calls — NAPCO Adaptive
Detectors pay for themselves in the time
and money they save.
Manufacturing great security products is all we do. It’s that simple.™












































C100STE
standard
wide angle
lens
standard
NAPCO’s Adaptive® Dual
Microwave/PIR Detectors
automatically adjust to their
environment, minute by minute,
for the ultimate false alarm
immunity & reliability
SERIES
FEATURES
• Broad range and wide angle coverage suitable for most
residential & commercial installations worldwide: C100ST Series
(30 x 35’) 9.1 x 10.6m C100STE (US model); C100STE52 (European
model); C100STE11(UK model); C100STLR Series (50 x 40’ model)
15.2 x 12.2m: C100STLRE (US model); C100STLRE52 (European
model); C100STLRE15(UK model).
• Patented Adaptive® technology continuously monitors and
dynamically self-adjusts the sensor to its environment. This
ensures intruder “catch” sensitivity is optimized minute-by-minute,
while “phantom” false alarm sources, such as pets/animals, fans,
sunlight, HVAC, are simultaneously counteracted.
• Smart microprocessor-based false alarm discrimination. The
on-board A to D conversion microprocessor (Analog-to-Digital)
analyzes all incoming microwave and PIR detected signals against its
built in library of waveform signatures of known false alarm sources,
like heaters, fans, blowing drapes/blinds and animals. The product
of decades of sensor engineering and expertise, this inherent signal
processing intelligence, enables Adaptive® Detectors provides
unsurpassed false alarm discrimination the reliability and accuracy
will save both time and money.
• 12 automatically selected, dynamic Adaptive® detection modes
for optimal “intruder catch” and stability. (Modes 1-12: 1 most
sensitive, 12 most stable).
• Dual technology microwave and PIR signal verification. The
detector combines the strengths of both heat- and motion-sensitive
detection technologies to dually verify alarm conditions for ideal
false alarm discrimination.
• Active, automatic self-testing of all key components and circuits.
The unit will internally generate both a PIR signal and a microwave
signal, in intervals of 11- 16 hours, which will fully test both channels
independently. Any failure or internal trouble will be reported to
the system for quick remedy, avoiding any false sense of security or
breach thereof.
• Superior RFI-/EFI-/lightning shielded protection Key components
and resilient SMD circuitry are electronically-shielded to 30V/
m. This protects the unit’s proper performance from nuisance
interference due to static discharge, power surges, electric spikes,
etc.
• Optimized field-of-view with custom-engineered aspheric optics.
Napco’s fresnel lenses are carefully designed to provide the ideal
wide angle lens array and are easily-aimable during installation.
Additional field-changeable lenses available: Pet Alley, Barrier and
Long Range.
• Critical Range Control. Although the unit will adapt to effectively
ignore activity/interference beyond the protected area, the detector
enables manual, customizable range with a calibrated adjustable
potentiometer to fine-tune range during walk-test, if desired.
• True Automatic Temperature Compensation. The unit’s circuitry
automatically adjusts for seasonal and climate variances, providing
accurate detection despite extremes of heat or cold*.
• Fast, flexible mounting. The detector is conveniently installed on
walls or in a corner and may be more precisely aimed horizontally
or vertically, and offers an optional SVLBKT Swivel Bracket for
180º range of coverage. Large wiring channel, generous terminal
strip and captive PCB screw combine for fast, trouble-free, neat
installations every time.
NAPCO Product Availability Hotline
– C
all our Stock-Out Hotline at 1-800-645-9330 Press 1, pause then 2.
Or email us at hotline@napcosecurity.com
• Tamper/Vandalism Supervision. Defeats acts to sabotage or
vandalize the unit by reporting them to the system if opening
the enclosure is ever attempted. (International models also have
secured enclosures for added protection.)
• Added False Alarm Prevention Features. The unit employs
myriad features to ensure only valid alarms are reported in the
system. This includes properties of its circuitry and fresnel optics,
which include integral extra white light protection, a Napco-
pioneered innovation.
• Compliances: UL, CUL, CE, INCERT, NFA2P, NCP
SPECIFICATIONS
• Microprocessor: 2K ROM with A-D Converter
• Operating temperature*: -10 to +50 degrees C (14 º to 122º F)
• Mounting: Wall or corner, 12’ (3.6m) max.; For pet/animal
applications 7’ (2.1m) is recommended.
• Output relay: Form A; normally closed
• Relay time: Approx. 3 seconds
• Alarm Relay: 100mA, 24Vdc with internal 10 ohm current limiting
resistor
• Multi-mode Trouble Output (Open collector)
• Self-Test Interval: 11 - 16 hrs.
• Power supply requirements: Filtered 10.6 to 16VDC nominal with battery backup
form the control panel.
• Current drain: 28mA (idle/alarm) at 12VDC (nominal)
• Dimensions: 3.3”H x 2.5”W x 1.9”D (8.4 x 6.4 x 4.8 cm) (HxWxD)
• Shipping weight: 5 oz (142 gm)
NAPCO SECURITY GROUP
In North America 1-800-645-9445 • 631-842-9400
333 Bayview Avenue, Amityville, New York 11701 USA
www.napcosecurity.com
International
224 Europa Blvd, Gemini Business Park
Warrington WA5 7TN England UK
44 (0) 1925242428
Two decades of NAPCO sensor
engineering expertise combines to provide
its sensors with unsurpassed false alarm
prevention and intruder catch detection.
A363A
Tamper/Vandalism Supervision.
Defeats acts to sabotage or
C100STE

























