NCR SelfServ 84 Walk-Up User manual

NCRSelfServ™84Walk‐UpStandard Collar ATMSitePreparation
B006‐7519‐G000

B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
TheproductdescribedinthisdocumentisalicensedproductofNCR
Corporation.
NCRandNCRSelfServaretrademarksofNCRCorporation.Otherproduct
namesmentionedinthispublicationmaybetrademarksorregistered
trademarksoftheirrespectivecompaniesandareherebyacknowledged.
Wherecreationofderivativeworks,modificationsorcopiesofthisNCR
copyrighteddocumentationispermittedunderthetermsandconditionsofan
agreementyouhavewithNCR,NCR'scopyrightnoticemustbeincluded.
ItisthepolicyofNCRCorporation(NCR)toimproveproductsasnew
technology,components,software,andfirmwarebecomeavailable.NCR,
therefore,reservestherighttochangespecificationswithoutpriornotice.
Allfeatures,functions,andoperationsdescribedhereinmaynotbemarketed
byNCRinallpartsoftheworld.Insomeinstances,photographsareof
equipmentprototypes.Therefore,beforeusingthisdocument,consultwith
yourNCRrepresentativeorNCRofficeforinformationthatisapplicableand
current.
NCRProprietaryInformation‐nottobedisclosedorreproducedwithout
writtenconsent.
©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.
AllRightsReserved

NCRSelfServ™84Walk‐UpATMSitePreparation
i
NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
Contents
Introduction
Audience...............................................................................................1‐1
AboutThisDocument ...........................................................................1‐1
RevisionRecord ....................................................................................1‐1
CustomerResponsibilities
Notice ...................................................................................................2‐1
SiteCompliance ....................................................................................2‐1
CustomerActions .................................................................................2‐1
StandardsCompliance
RadioFrequencyInterference ..............................................................3‐1
FCCRadioFrequencyInterferenceStatement ................................3‐1
CanadianClassADeviceDeclaration...............................................3‐1
Safety ....................................................................................................3‐1
SafetyDirective................................................................................3‐1
HarmonisedSafetyStandard...........................................................3‐1
ElectromagneticCompatibility(EMC)...................................................3‐1
ImmunityStandards ........................................................................3‐1
EMCDirectives.................................................................................3‐1
EmissionStandards..........................................................................3‐1
AdditionalRequirementsfor220V‐240VUnits .............................3‐1
Accessibility ..........................................................................................3‐1
ProductOverview
GeneralDescription ..............................................................................4‐1
Options ............................................................................................4‐1
Acoustics...............................................................................................4‐1
HeatDissipation....................................................................................4‐1
ProductIdentification...........................................................................4‐1
SiteRequirements
PositioningtheATM .............................................................................5‐1
Floor......................................................................................................5‐1
DoorwaysandCorridors .......................................................................5‐1
Wall.......................................................................................................5‐1
WallCavity.......................................................................................5‐1
InstallingThroughaGlassWall........................................................5‐1
CollarTolerance...............................................................................5‐1
AmbientLighting...................................................................................5‐1
TaskLighting .........................................................................................5‐1
TemperatureandHumidity ..................................................................5‐2
NormalOperatingRange(InteriorEnvironment)............................5‐2
NormalOperatingRange(ExteriorEnvironment) ...........................5‐2
StorageRange(UpToThreeMonths) .............................................5‐2
TransitRange(UpToOneWeek) ....................................................5‐2
ExtremePowerOnRange(UpToOneHour) ..................................5‐2
BarometricPressure ............................................................................. 5‐2
PowerRequirements
ACPowerRequirements....................................................................... 6‐1
InputVoltageSetting............................................................................ 6‐1
Grounding............................................................................................. 6‐1
TransientProtection............................................................................. 6‐1
CableRequirements
CablePreparation................................................................................. 7‐1
DataLineTransientProtection.............................................................7‐1
AlarmInterfaceCables ......................................................................... 7‐1
BasicAlarmCable ............................................................................ 7‐1
EnhancedAlarmCable .................................................................... 7‐1
RemoteStatusMonitor ........................................................................ 7‐2
ShorteningtheCable....................................................................... 7‐2
RemoteRelayCable.............................................................................. 7‐2
EthernetStandardCable ......................................................................7‐2
PowerCable.......................................................................................... 7‐2
Decals
AdvertWindow .................................................................................... 8‐1
AdvertCollarorOpenAdvertCollar................................................8‐1
Entry/ExitDecals ..................................................................................8‐1
VariantDetails‐CENI,StandardCollarATM
PackageDimensions ............................................................................. 9‐1
ATMDimensions................................................................................... 9‐1
WeightandFloorLoading .................................................................... 9‐1
StandardSecurityEnclosures ..........................................................9‐1
CableEntry ...........................................................................................9‐1
FaciaItems............................................................................................ 9‐2
15”Touchscreen.............................................................................. 9‐2
19”Touchscreen.............................................................................. 9‐2
TouchscreenDimensions ................................................................ 9‐2
HeightsandDepths .........................................................................9‐2
DistanceforVoiceGuidance ...........................................................9‐2
SecurityBolts........................................................................................9‐3
BoltHoles ............................................................................................. 9‐3
ShortSleeve..................................................................................... 9‐3
LongSleeve...................................................................................... 9‐3
HoleintheWall .................................................................................... 9‐4
HoleatOptimumHeight .................................................................9‐4
HoleatLoweredHeight................................................................... 9‐4
HoleintheWallOverlap‐StandardCollar‐ATM...........................9‐5
VentsLocation‐AirFlow......................................................................9‐5
Clearances‐TopboxDoor .................................................................... 9‐5
Clearances‐Corridor............................................................................9‐5
ServicingAreas‐Optimum‐SingleATM.............................................. 9‐6
ShortSleeve .................................................................................... 9‐6
LongSleeve ..................................................................................... 9‐6
ServicingAreas‐Optimum‐SideBySide ............................................ 9‐7
ShortSleeve .................................................................................... 9‐7
LongSleeve ..................................................................................... 9‐7
ServicingAreas‐Minimum‐SingleATM ............................................. 9‐8
ShortSleeve .................................................................................... 9‐8
LongSleeve ..................................................................................... 9‐8
ServicingAreas‐Minimum‐SideBySide ............................................ 9‐9
ShortSleeve .................................................................................... 9‐9
LongSleeve ..................................................................................... 9‐9

