Cedes TOF/Start User manual

TOF/Start
Installation and Operation Manual
114 474 | 180219 | V 1.1
English Pages 2 – 11
CEDES AG is certified according to ISO 9001: 2015
RoHS

TOF/Start English
2 © CEDES | V 1.1
1. About this manual
This 'TOF/Start Installation and Operation Manual', with
metric and US measurements is the original version.
The version number is printed at the bottom of each page.
To make sure you have the latest version, visit www.cedes.
com from where this manual and related documents can
be downloaded.
1.1 Measurements
Measurements are, if not stated otherwise, given in
mm (non-bracketed numbers) and inches (numbers in
brackets).
1.2 Related documents
TOF/Start datasheet
001 231 en
1.3 CEDES headquarters
CEDES AG
Science Park
CH-7302 Landquart
Switzerland
CEDES AG reserves the right to modify or change technical data without prior notice.
Contents
1. About this manual 2
1.1 Measurements 2
1.2 Related documents 2
1.3 CEDES headquarters 2
2. Safety information 3
2.1 Non-intended use 3
3. Symbols, safety messages 3
3.1 Safety messages categories 3
4. Introduction 4
4.1 Application 4
4.2 Features of the TOF/Start 4
4.3 Type description 4
5. Configuration 4
5.1 Type of threshold setting 4
6. Installation 5
7. Input / Output description and
electrical connection 5
8. Start-up 5
9. Timing diagram 6
10. LED signals 7
11. Cross-traffic 7
12. Blanking 8
13. Trouble shooting 8
14. Maintenance 9
15. Disposal 9
16. Technical data 9
17. Dimensions 10
17.1 Sensor 10
17.2 Mounting bracket 10

TOF/Start English
© CEDES | V 1.1 3
2. Safety information
The TOF/Start was developed and manufactured using
state-of-the-art systems and technologies. However, injury
and damage to the sensor can still occur.
To ensure safe conditions:
Read all enclosed instructions and information.
Follow the instructions given in this manual carefully.
Observe all warnings included in the documentation
and attached to the sensor.
Do not use the sensor if it is damaged in any way.
Keep the instruction manual on site.
The TOF/Start should only be installed by authorized and
fully trained personnel! The installer or system integrator is
fully responsible for the safe integration of the sensor. It is
the sole responsibility of the planner and/or installer and/
or buyer to ensure that this product is used according to
all applicable standards, laws and regulations in order to
ensure safe operation of the whole application.
Any alterations to the device by the buyer, installer or user
may result in unsafe operating conditions. CEDES is not
responsible for any liability or warranty claim that results
from such manipulation.
Failure to follow instructions given in this manual and/
or other documents related to the TOF/Start may cause
customer complaints, serious call backs, damage, injury
or death.
2.1 Non-intended use
The TOF/Start must not be used for:
• Protection of dangerous machines
• Equipment in explosive atmospheres
• Equipment in radioactive environments
Use only specific and approved safety devices for such
applications, otherwise serious injury or death or damage
to property may occur!
3. Symbols, safety messages
3.1 Safety messages categories
Warning of serious health risks
Caution of possible health risk
Notice of damage risk
Symbol Meaning
Single instruction or measures in no
particular order
1.
2.
3.
Sequenced instructions
• List, in no order of importance
àReference to a chapter, illustration or
table within this document
Important Important information for the correct use
of the sensor
WARNING
Serious health risks
Highlights critical information for the safe
use of the sensor. Disregarding these
warnings can result in serious injury or
death.
Follow the measures highlighted by the
triangle-shaped arrows
Consult the safety information in
Chapter 2 of this manual
IMPORTANT
READ BEFORE INSTALLATION!
CAUTION
Possible health risks
Highlights critical information for the safe
use of the sensor. Disregarding these
warnings can result in injury.
Follow the measures highlighted by the
triangle-shaped arrows
Consult the safety information in
Chapter 2 of this manual
NOTICE
Risk of damage
Disregarding these notices can lead to
damage to the sensor, the door controller
and/or other devices.
Follow the measures highlighted by the
triangle-shaped arrows

