GD34 RATES AND EFFICIENCIES BGD34 RATES AND EFFICIENCIES
NG LP NG LP
Altitude (FT) 0-4,500 0-4,500 0-4,500 0-4,500
Max. Input (BTU/HR) 22,000 22,000 15,000 15,000
Max. Output (BTU/HR) 18,040 18,040 11,700 11,700
Efficiency
(w/the fan on)
82% 82% 78% 78%
Min. Inlet Gas Supply
Pressure
4.5" Water Column 11" Water Column 4.5" Water Column 11" Water Column
Max. Inlet Gas Supply
Pressure
7" Water Column 13" Water Column 7" Water Column 13" Water Column
Manifold Pressure
(Under Flow
Conditions)
3.5" Water Column 10" Water Column 3.5" Water Column 10" Water Column
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.
W385-0393 / E
GD34-1
VENTED GAS FIREPLACE/
FOYER AU GAZ AVEC EVACUATION
$16,=E&6$E
DIRECT VENT VENTED GAS FIREPLACE HEATER. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME
INSTALLATION IF INSTALLED IN ACCORDANCE WITHTHE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR INTHE UNITED
STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETYSTANDARD, TITLE 24 CRF, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE, USE THE
STANDARD FOR FIRE SAFETY CRITERIAFOR MANUFACTURED HOME INSTALLATIONS, SITESAND COMMUNITIES,ANSI/NFPA501A.
APPAREIL DE CHAUFFAGE AU GAZ VENTILÉ AL’EVACUATION DIRECTE. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE ACOUCHER, UN SALLE DE BAIN ET UN
STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION CONFORMEAUX EXIGENCES DE LANORME CAN/CSA Z240MH SERIE DE
MAISONS MOBILES EQUIPEES AU GAZ, EN VIGEURAU CANADA OU AUX ETATS-UNIS DE LANORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES,
TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D’ETATS-UNIS NE PEUT ÊTREAPPLIQUEE, SE REFERER ALA NORME RELATIVEAU CRTERE DE MESURES
DE SECURITE CONTRE L’INCENDIE POUR LES INSTALLATIONS DANS LE MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES ANSI/NFPA 501A.
GD34-1NT GD34-1NTE
CDV34-1NT CDV34-1NTE
NATURAL GAS MODEL
GD34-1PT GD34-1PTE
CDV34-1PT CDV34-1PTE
PROPANE MODEL
0-4500FT (0-610M) ALTITUDE / ELEVATION 0-45FT (0-610M)
22,000 BTU/h INPUT / ALIMENTATION 22,000 BTU/h
13,500 BTU/h REDUCED INPUT / ALIMENTATION REDUITE 13,500 BTU/h
54% P4 54%
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
3.5” WATER COLUMN / COLONNE D’EAU MANIFOLD PRESSURE / PRESSION AU COLLECTEUR 10” WATER COLUMN / COLONNE D’EAU
4.5” WATER COLUMN / COLONNE D’EAU MINIMUM SUPPLY PRESSURE / PRESSION D’ALIMENTATION MINIMALE 11” WATER COLUMN / COLONNE D’EAU
7.0” WATER COLUMN / COLONNE D’EAU MAXIMUM SUPPLY PRESSURE / PRESSION D’ALIMENTATION MAXIMALE 13” WATER COLUMN / COLONNE D’EAU
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY. UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
APPAREIL. UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
WARNING: THIS FIREPLACE USESAND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE
ONLY WITHA FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEELLTD.
DO NOTADD ANY MATERIAL TOTHE APPLIANCE, WHICH WILLCOME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITHTHE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS / DEGAGEMENTS MINIMAUX DES
MATERIAUX COMBUSTIBLES:
TOP/DESSUS 0 RECESSED DEPTH / PROFOUND ENCASTRE 13”
FLOOR/PLANCHER 0 MANTEL/MANTEAU 2” *
SIDES/COTES 0 VENT TOP/EVENT SUPERIEUR 2”
BACK/ARRIERE 0 VENT BOTTOM /EVENT INFERIEUR 1”
VENT SIDES / COTES DE L’EVENT 1”
TOP, SIDES & BACK: PER STAND OFF SPACERS FOR FRAMING MATERIALS. FOR FINISHING
MATERIALS SEE OWNER’S MANUAL / DESSUS, COTES &ARRIERE: SELON LES ESPACEURS DE
DEGAGEMENT POUR LES MATERIAUX D’OSSATURE SELON LE MANUEL DE PROPRIETAIRE POUR
LES MATERIAUX DE FINITION.
* MAXIMUM HORIZONTAL EXTENSION / L’EXTENSION HORIZONTALE MAXIMALE: 2”.
SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL
D’INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON L4M 0G8 CANADA
AVERTISSEMENT: CE FOYER UTILISE ET REQUIRET UN THEROMOCOUPLE ÀACTION RAPIDE. REMPLACEZ
UNIQUEMENTAVEC UNTHERMOCOUPLE À ACTION RAPIDE DE WOLF STEELLTÉE.
N’AJOUTEZ PAS ACET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE
QUE CELUI QUI EST FOURNIAVEC CETAPPAREILPAR LE FABRICANT.
THE APPLIANCE MUSTBE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNER’S
INTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATIONAND RESEALING IS NECESSARY
AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
L’APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L’ENSEMBLE D’EVACUATION PROPREA WOLF STEEL.
REFERER AU MANUELD’INSTALLATION DE PROPRIETAIRE POUR L’EVACUATION PRECISE. IL IMPORTANT DE BIEN
REINSTALLER ET RESCELLER L’EVENTAPRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D’AIR.
THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITHAIR FILTERS.
CETAPPAREILDE CHAUFFAGE AU GAZ NE DOIT PAS ÊTRE UTILISÉ CONJOINTEMENT AVEC DES FILTRES ÀAIR.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ550-1KT
SERIAL NUMBER / NO. DE SERIE:
2.4 RATING PLATE INFORMATION
A Z240MH SERIES GAS EQUIPPE
CRF, PART 3280. WHENTHIS US S
S AND COMMUNITIES,ANSI/NF
ETATS-UNIS DE LA NORME DE SECURITE
TS-UNIS NE PEUT ÊTREAPPLIQUEE, SE R
E MAISONS MANUFACTURES, LES SIT
MANIFOLD PRESSURE / PRESS
MUM SUPPLY PRESSURE / PRESSION
M SUPPLY PRESSURE / PRESSION
ACERS FOR FRAMING MATERIALS. F
ESSUS, COTES & ARRIERE: SELON L
X D’OSSATURE SELON LE MANUEL DE P
AL EXTENSION / L’EXTENSION HOR
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
fire-parts.com