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
1‐1Introduction
AUDIENCE
Thisdocumentisintendedforarchitectsandthoseresponsibleforpreparinga
sitepriortothearrivaloftheATM.
ABOUTTHISDOCUMENT
Thissitepreparationdocumentisdesignedtobereadonwideaspectratio
screens.Eachsectionhasbeenstructuredtofitthemaximumamountof
informationontheminimumnumberofpagesyetstillbereadablewhen
printedonA3sizepaper.Printingonsmallerpapersizesmayreducereadability
butwillmakehandlingeasier.
Thedocumentisorganisedintosectionscoveringthefollowingtopics:
Introduction‐thissection
CustomerResponsibilities
StandardsCompliance
ProductOverview
SiteRequirements
PowerRequirements
CableRequirements
Decals
VariantDetails‐CENI,StandardCollarATM
VariantDetails‐CENI,OpenCollarATM
VariantDetails‐CENI,StandardAdvertCollar
VariantDetails‐CENI,OpenAdvertCollar
VariantDetails‐CENIIIandIV,StandardCollarATM
VariantDetails‐CENIIIandIV,OpenCollarATM
VariantDetails‐CENIIIandIV,StandardAdvertCollar
VariantDetails‐CENIIIandIV,OpenAdvertCollar
Eachpagehastwoorthreecolumnslaidoutasfollows:
WhereleftandrightsidearestatedtheATMisviewedfromthefront(facia
side)oftheATM.Allplanviewsarefromthetopunlessotherwisestated.
Unlessotherwisestatedalldimensionsareroundedtothenearestmillimetre
andequivalentdecimalofaninch.
REVISIONRECORD
Publication ID
Copyright
Publication name Section name Section number Page number
Column 1 Column 2 Column 3
Date Revision Pages Reason for Change
January 2017 A All Initial release
February 2017 BVarious Hole at Lowered Heights table updated
All modules above 15” touchscreen removed
August 2017 C 9-4, 10-4, 11-4
12-4 Update to Australia plinth height, 5 high 15 in. display
September 2017 DVarious CEN III and IV (Std and GAS EX) added
Modules above 15” touchscreen added to Open collars
Hole at Lowered Heights - new table covering modules
above 15” touchscreen
Safety standard and directive updated
Product Identification label updated
Service clearances updated - LHS/RHS deposit modules
Topbox Clearance added
Note added to weight and floor loading sections
September 2017 E Various Hole at Lowered Heights - update to table covering no
modules above touchscreen
February 2018 F9-2,11-2,13-2&
15-2
9-4,11-4,13-4&
15-4
Modules above 15” touchscreen added back in
(Std and Std Advert Collars)
Modulesabove15”touchscreeninstallationheightstable
added back in
March 2018 G 9-4, 10-4, 11-4,
12-4,13-4,14-4,
15-4, 16-4
Installation height tables updated, 1mm removed from
US plinth and bottom of hole dims

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
2‐1CustomerResponsibilities
NOTICE
Thisisacontractualdocument.Itcontainsimportantwarningsandconfers
importantlegalrightsandobligations.Youareadvisedtoreaditcarefully.
Itistheresponsibilityofyou,thecustomer,toassurethatallinstallation
preparationsarecompleteandincompliancewithallspecificationsand
requirementsofNCRandallapplicablenational,state,orlocalcodes,
regulationsandlaws.
Thisequipmentmustbeinstalledandusedinstrictaccordancewiththe
manufacturer’sinstructions.However,thereisnoguaranteethatinterference
toradiocommunicationswillnotoccurinaparticularcommercialinstallation.If
thisequipmentdoescauseinterference,whichcanbedeterminedbyturning
theequipmentoffandon,theuserisencouragedtoconsultanNCRservice
representativeimmediately.
CAUTION NCRCorporationisnotresponsibleforanyradioortelevision
interferencecausedbyunauthorizedmodificationsofthis
equipmentorthesubstitutionorattachmentofconnectingcables
andequipmentotherthanthosespecifiedbyNCR.Such
unauthorizedmodifications,substitutions,orattachmentsmay
voidtheuser’sauthoritytooperatetheequipment.Thecorrection
ofinterferencecausedbysuchunauthorizedmodifications,
substitutions,orattachmentswillbetheresponsibilityoftheuser.
SITECOMPLIANCE
Thisdocumentcontainstheinformationnecessaryforthepreparationofasite
conformingtoNCRspecifications.Itisveryimportantthatthesitecomplies
withtherequirementsspecifiedinthisdocument,because,oncethe
equipmenthasbeeninstalled,deficienciesinsitepreparationortheproblems
causedbythesedeficienciesaremuchmoredifficulttodetectandcorrect.
Further,failuretocomplywiththeserequirementsortotakeproperstepsto
protectequipmentagainstrisksidentifiedinthisdocumentmaycauseserious
damagetotheequipmentandtothecustomer’sbusiness.
Inadditiontotheneedtocomplywiththerequirementsspecified,electrical
wiringandmechanicalsystemsmustalsocomplywithallrelevantcodes,laws
andregulations.
Itisimportantthatthesitebepreparedbyacustomerorhisagentwhoisfully
conversantwiththespecialrequirementsofelectronicequipment.The
responsibilityforensuringthatthesiteispreparedincompliancewiththis
documentremainswiththecustomer.
Forinformationandguidancepurposesonly,alistisprovided,ingeneralterms,
ofthosemattersforwhichthecustomerisresponsible.Thislistisnotintended
tobecomprehensive,andinnowaymodifies,alters,orlimitstheresponsibility
ofthecustomerforallaspectsofadequatesitepreparation.
NCRstaffwillbeavailabletoanswerquestionsrelatingtothecontentsofthis
documentbut,exceptwhere:
a. thecustomerhasbeennotifiedthatafullorpartialconsultancyservice
isavailableand/orthatNCRwillbewillingtoundertakeapreliminaryor
finalsitesurveyand
b. thecustomershallhaveenteredintoaformalcontractwithNCRfor
provisionofthesame
nocomment,suggestionoradviceofferedornotofferedaboutpreparationof
thesitenoranyinspectionofthesitewhetherbeforeorafterpreparationisto
betakenasapprovalofthelocationofthesiteandequipmentorofits
preparationandNCRwillnotbeliableinrespectofanycomment,suggestionor
advicegivenbyitsstafforinrespectofanyfailuretogiveadvice.
Finally,onlythecustomercanknowthefullextentofdamagewhich
maybecausedtohisbusinessbyreasonoffailureoftheequipment
whichistobeinstalled.Forthisreasonitisthecustomer’sresponsibility
toascertaintheextentofanysuchpossibledamagetohisexistingor
plannedbusiness,andtoeffect,fullinsuranceinrespectofit.
CUSTOMERACTIONS
Thecustomermustdoorprovidethefollowing:
WhenrequiredbyNCR,providetheNCRcustomerservice
representativewithappropriatedrawingsthatindicate:
Locationoftheequipment
Sitewiring(powerandsignal,pathsandlengths)
Locationofotherequipmentcapableofgeneratingelectricalnoise,
electromagneticinterference,heat,etc.
Makebuildingalterationsnecessarytomeetwiringandothersite
requirements.
Provideandinstallallcommunicationscables,walljacks,special
connectors,andassociatedhardware.
Provideandinstallnecessarypowerdistributionboxes,conduits,
grounds,lightningprotection,andassociatedhardware.
Makesureallapplicablecodes,regulationsandlaws(including,butnot
limitedto,electrical,building,safety,andhealth)aremet.
Provideandinstallauxiliarypowerorotherequipmentasrequired.
Providestorageorserviceareasasrequired.
Makesuretheenvironmentalrequirementsofthesystem/unitaremet.
Providefloorcoveringsandenvironmentalsystemsthatlimitorcontrol
staticelectricitybuild‐upanddischarge.
Installtheproductataheightwhichmeetstheaccessibilityregulations
oftherelevantcountry.