TOF/Start English
4 © CEDES | V 1.1
4. Introduction
The TOF/Start is a compact yet powerful sensor which detects
people and objects approaching an escalator and speeds it up in
time for them to step comfortably and safely aboard.
The TOF technology enables the TOF/Start to operate with all types
of backgrounds without any need to recalibrate. Usually mounted
under the handrails or flush mounted in the balustrade at the
approach area, it offers excellent detection capability over an area
of up to 2 m x 2 m with a beam angle of up to 70°.
There are two versions of the TOF/Start:
• The TOF/Start Basic offers people/object detection and a
blanking function to blank out fixed objects, such as bollards.
• The TOF/Start Advanced offers these features plus a cross-
traffic function.
4.1 Application
Figure 1: TOF/Start detects intending passengers approaching
an escalator.
4.2 Features of the TOF/Start
• Excellent detection capability, independent of
reflectance
• Ignores cross-traffic via intelligent direction
recognition
• Individual setting of the detection area
• Detection area operates with all types of background
• Insensitive to ambient light
4.3 Type description
Figure 2: Type description
5. Configuration
5.1 Type of threshold setting
The distance at which the sensor triggers an output is the
threshold. The TOF/Start requires a threshold setting for
the x-axis; note that the y-axis is fixed at 2 m. A factory
setting as well as a mixture of potentiometer and preset
are also possible. For requirements regarding a variable
y-axis, please contact your local CEDES representative.
Note: The sensor uses a ±120 mm (±4.72 in) hysteresis.
The hysteresis is the difference between the switching points
changing the status from 'free field' to 'object detected' and
back from 'object detected' to 'free field' compared to the
nominal limit.
5.1.1 Threshold setting via potentiometer
The threshold distance at which the sensor triggers an
output is set with a potentiometer for the x-axis on both
the Basic and Advanced versions. This is done using the
potentiometer at the back of the sensor. If the sensor points
to a background, the distance of the switching threshold
to the background is recommended to be set at 150 mm.
TOF/Start – a – bb – c – d – e – fff; g; h,h*i,i
a: - Advanced
B Basic
bb : Aperture angle in °
Threshold
settings
Only if Preset
type
c: x-axis
N Potentiometer
d: y-axis
N Potentiometer
g: - Non-blanking
B Blanking
h,h : x-axis
Protection field in m
i,i : y-axis
Protection field in m
e: C Automatic calibration
fff : 1PP Output - PNP/NPN (push-pull)

TOF/Start English
© CEDES | V 1.1 5
Important:
The scale is not printed on the sensor. However the
potentiometer can be adjusted in five fixed steps of 0.2
m; starting at 0.6 m (at the 7 o'clock position) up to
1.4 m (at the 5 o'clock position); see Figure 3 below.
Take a small screw driver and turn the potentiometer
to the required position.
(all dimensions in mm)
Figure 3: Detection area using potentiometer
Table 1: Parameter - detection area
6. Installation
Important:
The TOF/Start must be mounted under the handrail at a
minimum 10° mounting angle to the ground facing
upwards.
Figure 4: Mounting angle of TOF/Start
7. Input / Output description and
electrical connection
Generally the TOF/Start has one output that is triggered
if the detection field is interrupted. For this purpose, a
push-pull output is used. With the logic selector (gray wire,
Figure 6), the logic of the output signal can be configured
for “HIGH“ on object or “LOW“ on object operation
(Figure 5), according to the controller requirements.
The logic selection is performed during start-up.
Figure 5: Output (PNP/NPN) logic
Figure 6: Connection diagram
8. Start-up
1. Switch on mains and power up.
2. Check if LED lights up.
3. Check the distance setting and the reaction of the
sensor, including the status LED, by placing an object
into the detection area at different heights and widths.
70°
20°
1.4 m
1.0 m
0.6 m
0.8 m 1.2 m
x-axis
x = min. 600 ... max. 1400
y = 2000
Parameter Value
Width (x-axis) Min.: 600 mm
Max.: 1,400 mm
Length (y-axis) 2,000 mm
Aperture angle 70°
USP
0 V
Output
Logic selector connected to GND (0 V)
USP
0 V
Output
Logic selector connected to U
SP
Controller
USP
GND (0 V)
n.c.
Selectable output logic
Output
n.c. = not connected and isolated
n.c.
black
brown
green
blue
white
gray
TOF/Start
10°

TOF/Start English
6 © CEDES | V 1.1
9. Timing diagram
Figure 7: General timing diagram
Figure 8: General timing table
On
Off
Object
No object
HIGH
LOW
HIGH
LOW
t2t3
t1t4
Off Dimmed Dimmed
Bright
XX
X
X
HIGH on object
Output
Power supply
LED status
LOW on object
Output
Object detection
Time Value [ms]
Power-on time t11,000
Max. response time
- TOF/Start Basic
- TOF/Start Advanced
• Area without cross-traffic < 1 m
• Area with cross-traffic > 1 m
t2
200
200
400
Release time t3200
Min. switching time t4200

