7
W415-1132 / C / 08.20.13
EN
2.3 GENERAL INFORMATION
When the appliance is installed at elevations above 4,500 ft (1371m), and in the absence of specific recom-
mendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced
at the rate of 4% for each additional 1,000 ft (305m).
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Use only accessories designed for and listed with your specific appliance.
APPLIANCE
NG LP
Altitude (FT) 0-4,500 0-4500
Max. Input (BTU/HR) 17,000 17,000
Max. Output Steady State (BTU/HR) 10,900 10,900
Efficiency (w/the fan on) 64% 64%
A.F.U.E. (Annual Fuel Utilization Efficiency) 53% 53%
Min. Inlet Gas Supply Pressure 4.5" (11mb) w.c. 11" (27mb) w.c.
Max. Inlet Gas Supply Pressure 7" (17mb) w.c. 13" (32mb) w.c.
Manifold Pressure (Under Flow Conditions) 3.5" (9mb) w.c. 10" (25mb) w.c.
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
2.4 RATING PLATE INFORMATION
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
W385-0342 / H
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA2.22b-2009,ANSI Z21.50b-2009 VENTED GAS FIREPLACE / FOYERAU GAZ AVEC EVACUATION.
FOYER A GAZ VENTILE DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE
SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS
MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE
SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280.
DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETREAPPLIQUEE, SE REFERER ALA NORME
RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS
DANS LES MAISONS MANUFACTURES, LES SITES ETLES COMMUNAUTES, ANSI/NFPA501A. LORSQU'IL
EST INSTALLE AVEC LATROUSSE POUR ECRAN GD-565KT, LE FOYER EST CONFORME ALANORME DE
CERTIFICATION DE L'ACG CR95-006.
DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE
WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES,
IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED
HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. WHEN INSTALLED
WITH SCREEN KIT GD-565KT, THE FIREPLACE COMPLIES WITH CGA CERTIFICATION
REQUIREMENT CR95-006.
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
BGD36CFNTR BCDV36CFNTR MODEL BGD36CFPTR BCDV36CFPTR
0-4500FT (0-1370m) ALTITUDE / ELEVATION 0-4500FT (0-1370m)
17,000 BTU/h INPUT / ALIMENTATION 17,000 BTU/h
12,000 BTU/h REDUCED INPUT /ALIMENTATION REDUITE 12,000 BTU/h
MANIFOLD PRESSURE: 3.5" WATER COLUMN MANIFOLD PRESSURE: 10" WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING: THIS FIREPLACE USES AND REQUIRESA FAST ACTINGTHERMOCOUPLE. REPLACE
ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOTADD ANY MATERIAL TO THE APPLIANCE, WHICH WILLCOME IN CONTACT WITH THE FLAMES,
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS 0 RECESSED DEPTH / PROFONDEUR D'ENCASTRE 17.25"
FLOOR / PLANCHER 0 VENT SIDES / COTES DE L'EVENT 1"
SIDES / COTES 0 VENT TOP/ EVENT SUPERIEUR 2"
BACK / ARRIERE 0 VENT BOTTOM / EVENT INFERIEUR 1"
MANTEL / MANTEAU 12" *
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION
MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUELD'INSTRUCTION POUR DES
EXTENSIONS PLUS GRANDES.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUMAND MAXIMUM VENT LENGTHS.
REFERER AU MANUELD'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS
D'EVACUATION MINIMALE ET MAXIMALE.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC
CET APPAREIL. UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT:
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE ÀACTION RAPIDE.
REMPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE.
N’AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
THE APPLIANCE MUSTBE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNERS
INSTALLATION MANUALFOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS
NECESSARYAFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPREA NAPOLEON.
REFERER AU MANUELD'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. ILEST
IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRESAVOIR ASSURE LE MAINTIEN DU
SYSTEME DE PRISE D'AIR.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ550-KT, GD65
SERIAL NUMBER/NO. DE SERIE: BGD36CF
Z AVEC EVACUATIOAVEC EVACU
UR INSTALLATION DANS UR INSTALLATION DANS
PRIE POUR INSTALLATION DANRIE POUR INSTALLATION DA
IGENCES DE LA NORME CAN/CSANCES DE LA NORME CAN/CS
EN VIGUEUR AU CANADA OU AUX ETATEUR AU CANADA OU AUX ETAT
UCTION DE MAISONS MANUFACTUREES, TITRESONS MANUFACTUREES, TITRE
E NORME D'ETATS-UNIS NE PEUT ETREAPPLIQUEE, SE
S NE PEUT ETREAPPLIQUEE, SE
RE DE MESURES DE SECURITE CONTRE L'INCENDIE PORE DE MESURES DE SECURITE CONTRE L'INCENDIE PO
ONS MANUFACTURES, LES SITES ETLES COMMUNAUTESNS MANUFACTURES, LES SITES ETLES COMMUNAUTES
LE AVEC LATROUSSE POUR ECRAN GD-565KT, LE FOYER EEC LATROUSSE POUR ECRAN GD-565KT, LE FOYER
4001659 (WUSA)4001659 (WUSA)
-4500FT
0-1370m
17,000 BTU/
T /ALIMENTATION REDUITE 12,000 BTU/hT /ALIMENTATION REDUITE 12
ANIFOLD PRESSURE:
RESSION AU COLLECTEUR:
MINIMUM SUPPLY PRESSURE:MINIMUM SUPPLY P
COLONNE D'EAUCOLONNE D'EAU
PRESSION D'ALIMENTATIONPRESSION D'ALIMENT
7.0" WATER COLUMN7.0" WATER COLUMN
MAXIMUM SUPPLY PRESMAXIMUM SUPPLY PRE
" D'UNE COLONNE D'EAUD'UNE COLONNE D'EAU
PRESSION D'ALIMENPRESSION D'ALIMEN
ST ACTING THERMOCOUPLE. REPLACEST ACTING THERMOCOUPLE. REPLACE
BY WOLF STEEL LTD.WOLF STEEL LTD.
IN C
NTACT WITH THE FLAMES,
IN CONTACT WITH THE FLAMES
URER WITH THE APPLIANCE.H THE APPLIANCE.
SED DEPTH / PROFONDEUR D'ENCASTRE 17.25"SED DEPTH / PROFONDEUR D'ENCASTRE 17.25"
T SIDES / COTES DE L'EVENTT SIDES / COTES DE L'EVENT
1
VENT TOP / EVENT SUPERIEURENT TOP / EVENT
VENT BOTTOM / EVENT INFERIEUR
VENT BOTTOM / EVENT INFERIEUR
ENSION / L'EXTENSION HORIZONTALE MAXIMA
SION / L'EXTENSION HORIZONTALE MAXIM
SIONS. REFERER AU MANUELD'INSTRUC
ONS. REFERER AU MANUELD'INSTRUC
CTION MANUAL FOR MINIMUMANUAL FOR MINIMU
NSTALLATION DE PROPRALLATION DE PROP