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
3‐1StandardsCompliance
RADIOFREQUENCYINTERFERENCE
FCCRadioFrequencyInterferenceStatement
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClass
Adigitaldevice,pursuanttoPart15oftheFederalCommunications
Commission(FCC)Rules.Theselimitsaredesignedtoprovidereasonable
protectionagainstharmfulinterferencewhentheequipmentisoperatedina
commercialenvironment.Thisequipmentgenerates,uses,andcanradiate
radiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe
instructionmanual,maycauseharmfulinterferencetoradiocommunications.
Operationofthisequipmentinaresidentialareaislikelytocauseharmful
interferenceinwhichcaseyou,thecustomer,willberequiredtocorrectthe
interferenceatyourownexpense.
CanadianClassADeviceDeclaration
ThisdigitalapparatusdoesnotexceedtheClassAlimitsforradionoise
emissionsfromdigitalapparatussetoutintheRadioInterferenceRegulations
oftheCanadianDepartmentofCommunications.
Leprésentappareilnumériquen’émetpasdebruitsradioélectriquesdépassant
leslimitesapplicablesauxappareilsnumériquesdelaclasseAprescritesdansle
Réglementsurlebrouillageradioélectriqueédictéparleministèredes
CommunicationsduCanada.
SAFETY
SafetyDirective
73/23/EEC,93/68/EEC‘LowVoltageDirectiveandAmendment’.
HarmonisedSafetyStandard
EN60950‐1:2006+A2:2013‘InformationTechnologyEquipment‐
Safety’
ELECTROMAGNETICCOMPATIBILITY(EMC)
ImmunityStandards
TheATMcomplieswiththefollowingrequirementsforradiatedandconducted
immunity:
EN55024(1998)/+A1:2001,A2:2003
AspertherequirementsofEN55024,theATMcomplieswiththerequirements
ofthefollowingnormativeImmunityStandard:
EN61000‐4‐2ElectrostaticDischarge
EN61000‐4‐3RadiatedRF
EN61000‐4‐4ElectricalFastTransient/Burst
EN61000‐4‐5Surge
EN61000‐4‐6ConductedRF
EN61000‐4‐8PowerFrequencyMagneticField
EN61000‐4‐11VoltageDips/ShortInterruption.
EMCDirectives
Thisequipmenthasbeenfoundtocomplywiththeessentialrequirementsof
EMCDirective2014/30/EU,bytestingtoharmonizedstandardsEN55032,
EN55024,EN61000‐3‐2andEN61000‐3.Theequipmentcomplieswiththe
limitsforaClassAdigitaldevice,pursuanttoEN55032.
TheATMcomplieswiththefollowingElectromagneticCompatibility(EMC)
directivesandstandardsforITequipment:
2014/30/EU‘EMCDirective’
93/68/EEC‘CEMarkingDirective’
EmissionStandards
TheATMcomplieswiththefollowingrequirementsforradiatedandconducted
emissions:
EN55032ClassA
FCC47CFRPart15.ClassA
CISPR32ClassA
AS/NZS3548ClassA
GB9254ClassA
CNS13438ClassA.
WARNING ThisequipmentiscompliantwithClassAofCISPR32.Ina
residentialenvironmentthisequipmentmaycauseradio
interference.
AdditionalRequirementsfor220V‐240VUnits
TheATMcomplieswiththefollowingrequirementsforconductedemissions:
EN61000‐3‐2:2000,Mainsharmonics,ClassA
EN61000‐3‐3:1995/+A1:2001,Mainsflicker.
ACCESSIBILITY
Itistheresponsibilityoftheowninginstitutiontoensurethattheheightsfrom
thefloorleveltothefaciaitemscomplywithanylocalregulations.
Note: Theheightslistedinthisdocumentassumethattheinstallationdoes
notadddepthinfrontoftheATM.Increaseddepthmaychangethe
heightrequirementsduetoincreasingtheuser’sreach,therefore
pleaserefertotherelevantaccessibilityregulationifadditionaldepth
hasbeenadded.

