8
W415-1293 / 08.10.15
EN
2.4 RATING PLATE INFORMATION
W385-2069
CONFORMS TO / CONFORMEAUX:ANSI Z21.50-2014, CERTIFIEDTO / CERTIFIE CSA2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
FOYER À GAZ VENTILÉ DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE ACOUCHER,
UNE SALLE DE BAIN ET UN STUDIO.APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORMEAUX EXIGENCES DE LANORME CAN/CSAZ240MH SERIE DE MAISONS
MOBILES EQUIPEES AU GAZ, EN VIGUEURAU CANADAOUAUX ETATS-UNIS DE LANORME DE SECURITE
ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU
CETTE NORME D'ETATS-UNIS NE PEUT ETREAPPLIQUEE, SE REFERERALANORME RELATIVE AU
CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES
MAISONS MANUFACTURES, LES SITES ETLES COMMUNAUTES,ANSI/NFPA 501A.
POUR UNE UTILISER
AVEC BARRIÈRE W565-0150. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE
TROUVENT DA NS LE MANUEL D'INSTALLATION.
DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN
ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED
MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US
STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITESAND COMMUNITIES,ANSI / NFPA 501A. FOR
USE WITH BARRIER W565-0150. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE
INSTALLATION MANUAL.
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
0-4500FT (0-1370m) ALTITUDE / ELEVATION 0-4500FT (0-1370m)
22,000 BTU/h INPUT / ALIMENTATION 22,000 BTU/h
17,300 BTU/h REDUCED INPUT /ALIMENTATION REDUITE 19,500 BTU/h
MANIFOLD PRESSURE: 3.5" (9MB) WATER COLUMN MANIFOLD PRESSURE: 10" (25MB) WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" (9 MB) D'UNE COLONNE D'EAU PRESSION AU COLLECTEUR: 10" (25MB) D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" (11MB) WATER COLUMN MINIMUM SUPPLY PRESSURE: 11" (27MB) WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" (11MB) D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MINIMALE: 11" (27MB) D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" (17MB) WATER COLUMN MAXIMUM SUPPLY PRESSURE: 13" (32MB) WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 7.0" (17MB) D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MAXIMALE: 13" (32MB) D'UNE COLONNE D'EAU
P4: 65% P4: 65%
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS DOORS
CERTIFIED WITH THIS UNIT ONLY.
WARNING: THIS FIREPLACE USES AND REQUIRES A FASTACTING THERMOCOUPLE. REPLACE
ONLY WITH AFAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOTADDANY MATERIAL TO THEAPPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. MINIMUM CLEARANCE
TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS 0 RECESSED DEPTH / PROFONDEUR D'ENCASTRE 18"
FLOOR / PLANCHER 0 VENT SIDES / COTES DE L'EVENT 1"
SIDES / COTES 0 VENT TOP/ EVENT SUPERIEUR 3"
BACK / ARRIERE 0 VENT BOTTOM / EVENT INFERIEUR 1"
MANTEL / MANTEAU 2" *
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION
MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUELD'INSTRUCTION POUR DES
EXTENSIONS PLUS GRANDES.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUMAND MAXIMUM VENT LENGTHS.
REFERER AU MANUELD'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS
D'EVACUATION MINIMALE ET MAXIMALE.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
APPAREIL. UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT: CE FOYER UTILISE ET REQUIERT UNTHERMOCOUPLE ÀACTION RAPIDE.
REMPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE.
N’AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
THE APPLIANCE MUSTBE VENTED USING THEAPPROPRIATE WOLF STEEL VENT KITS. SEE OWNERS
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATIONAND RESEALING IS
NECESSARYAFTER SERVICINGTHE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE ANAPOLEON.
REFERER AU MANUELD'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST
IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENTAPRESAVOIR ASSURE LE MAINTIEN DU
SYSTEME DE PRISE D'AIR.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
PRODUIT DÉCORATIF: NE PAS UTILISER COMMEAPPPAREIL DE CHAUFFAGE.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: EP35
SERIAL NUMBER/NO. DE SERIE: B42
B42NTR CB42NTR MODEL CB42PTR B42PTR
B42NTRE CB42NTRE CB42PTRE B42PTRE
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
PPROPRIE POUR INSPPROPRIE POUR I
UX EXIGENCES DE LA NORX EXIGENCES DE LA NO
N VIGUEUR AU CANADAOUAUX EVIGUEUR AU CANADAOUAUX E
AISONS MANUFACTUREES,TITRE 24 CSONS MANUFACTUREES,TITRE 24 C
NIS NE PEUT ETREAPPLIQUEE, SE REFER
PEUT ETREAPPLIQUEE, SE REFER
DE SECURITE CONTRE L'INCENDIE POUR LE CONTRE L'INCENDIE POUR
TURES, LES SITES ET LES COMMUNAUTES,ET LES COMMUNAUTES
AVEC BARRIÈRE W565-0150. SUIVEZ LES65-0150. SUIVEZ LES
TROUVENT DA NS LE MANUEL D'INSTTROUVENT DA NS LE MANUEL D'INS
-4500FT
0-1370m
22,000 BTU
TATION REDUITE 19,500 BTU/hATION REDUITE 19,500 BTU/h
MANIFOLD PRESSURE:MANIFOLD PRESSURE:
RESSION AU COLLECTEUR:
INIMUM SUPPLY PRESSURE
PRESSION D'ALIMENTATION MIPRESSION D'ALIME
MAXIMUM SUPPLY PRESSURMAXIMUM SUPPLY PR
PRESSION D'ALIMENTATIOPRESSION D'ALIMENTAT
65
4:
5
CT WITH THE FLAMES,HE FLAMES,
E. MINIMUM CLEARANCEEARANCE
'ENCASTRE 18"ENCASTRE 18"
1
1
RIZONTALE MAXIMALE: 2". SEE INSTRUCTZONTALE MAXIMALE: 2". SEE INSTRUC
ANUEL D'INSTRUCTION POUR DESANUEL D'INSTRUCTION POUR DES
FOR MINIMUM AND MAXIMUM VENTLENFOR MINIMUM AND MAXIMUM VENTL
ON DE PROPRIETAIRE POUR LES LONGU
N DE PROPRIETAIRE POUR LES LONG
P