2.6 RATING PLATE INFORMATION
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate
information. For French rating plate remove the plate, flip over and reattach.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
EPI3 , LISTED SOLID FUEL BURNING FIREPLACE INSERT. TESTED TO ULC S628-93 / UL 1482-2011
CHIMNEY CONNECTOR: 6” (152mm)
DO NOT CONNECT THIS UNIT TO A
CHIMNEY FLUE SERVINGANOTHER
APPLIANCE.
FUEL: FOR USE WITH SOLID WOOD
FUEL ONLY. DO NOT USE GRATE OR
ELEVATE FIRE - BUILD WOOD FIRE
DIRECTLY ON HEARTH.
WARNING: RISK OF SMOKE SPILLAGE.
OPERATE ONLY WITH DOOR FULLY
CLOSED. REPLACE GLASS ONLY WITH THE
CERAMIC GLASS. DO NOT OVERFIRE. IF
HEATER OR CHIMNEY CONNECTORS GLOW,
YOU ARE OVERFIRING. INSPECTAND
CLEAN CHIMNEY FREQUENTLY. UNDER
CERTAIN CONDITIONS OF USE, CREOSOTE
BUILD UP MAY OCCUR RAPIDLY.
BLOWER KIT: 115V, 60HZ, 1.5AMP. ROUTE
CORD AWAY FROM UNIT.
DANGER: RISK OF ELECTRICAL SHOCK.
DISCONNECT POWER BEFORE SERVICING
UNIT.
INSTALL AND USE ONLY INACCORDANCE
WITH THE MANUFACTURER’S INSTALLATION
AND OPERATION INSTRUCTIONS. INSTALL
AND USE ONLY IN MASONRY FIREPLACE OR
FACTORY BUILT FIREPLACE. CONTACT
LOCAL BUILDING OR FIRE OFFICIALSABOUT
RESTRICTIONS AND INSTALLATION
INSPECTION IN YOUR AREA.
HEARTH EXTENSION/FLOOR PROTECTION:
MUST BE NON COMBUSTABLE AND HAVE A
MINIMUM THICKNESS OF 0.5” WITHA THERMAL
CONDUCTIVITY FACTOR (K) 0.84 AND
RESISTANCE VALUE (R) 0.59.
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH.
KEEP CHILDREN AND CLOTHING AND
FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.
MINIMUM CLEARANCE TO COMBUSTIBLE
MATERIALS (MEASURED FROM INSERT BODY)
A ADJACENT SIDEWALL A) 12”/305mm
B MANTEL B) 16”/406mm
C TOP FACING C) 16”/406mm
D SIDE FACING D) 6”/152mm
EPI3 DATE CODE
W385-0678
Pour le français, l'étiquette arrière.
INSTALL ONLYON ANON-COMBUSTIBLE HEARTH RAISED (F) 1.5 IN /
38MM ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE
FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL
EXTENDING (E) 16 in / 450MM (US), 18 IN / 456MM (CAN) TO FRONT
AND (G) 8 IN / 205 MM TO SIDES FROM FUELDOOR. FOR
ADDITIONAL MANTELINFORMATION SEE OWNER’S INSTRUCTION
MANUAL
NACGUANGZHOUP.R.C.
NO.69 HEFENG ROAD,
GUANGZHOU,CHINA
24 NAPOLEON ROAD, BARRIE, ON,
L4M 0G8 CANADA
WOLFSTEELLTD.
U.S. Environmental Protection Agency Certified to comply with July 1990,
particulate emissions standards: /
40 CFR Part 60, Subpart AAA
NAC
214 BAYVIEW DRIVE, BARRIE, ON
L4N 4Y8 CANADA
103 MILLER DRIVE
CRITTENDEN, KY 41030-7560
WOLFSTEELUSA
415-S-11-2
A
C
D
B
EPI3, FOYER ENCASTRÉ À COMBUSTIBLE SOLIDE HOMOLOGUÉ. TESTÉ SELON LES NORMES
ULC S628-93 / UL 1482-2011
AVERTISSEMENT : RISQUE D’ÉCHAPPEMENT
DE FUMÉE. TENIR LAPORTE FERMÉE
LORSQUE LE POÊLE FONCTIONNE. EMPLACEZ
LA VITRE PAR UNE VITRE EN CÉRAMIQUE
SEULEMENT. NE SURCHAUFFEZ PAS
L’APPAREIL. SI L’APPAREIL OU LES RACCORDS
ROUGEOIENT, L’APPAREIL SURCHAUFEE.