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
4‐1ProductOverview
GENERALDESCRIPTION
TheNCRSelfServ84Walk‐UpAutomatedTellerMachineisa‘throughthewall’
ATMwhichmaybeinstalledthroughanysuitableexteriorwallorinavestibule
location.
TherearenoseparateVestibuleorThroughtheWallvariantsoftheSelfServ84.
Alldimensionsandclearancesarethesameforbothtypesofinstallation.
Options
StandardSecurityEnclosures
CENGradeI
CENGradeIII
CENGradeIV
SolidandGasExplosionResistant(EXGAS)SecurityEnclosures
CENGradeIII
CENGradeIV
Sleeve
ShortSleeve
LongSleeve
Collars
Standard
StandardAdvert
Open
OpenAdvert
ACOUSTICS
Formostvariantstheacousticssoundpowerdoesnotexceed:
65dB(A)whenidle
68dB(A)whenoperating(seenote).
However,thefollowingconfigurationswillaffectthesoundlevelsasshownin
thetablebelow:
HEATDISSIPATION
TheNCRSelfServproductrangeisaflexiblehardwareplatform.NCR
recommendsthatactualpowermeasurementsaretakenandusedtoestablish
theheatdissipationforspecifichardwareconfigurations.Thesemeasurements
shouldincludeanycustomorthirdpartyfeatures.
Wherespecificmeasurementsarenotavailablethen,asaguide,760KJ/hour
canbeusedasanindicativeheatingload.ThisfigureisbasedonanATMinidle
mode,withamediumtohighfeaturefunctionalityconfiguration.
Heatdissipationfiguresarelargelyunaffectedbytransactionalrates.
PRODUCTIDENTIFICATION
Theillustrationbelowistypicalofthelayoutoftheproductidentificationlabel
whichisfixedinsidetheATM.
Theproductisidentifiedbyaclassanda4digitmodelnumber.Theserial
numberisuniquetoeachATM.Thetracernumberisusedtoidentifywherethe
ATMwasbuilt.
Pleasequotealloftheserialandtracernumbers,includingtheprefix,when
makingreferencetotheATM.
Electricalratinginformationisalsoshownontheproductlabel.
Configuration Acoustic sound power when operating
Coin and passbook does not exceed 72 dB(A)
Cooling fans does not exceed 75 dB(A)
Model: XXXX
Hz: 50/60 A: X.X
XX - XXXXXXXX
Tracer: Serial:
Vãc:
NCR Global Solutions Ltd.
NCR SelfServ XX
™
Made in UK
Electromagnetic Compatibility
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio Interference
Regulations of Canada.
Complies with FDA Radiation Performance Standards 21 CFR Subchapter J
Class: XXXX
XX - XX
Manufactured: Xxxxxx XXXX
XXX - XXXv
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le
ministère des Communications du Canada.
Safety Certification Marks are located in this section

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
5‐1SiteRequirements
POSITIONINGTHEATM
TheATMmaybeinstalledthroughanysuitableexteriorwallorvestibule
location.
IftheATMisfittedwithaPassbookPrinter,itshouldneverbeexposedtorain
andthereforeonlysuitableforinteriorinstallations.
TheATMmustalsobepositionedawayfromheatsourcesoranyair
conditioningequipment.
Brightlightsandwindowsbehindtheusermaydegradecameraperformance.
PositiontheATMawayfromdirectsunlight.
Allowsufficientroomforinstallationandservicingrequirements.
FLOOR
TheATMmustbeinstalledonalevel,even,concreteorothernoncombustible
surface.Inlocationswherethefloormaybeuneven,itisrecommendedthata
steelplateisusedundertheATM.
Anantistaticfloorcoveringshouldbeusedandmustbeofatypethatwillnot
generatedustorfluff.
TheATMmustbeinstalledonafloorcapableofsupportingthemaximum
weightincludingmedia.Onlythemaximumweightshouldbeconsideredas
additionaloptionsmaybeaddedafterinstallation.Floorloadingiscalculatedby
dividingthemaximumweightoftheATMbythesurfaceareaoftheATMbase
incontactwiththefloor.
Serviceareas,ATMweightsandfloorloadingforyourATMcanbefoundinthe
VariantDetailssections.
DOORWAYSANDCORRIDORS
Makesurethatdoorwaysandcorridorsleadingtoyourpointofinstallationare
wideenoughtoallowthepackagetopassthrough,ormakearrangementsto
unpacktheATMandremoveitfromthepalletinanareawithsufficientaccess
thenmoveittotheinstallationsite.
MakesurethatanycorridorscansupporttheweightoftheATM,includingall
packagingandthepallet.
WALL
A25mm(1.0in.)widesmoothsurfaceisrequiredaroundtheedgeofthewall
openingtoenableagoodweatherseal.
WallCavity
Anycavityinthewallmustbesealedtoprovideaflushsurfacethatdoesnot
extendintothewallopening.LeavethegapbetweentheATMsleeveandthe
wallopeningcleartoallowairatroomtemperaturetocirculate.
InstallingThroughaGlassWall
IfyouareinstallingyourATMthroughaglasswallyoumayrequireasuitable
glasssupport(normallyasteelcollar)tositbetweentheATMcollarandthe
glass.Therequirementforthissupportshouldbedeterminedbythearchitect.
Ifrequired,anysuchsupportshouldbesourcedlocally.
CollarTolerance
Thecollarhasatoleranceof±4mm(0.2in.(±0.5°))atthetopandbottom,with
0mm(0.0in.(0°))atitscentre.
Thecollarcannotaccommodatelargedipsordepressionsinthewall.Make
surethewallissmoothandeven.
AMBIENTLIGHTING
IftheATMisfittedwithacamera,itisstronglyrecommendedthatthereisa
minimumof50LUXlightingatfloorlevelwithintheareaillustratedbelow.
TASKLIGHTING
Aminimumof200LUXisrequiredfortasklighting.
0 mm
(0.0 in.)
±4 mm
(0.16 in.)
±4 mm
(0.16 in.)
1500 mm
(59.1 in.)
1000 mm
(39.4 in.)