TOF/Start English
© CEDES | V 1.1 7
10. LED signals
The red LED provides the sensor's status. The respective
LED is dimmed when the power is OK and the detection
field is free. The LED glows bright when an object is
detected and the respective output triggered. The LED is
visible from the front.
Figure 9: LED indicator
11. Cross-traffic
The TOF/Start Advanced features a cross traffic detection
function. If a person moves towards the escalator entrance
area, the TOF/Start Advanced triggers the output. If the
person only moves across the escalator entrance area, the
TOF/Start Advanced recognizes that the person does not
wish to use the escalator and does not trigger the output.
Important:
The cross-traffic activation zone begins at a 1 meter
distance from the sensor.
Figure 10: Detection field free; person moves towards the
escalator entrance area. LED status is dimmed.
Figure 11: Person is detected entering detection area, moving
towards the escalator entrance area. LED status is
bright.
Figure 12: Detection field free; Person moves to cross the
escalator entrance area. LED status is dimmed.
Figure 13: Sensor recognizes the person is moving cross the
escalator entrance. LED status remains dimmed
àno output switched.
LED dimmed LED bright
x
y
x
y
Area
without
cross-traffic
LED dimmed
LED bright
Area
without
cross-traffic
x
y
x
y
Area
without
cross-traffic
LED dimmed
LED bright
Area
without
cross-traffic
x
y
x
y
Area
without
cross-traffic
Area
without
cross-traffic
LED dimmed
LED dimmed
x
y
x
y
Area
without
cross-traffic
Area
without
cross-traffic
LED dimmed
LED dimmed
LED status Description
LED off No power
LED dimmed red No object detected
LED bright red Object detected

TOF/Start English
8 © CEDES | V 1.1
12. Blanking
Both TOF/Start versions feature a blanking function. The
TOF/Start triggers the output when objects are dynamic
(moving) within the detection field. Static objects within the
detection field will be ignored and blanked out (after 30
seconds). This covers with objects that are already present
at power up (i.e. bollards).
Start-up:
Figure 14: Active blanking - start-up sequence with i.e. bollards.
Figure 15: After start-up the bollards are blanked out
from the detection field.
Active blanking:
Figure 16: The detection field is free.
Figure 17: A static object is placed in the detection field
(i.e a trash bag). The object will be detected.
Figure 18: After 30 s the static object will be blanked out and
the TOF/Start continues its operation with the new
geometry of the detection field.
13. Trouble shooting
If the problem persists, please contact your local CEDES
representative (www.cedes.com).
LED dimmed
LED bright
LED dimmed
LED dimmed
Status Action
LED off Check supply power
Check electrical
connections
Object in the
safeguarded area and
LED dimmed red
Check distance setting
No object in the
safeguarded area and
LED bright red
Check electrical
connections
Check distance setting

TOF/Start English
© CEDES | V 1.1 9
14. Maintenance
Although the TOF/Start does not need regular
maintenance, a periodical functional check is strongly
recommended as follows:
Check the mounting position and detection area of the
sensor.
Clean the optical window with a soft towel and a little
soapy water.
15. Disposal
The TOF/Start should only be replaced if a similar
protection device is installed. Disposal should be done
using the most up-to-date recycling technology according
to local regulations and laws. There are no harmful
materials used in the design and manufacture of the
sensor. Traces of such dangerous materials may be found
in the electronic components but not in the quantities that
are harmful.
16. Technical data
Optical
Detection area
- Length (y-axis) 2,000 mm
- Width (x-axis) Min. 600 mm
Max. 1,400 mm
Mechanical
Dimensions (w × h × l) 57 × 34 × 44.5 mm
Housing material Polycarbonate
Housing color Black
Enclosure rating IP65
Temperature range −20 °C ... +65 °C
Electrical
Supply voltage USP 24 VDC ±20%
Current consumption 50 mA
at 24 VDC (peak max. 0.5 A)
Output PNP/NPN (push-pull)
Max. response time
- TOF/Start Basic 200 ms
- TOF/Start Advanced
• Area without cross-traffic < 1 m 200 ms
• Area with cross-traffic > 1 m 400 ms
Min. switching time 200 ms
Power-on time 1 s
Connection cable and electrical connection
Sensor
Length 0.25 m
Connection M8, 6-pin
Diameter Ø 4.2 mm
Material PVC, black
Plug color Blue
Connection cable
Length 2 m
(other lengths on request)
Connection M8, 6-pin
Diameter Ø 4.2 mm
Material PVC, black
Plug color Blue
Wires AWG26
• brown USP
• blue GND (0 V)
• black Output
• white Not connected
• gray Selectable output logic
• green Not connected
General
Eye safety EN 62471:2008
EMC emission EN 61000-6-3:2007
EN 12015:2014
EMC immunity EN 61000-6-2:2005
EN 12016:2013
Vibration IEC 60068-2-6:2007
Shock IEC 60068-2-27:2008
RoHS 2011/65/EU
Certificate CE
NOTICE
Damage to the optical window
Never use any solvents, cleaners or
mechanically abrasive towels or highpressure
water to clean the sensors.

TOF/Start English
10 © CEDES | V 1.1
17. Dimensions
17.1 Sensor
Measurements (all dimensions in mm and inches)
17.2 Mounting bracket
Measurements (all dimensions in mm and inches)
57 (2.24)
34 (1.34)
52 (2.05)
44.5 (1.75)
41.5 (1.63)
29 (1.14)
68.35 (2.69)
31.7 (1.25)
25°
33.35 (1.31)
40 (1.57)
51.4 (2.02)

TOF/Start English
© CEDES | V 1.1 11

CEDES AG, Science Park | CH-7302 Landquart
TOF/Start