INSPECTEZ ET NETTOYEZ LACHEMINÉE
FRÉQUEMMENT. DANS CERTAINES
CONDITIONS, DES DÉPÔTS DE CRÉOSOTE
PEUVENT SE FORMER RAPIDEMENT.
INSTALLER ET UTILISER SELONS LES
INSTRUCTIONS DU FABRICANT. INSTALLER
ET UTILISER DANS UN FOYER DE
MACONNERIE OU PRÉFABRIQUÉ.APPELER
VOTRE INSPECTEUR DE BÂTIMENT OU LE
DÉPARTMENT D’INCENDIE LOCAL POUR LES
CODES LOCAUX ET POUR INSPECTÉE
VOTRE INSTALLATION ET FOYER.
ATTENTION :
QUAND L’APPAREIL FONCTIONNE, LA
SURFACE DEVIENT CHAUDE. NE PAS
TOUCHER. TENIR LES ENFANTS, LES
VÊTEMENTS ET LES MEUBLES À L’ÉCAR. LE
CONTACT PEUT CAUSER DES BRÛLURES À
LA PEAU. W385-0679
INSTALLER SUR UN ÂTRE DE MATÉRIAUX INCOMBUSTIBLE SURÉ-
LEVÉ (F) 1,5 POUCES / 38MM DESSUS DU PLANCHER COMBUSTIBLE
ADJACENT. LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR
LE MATERIAUX INCOMBUSTIBLE QUI ÉTENDRE. (E) 16 IN / 405MM
(ETATS-UNIS) 18 IN / 457MM (CAN) ENAVANT ET (G) 8IN / 205MM LES
CÔTÉ DE LA PORTE. POUR DE PLUS AMPLES RENSEIGNEMENTS
SUR LE MANTEAU, CONSULTEZ LE MANUEL D’INSTRUCTIONS.
U.S. Environmental Protection Agency Certifié
conforme à la norme d’ émanation de particles de juillet 1990
40 CFR Part 60, Subpart AAA
BDÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES:
(À PARTIR DE L’APPAREIL)
A CÔTÉ A) 12”/305mm
B DESSUS B) 16”/406mm
C TABLETTE C) 16”/406mm
D MUR LATÉRAL D) 6”/152mm
For English see Reverse
Pour la date et le numéro de série, voir le revers.
415-S-11-2
SOUFFLERIE: 115V, 60HZ, 1.5AMP. TENEZ
LE CORDON ÉLECTRIQUE LOIN DE
L’APPAREIL.
DANGER: RISQUE DE SECOUSSE
ÉLECTRIQUE. DÉBRANCHEZ AVANTDE
PROCÉDER À L’ENTRETIEN.
RACCORD DE CHEMINÉE : 6” (152mm)
NE PAS RACCORDER À LA CHEMINÉE D’UN
AUTRE APPAREIL.
COMBUSTIBLE : POUR USAGE AVEC LE
BOIS SOLIDE SEULEMENT. N’UTILISEZ
PAS DE CHENET OU NE SURÉLEVEZ
PAS LE BOIS - PRÉPAREZ LE FEU
DIRECTEMENT SUR L’ÂTRE.
BASE DE PROTECTION/
PROTECTION DE PLANCHER:
DOIT ÊTRE INCOMBUSTIBLE ET
AVOIR UNE ÉPAISSEUR
MINIMALE DE 0,5” AVEC UN
COEFFICIENT DE CONDUCTIVITÉ
THERMIQUE (K) DE 0,84 ET UN
COEFFICIENT DE RÉSISTANCE
THERMIQUE (R) DE 0.59.
A
C
D
DING OR FIRE OFFICIALS ABOUT
RTH EXTENSION/FLOOR PROTECTIO
MUST BE NON COMBUSTABLE AND
MINIMUM THICKNESS OF 0.5” WITHA THE
CONDUCTIVITY FACTOR (K) 0.84 AND
RESISTANCE VALUE (R) 0.59.
WHILE IN OPERATION. DO NOT TOUC
E PAS RACCORDER À LA CHEMINÉE D’UN
BOIS SOLIDE SEULEMENT. N’UTILISE
PAS DE CHENET OU NE SURÉLEVEZ
PAS LE BOIS - PRÉPAREZ LE FEU