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
SiteRequirements
NCRSelfServ™84Walk‐UpATMSitePreparation
5‐2
TEMPERATUREANDHUMIDITY
Continuousoperatingatorneartherangelimits,orinalocationwherethe
temperatureandhumiditychangebeyondthespecification,shouldbeavoided.
Ifinstallingthoughanexteriorwall,thesitemustmeettherequirementsof
boththeInteriorandExteriorenvironments.
Note: ForexteriorthroughthewallATMsthehumidityinsidethebuildingis
restrictedtoamaximumof30%atanoutsidetemperatureof‐35°C
(‐31°F),withalinearrelationshipbetweentemperatureandhumidityto
amaximumhumidityat0°C(32°F).
NormalOperatingRange(InteriorEnvironment)
Temperature:0°Cto40°C(32°Fto104°F)
RelativeHumidity:20%to80%
DewPointTemperatureRestriction:26°C(79°F)maximum
NormalOperatingRange(ExteriorEnvironment)
Temperature:
withoutPassbookPrinter:‐35°Cto50°C(‐31°Fto122°F)
withPassbookPrinter:0°Cto40°C(32°Fto104°F)
RelativeHumidity:
withoutPassbookPrinter:10%to100%
withPassbookPrinterfitted:10%to80%
DewPointTemperatureRestriction:26°C(79°F)maximum
StorageRange(UpToThreeMonths)
Temperature:‐10°Cto50°C(14°Fto122°F)
RelativeHumidity:10%to90%
TransitRange(UpToOneWeek)
Temperature:‐40°Cto60°C(‐40°Fto140°F)
RelativeHumidity:5%to95%
ExtremePowerOnRange(UpToOneHour)
Temperature:0°Cto45°C(32°Fto113°F)
RelativeHumidity:10%to95%
BAROMETRICPRESSURE
Operating/TransitLimits:105kPa(15.2lbf/in2.)to70kPa(10.2lbf/in2.)
EquivalentAltitude:Uptoamaximumof3000m(9842.52ft)

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
6‐1PowerRequirements
ACPOWERREQUIREMENTS
Themaximumcurrentrequirementsare:
10Aat120V
6.3Aat230V.
Themaximuminrushcurrentis100A.
NCRdoesnotrecommendrunninganATMwithdepositdeviceswithoutan
UninterruptiblePowerSupply(UPS).WithoutaUPS,thereisthepotentialfor
customer’scashtoberetainedinthedeviceifthereisapowerfailure.
INPUTVOLTAGESETTING
TheATMcanoperatefromthefollowinginputmainsvoltages:
90Vto136Vat50/60Hz
180Vto264Vat50/60Hz.
GROUNDING
TheATMoperatesfromasinglephase,3wiresupply:live,neutralandground.
TheATMpowerrequirementswillnormallypermitittooperatewithinexisting
wiringconfigurationsandfromexistingmainsoutletsprovidedthat:
thebranchcircuitofthedistributionpanelsupplyingtheATMisnotalso
usedtosupplyequipmentwithheavyinductiveloadssuchasair
conditionersorACmotors.
otherbranchcircuitsonthesamedistributionpaneldonotsupplysuch
equipment.
theinstallationmeetsorexceedstheregulatoryandlocalguidelines
withregardtoelectricalsafetyandallconductorsizing.
ThenormalandsafeoperationofthisATMisdependentontheabove.Only
qualifiedpersonnelthatmeetlocalcertificationstandardsshouldbepermitted
toensurecompliance.
Notethatthebuildinggroundpointcanalsoaffectdataintegrity.Foradditional
informationrefertoDataLineTransientProtectionintheCableRequirements
section
TRANSIENTPROTECTION
Intheprocessofpowerdistribution,transientelectricalenergy(including,but
notlimitedto,lightningstrikes,intermittentshortcircuits,andswitching
transients)canbeintroducedontopowerlines.Suchtransientenergycanbe
verydamagingtoelectronichardwareandcanalsocausedatacorruption.
Underthesecircumstances,NCRrecommendstheuseofACpowertransient
suppressorsanddata(communication)linetransientsuppressors.Such
protectivedevicesareintendedtoguardagainstpoweranddatalinetransients
thatcanresultinhardwaredamageandvarioussystemorprogramerrors.
Improvementofanydeficienciesinpowerqualityisacustomerresponsibility.
Malfunctionand/orcomponentfailureasaresultofpowerqualityproblems
are/isnotcoveredbyNCRCorporationMaintenanceAgreement.NCRaccepts
noliabilityforanysuchoccurrencenorforitsconsequences.
Whenpowertransientsuppressionisrequired,thesuppressorsusedshould
meetthefollowingminimumrequirements:
Dissipateenergytomatchtheappropriateapplicationcategoriesas
definedbyANSI/IEEEStandardC62.41,GuideonSurgeVoltagesinLow‐
VoltageACPowerCircuits.
Beofthevoltagelimiting(clipping),ortrackingfiltertype.The
suppressormustnot‘clamp’thevoltagetozero,andmustself‐recover
afterthepassageofthetransient.Thesuppressormaybeofthehybrid
typeconstructionthatmakesuseofvarioustechnologiesinorderto
meetspeedanddissipationrequirements.
Exhibita‘shortcircuit’modeuponitsfailure,thusprovidingapositive
indicationofitsfailuresuchasablownfuseortrippedbreaker
Belistedbytheacceptedsafetyorganizationforthecountryinvolved
(e.g.UL,CSA,VDE,ETL,etc.)andtheinstallationmustconformtolocal,
state,andnationalelectricalcodesandregulations.
Location Category Comparable to IEC
No 664 Category Transient
Waveform Amplitudes
B = Major feeders, short branch
circuits, and load centres III
Volts = 1.2 x 50 s
Current = 8 x 20 s
and
0.5 Rise - 100 kHz
Ringwave
6kV
3kA
6kV
500A
C = Service Entrance and run to
load centre IV Volts = 1.2 x 50 s
Current = 8 x 20 s 10kV or more
10kA or more