standard wide
angle lens



















C100STE
Publicly traded on
NASDAQ
NSSC
SERIES

This manual suits for next models

8

Other NAPCO Security Sensor manuals

NAPCO GEM-HEAT User manual

NAPCO

NAPCO GEM-HEAT User manual

NAPCO GEM-GB User manual

NAPCO

NAPCO GEM-GB User manual

NAPCO GEMC-WL-CO User manual

NAPCO

NAPCO GEMC-WL-CO User manual

NAPCO C 200 AP User manual

NAPCO

NAPCO C 200 AP User manual

NAPCO PIR1680 User manual

NAPCO

NAPCO PIR1680 User manual

NAPCO IQ PROFILER - User manual

NAPCO

NAPCO IQ PROFILER - User manual

NAPCO PIR 1500-10 User manual

NAPCO

NAPCO PIR 1500-10 User manual

NAPCO GEMC-NL-MOD User manual

NAPCO

NAPCO GEMC-NL-MOD User manual

NAPCO PIR1680 Series User manual

NAPCO

NAPCO PIR1680 Series User manual

NAPCO PIR1680 Series User manual

NAPCO

NAPCO PIR1680 Series User manual

NAPCO C 100 SAFARI User manual

NAPCO

NAPCO C 100 SAFARI User manual

Popular Security Sensor manuals by other brands

ETC echoflex MOS-IR Series installation guide

ETC

ETC echoflex MOS-IR Series installation guide

Fieldpiece DR82 user manual

Fieldpiece

Fieldpiece DR82 user manual

PCB Piezotronics 105C12/003P20 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 105C12/003P20 Installation and operating manual

Milesight EM500 Series user guide

Milesight

Milesight EM500 Series user guide

Interlogix ACL800SUW-BSPX installation manual

Interlogix

Interlogix ACL800SUW-BSPX installation manual

SEW 302 SVD instruction manual

SEW

SEW 302 SVD instruction manual

Elkron IRA15P quick start guide

Elkron

Elkron IRA15P quick start guide

System Sensor 9440X FAAST Installation and maintenance instructions

System Sensor

System Sensor 9440X FAAST Installation and maintenance instructions

Radionics D9550 Nstallation instructions

Radionics

Radionics D9550 Nstallation instructions

Cedes TOF/Start Installation and operation manual

Cedes

Cedes TOF/Start Installation and operation manual

Autronica AutroFlame X33AF PL instructions

Autronica

Autronica AutroFlame X33AF PL instructions

Trotec SL800-SET operating manual

Trotec

Trotec SL800-SET operating manual

DAITEM 144-21X installation manual

DAITEM

DAITEM 144-21X installation manual

elock EL-PB60S manual

elock

elock EL-PB60S manual

B.E.G. LUXOMAT PD4-M-DALI/DSI-SM Installation and operating instruction

B.E.G.

B.E.G. LUXOMAT PD4-M-DALI/DSI-SM Installation and operating instruction

ESYLUX PD 360/8 Basic Detailed operating instructions

ESYLUX

ESYLUX PD 360/8 Basic Detailed operating instructions

Regin IRCW Instruction

Regin

Regin IRCW Instruction

WATSON INDUSTRIES ADS-C232-1A owner's manual

WATSON INDUSTRIES

WATSON INDUSTRIES ADS-C232-1A owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.