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
7‐1CableRequirements
CABLEPREPARATION
NCRsupplyapowercablefortheATM.Otherexternalcablesarenotsupplied.
Specificationsforthesecablesaregiveninthissection.
Itisthecustomer’sresponsibilitytohaveanyrequiredexternalcablesinstalled
andtomakesurethatallcablepreparationscomplywithNCRspecificationsas
wellaswithallnational,stateorlocaltelephoneandtelegraphregulationsand
laws.
Whenproducingcablesallowfor2.2m(7.22ft)ofcablewithintheATM.
DATALINETRANSIENTPROTECTION
Voltagetransients,linenoise,surges,sags,impulses,andspikesmaybe
experiencedroutinelyorsporadically.Whensuchphenomenaoccurtheuseof
protectivedevicesmayberequiredtoensureproperoperationofthe
equipment.
Itistheresponsibilityofthecustomertoinstallandconnectadataline
transientsuppressionsystemtocorrectorpreventanydeficiencies.Such
systemsmustmeetthefollowingminimumrequirements:
Beoftheself‐recoveringvoltagelimitingtype.Exhibita‘shortcircuit’mode
uponitsfailuretoensureapositiveindicationofitsfailure.Insertminimum
inductiveandcapacityloadingattheoperatingfrequency.Beinstalledin
accordancewithallapplicablelocal,state,andnationalelectricalcodesand
regulations.
Protectthedataportfromdamageinthepresenceofadatalinetransient
eventasdefinedinIECStandard1000‐4‐5(formerlyIEC801‐5).
ALARMINTERFACECABLES
TheATMmayoptionallybeconfiguredtoprovideanalarminterfacewhich
enablestheATMtobeconnectedtoanexternallocalalarmsystem.The
interfacemaytaketheformofoneoftwooptions;abasicalarmsystemoran
enhancedalarmsystem.
Astabilised,non‐interruptiblepowersupplymustbeprovidedthroughthe
externalalarmsystem.Thealarminterfacecablewiringmustconformtothe
followingspecification:
12V±2Vdc
200mAmaximum
Ripple,5%maximum.
BasicAlarmCable
Removea20mm(0.79in.)sectionoftheoutersleeve,100mm(3.94in.)from
theATMendofthecable.
Takecarenottocutthroughthecableshielding.
EnhancedAlarmCable
Removea20mm(0.79in.)sectionoftheoutersleeve,100mm(3.94in.)from
theATMendofthecable.
Takecarenottocutthroughthecableshielding.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1, 2, 5, 6
3
4
1. Connector, 25 Way (NCR part no. 006-0005896)
2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, multiconductor (determined by the alarm installed).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006- ).
6. Screw retainer (NCR part no. 601-0101584).
1500038
Chassis GND
Silent Alarm Common *
Door Alarm N.O.
Door Alarm N.C.
Common
+12V
Silent Alarm N.O. *
Silent Alarm N.C. *
Door Alarm Common
N.O.
N.C
+12V Return
Vibration/Heat
Vibration/Heat
Vibration/Heat
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
* Optional
20 mm
(0.79 in.)
100 mm
(3.94 in.)
1, 2, 5, 6
3
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1. Connector, 25 Way (NCR part no. 006-0005896)
2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, multiconductor (determined by the alarm installed).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006- ).
6. Screw retainer (NCR part no. 601-0101584).
1500038
Chassis GND
Test Transmitter A
Tamper Alarm N.O.
Tamper Alarm N.C
Silent Alarm Common *
Door Alarm N.O.
Door Alarm N.C.
Composite Attack Common
+12V
Test Transmitter B
Tamper Alarm Common
Silent Alarm N.O. *
Silent Alarm N.C. *
Door Alarm Common
Composite Attack N.O.
Composite Attack N.C
+12V Return
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
* Optional
20 mm
(0.79 in.)
100 mm
(3.94 in.)

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
CableRequirements
NCRSelfServ™84Walk‐UpATMSitePreparation
7‐2
REMOTESTATUSMONITOR
Theremotestatusmonitorfeatureissuppliedasacompleteassembly
consistingofastatusindicatorunit,76.2m(250ft)ofcableandaconnector.
Removea20mm(0.79in.)sectionoftheoutersleeve,70mm(2.76in.)from
theATMendofthecable.
Takecarenottocutthroughthecableshielding.
ShorteningtheCable
Ifyouneedtoshortenthecable,proceedasfollows:
1. Removethecoverfromtheremotestatusindicatorunit
2. Disconnectthefourleads(E1,E2,E3andE4)fromtheindicator
3. Cutthecabletotherequiredlengthandstripthefourwireends
4. Connectthewirestothecorrectterminals
5. Replacethestatusindicatorcover.
REMOTERELAYCABLE
Theremoterelayprovidesapairofopencontacts,ratedat28voltsperampere
forbothacanddcsupplies,whichcanbeclosedtoactivatearemotedevice.
Theinterconnectingcabletoaremotedevicemustconformtothefollowing
specificationandwiring:
Removea20mm(0.79in.)sectionoftheoutersleeve,100mm(3.94in.)from
theATMendofthecable.
Takecarenottocutthroughthecableshielding.
ETHERNETSTANDARDCABLE
Theethernetstandardcablemustbefullyshielded,8pin,Category5compliant
andmustnotexceed97m(318.20ft)inlength.
Removea40mm(1.57in.)sectionoftheoutersleeve,80mm(3.15in.)from
theATMendofthecable.
Takecarenottocutthroughthecableshielding.
POWERCABLE
TheATMissuppliedeitherasa120Vora220‐240Vunit.
120VATMsaresuppliedwithapowercablefittedwithaNEMAtype5‐15P
powersourceconnector.
220‐240VATMsaresuppliedwithanunterminatedpowercable.Information
aboutsuitablepowerconnectorsissuppliedwiththeaccessories.
Thepowercablesuppliedis3m(9.84ft)inlength.Ifitisnecessarytoincrease
thislengthtomeetsiterequirements,thentheextensionmustsatisfylocalor
countryregulations.
WARNING Thisequipmentmustbeearthed.
70 mm
(2.76 in.)
20 mm
(0.79 in.)
(Green) E1
(Red) E2
(White) E3
(Black) E4
Red
Yellow
Green
1
2
1, 2 34
Rl1
RL2
1. Connector, 2 way Mate-N-Lock (NCR part no. 007-9814285).
2. Terminal wire, male (NCR part no. 007-2009663).
3. Cable, multiconductor (NCR part no. 006-5800006).
4. Connector (determined by remote device).
20 mm
(0.79 in.)
100 mm
(3.94 in.)
40 mm
(1.57 in.)
80 mm
(3.15 in.)

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
8‐1Decals
ADVERTWINDOW
Thedecalsshouldbeamaximumof0.75mm(0.0295in.)thick.
AdvertCollarorOpenAdvertCollar
ENTRY/EXITDECALS
Entry/Exitdecalsshouldbeamaximumof0.5mm(0.02in.)thick.NCR
recommendstheybemadefromtexturedpolycarbonatewith3M467High
PerformanceMPadhesive.
Decalsshouldprovidegoodcontrast,atleast70%,betweenforeground(text/
icon)andbackground.
Asansseriftypefaceshouldbeused(Tiresiasisrecommended).Thetextsize
shouldbeatleast14point,andlargerwherepossible.Wheretactiledecalsare
requiredtheyshouldbedesignedinlinewithspecificcountryrequirements.
Suggestedicondesignsandwordingareshownbelow:
CAUTION Whenplacinganycardreaderdecal,makesurethatthelabeldoes
notobscurethecontactlesscardreaderorcardreaderentryslot
lights.
CAUTION DoNOTplaceanymetalliccoatedorsubstratelabelontheglass
areaaroundtheCCRorcardreader,highlightedbelow:
595.5 mm
(23.44 in.)
2.5 mm
(0.10 in.)
Radius in
four corners
160 mm
(6.30 in.)
Cash Deposit
Cash Dispense
Receipt
Cash
Dispense/Deposit Cheque Deposit
1234 5678 9
Coin Dispense
Statement
Cash/Cheque
Deposit
1234 5678 9
Statement and
Passbook Printer
Passbook Printer
12 mm
(0.47 in.)
75 mm
(2.95 in.)

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
9‐1VariantDetails‐CENI,StandardCollarATM
PACKAGEDIMENSIONS ATMDIMENSIONS WEIGHTANDFLOORLOADING
Note: Themaximumweightcoversthemaximumconfigurationpossiblefor
theATM.Thiswillincludeallmodules(coindispenser,cashacceptor,
statementprinter,etc)fullyloadedwithmedia.
StandardSecurityEnclosures
CABLEENTRY
1989 mm
(78.31 in.)
1398 mm
(55.04 in.)
950 mm
(37.40 in.)
958 mm
(37.72 in.)
1405 mm
(55.31 in.)
A
A - 1847 mm (72.72 in.) with a 5 High Security Enclosure
1729 mm (68.07 in.) with a 4 High Security Enclosure
Note 1
340 mm
(13.39 in.)
1248 mm
(49.13 in.)
including
lock
66 mm
(2.60 in.)
801 mm
(31.54 in.)
373 mm
(14.68 in.)
1134 mm
(44.65 in.)
including
lock
1513 mm
(59.57 in.)
770 mm
(30.31 in.)
832 mm
(32.76 in.)
*664 mm
(26.14 in.)
800 mm
(31.50 in.)
801 mm
(31.54 in.)
259 mm
(10.20 in.)
226 mm
(8.90 in.)
66 mm
(2.60 in.)
Note 1
60 mm
(2.36 in.)
681 mm
(26.81 in.)
502 mm
(19.76 in.)
62 mm
(2.44 in.) Note 2
Note 2
62 mm
(2.44 in.)
1631 mm
(64.21 in.)
770 mm
(30.31 in.)
744.5 mm
(29.31 in.)
615 mm
(24.21 in.)
271.5 mm
(10.69 in.)
626.5 mm
(24.67 in.)
615 mm
(24.21 in.)
271.5 mm
(10.69 in.)
950 mm
(37.40 in.)
60 mm
(2.36 in.)
681 mm
(26.81 in.)
502 mm
(19.76 in.)
*782 mm
(30.79 in.)
800 mm
(31.50 in.)
719 mm
(28.31 in.)
719 mm
(28.31 in.)
* Dimensions are the same for short or long sleeve options
: 610 mm (24.02 in.) without cash camera
617.3 mm (24.30 in.) including cash camera
Note 1
Note 2: 98 mm (3.86 in.) without cash camera option
90.7 mm (3.57 in.) with cash camera option
4 High Security
Enclosure
5 High Security
Enclosure
4 High Security
Enclosure
5 High Security
Enclosure
Short Sleeve Long Sleeve
CEN Grade I
4 High CEN Grade I
5 High
Maximum weight 904.70 kg
(1994.52 lb.) 949.70 kg
(2093.73 lb.)
Floor loading 1469 kg/m2
(300.8 lb./ft2)1542 kg/m2
(315.7 lb./ft2)
555 mm
(21.85 in.)
212 mm
(8.35 in.)
33 mm
(1.30 in.)
65.5 mm
(2.58 in.)
800 mm
(31.50 in.)
770 mm
(30.31 in.)

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
VariantDetails‐CENI,StandardCollarATM
NCRSelfServ™84Walk‐UpATMSitePreparation
9‐2
FACIAITEMS
15”Touchscreen
19”Touchscreen
TouchscreenDimensions
HeightsandDepths DistanceforVoiceGuidance
Touchscreen
Size Touchscreen
Height x Width Touchscreen
Angle
15 inch 234 mm x 310 mm
9.21 in. x 12.20 in. 30 degrees from vertical
19 inch 305 mm x 380 mm
12.01 in. x 14.96 in. 30 degrees from vertical
5
JKL
S
$
1234 5678 9
1234 5678 9
S
S
5
JKL
S
Facia Item
Height from
base of ATM
(4-High
Dispenser Safe)
Height from
base of ATM
(5-High
Dispenser Safe)
Depth
from front
of shelf
Cheque Entry 1089 mm
(42.87 in.) 1207 mm
(47.52 in.) 218 mm
(8.58 in.)
Passbook Entry/Exit 1086 mm
(42.76 in.) 1204 mm
(47.40 in.) 218.5 mm
(8.60 in.)
Statement Exit 1084 mm
(42.68 in.) 1202 mm
(47.32 in.) 218 mm
(8.58 in.)
ID Scanner 1082 mm
(42.60 in.) 1200 mm
(47.24 in.) 236 mm
(9.29 in.)
Coin Exit 1075 mm
(42.32 in.) 1193 mm
(46.97 in.) 234 mm
(9.21 in.)
Touchscreen - Top
483 mm (19.0 in.) 1074 mm
(42.28 in.) 1192 mm
(46.93 in.) 221 mm
(8.70 in.)
Receipt 1031 mm
(40.59 in.) 1149 mm
(45.24 in.) 185 mm
(7.28 in.)
Touchscreen - Top
381 mm (15.0 in.) 1022 mm
(40.24 in.) 1140 mm
(44.88 in.) 191 mm
(7.52 in.)
Card Reader 915 mm
(36.02 in.) 1033 mm
(40.67 in.) 165 mm
(6.50 in.)
Contactless Card Reader (behind Facia) 915 mm
(36.02 in.) 1033 mm
(40.67 in.) 165 mm
(6.50 in.)
PIN Pad - Number 5 Key 849 mm
(33.43 in.) 967 mm
(38.07 in.) 136.5 mm
(5.37 in.)
Private Audio 780 mm
(30.71 in.) 898 mm
(35.35 in.) 59 mm
(2.32 in.)
Barcode Reader - Activation Point 757 mm
(29.80 in.) 875 mm
(34.45 in.) 33 mm
(1.30 in.)
Cash Exit/Entry 747 mm
(29.41 in.) 865 mm
(34.05 in.) 73 mm
(2.87 in.)
Scalable Deposit Module 747 mm
(29.41 in.) 865 mm
(34.05 in.) 73 mm
(2.87 in.)
$
5
JKL
S
1234 5678 9
No. 5 Key Audio Jack
Facia Item Distance to
Facia Item Distance to
Facia Item
Receipt 1193 mm
(7.60 in.) 1277 mm
(10.91 in.)
Card Reader 286 mm
(3.39 in.) 1169 mm
(6.65 in.)
Private Audio 6100 mm
(3.94 in.) --
Cash Exit/Entry Right
hand 7127 mm
(5.00 in.) 765 mm
(2.56 in.)
Scalable Deposit Module Right
hand 7127 mm
(5.00 in.) 765 mm
(2.56 in.)
Barcode Reader -
Activation Point 7146 mm
(5.75 in.) 873 mm
(2.87 in.)
Scalable Deposit Module Left
hand 8354 mm
(13.94 in.) 973 mm
(2.87 in.)
Cash Exit/Entry Left
hand 8354 mm
(13.94 in.) 973 mm
(2.87 in.)
Touchscreen
381 mm (15.0 in.) Centre 10 284 mm
(11.18 in.) 10 329 mm
(12.95 in.)
Touchscreen
483 mm (19.0 in.) Centre 10 290 mm
(11.42 in.) 10 341 mm
(13.43 in.)
Passbook Entry/Exit 10 314 mm
(12.36 in.) 10 396 mm
(15.59 in.)
Cheque Entry 10 481 mm
(18.82 in.) 10 545 mm
(21.46 in.)
ID Scanner 10 482 mm
(18.98 in.) 10 547 mm
(21.54 in.)
ContactlessCardReader
(behind Facia) 11 77 mm
(3.03 in.) 11 171 mm
(6.73 in.)
Coin Exit 11 275 mm
(10.83 in.) 11 365 mm
(14.37 in.)
Statement Exit 11 312 mm
(12.28 in.) 11 395 mm
(15.55 in.)
12
11
10
9
87654
3
2
1
12
11
10
9
87654
3
2
1
S
1234 5678 9
1234 5678 9
S
$

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
VariantDetails‐CENI,StandardCollarATM
NCRSelfServ™84Walk‐UpATMSitePreparation
9‐3
SECURITYBOLTS
Boltsandanchorsmustbesuppliedbytheowningorganisation.
TomeetsecuritystandardstheATMmustbeboltedtothefloor,throughallof
theboltholes,usingboltswithanchorwashersasspecifiedbelow.Boltsand
anchorwashersaretobesuppliedbytheowningorganisation.
Makesurethatthefloororplinthiscapableofwithstandingtheloading
imposedbytheanchorpointsforthesebolts.
Ifanadjustableplinthisused,itmustbeboltedtothefloortothesame
specificationastheATM.
TheminimumspecificationforboltsandwasherstosecuretheATMtoa
concreteflooris:
Bolts
Type‐eitherresinanchororshieldanchorbolts
Size‐M16(5/8in.)
MinimumLength‐150mm(5.9in.)
Strength‐hightensile(minimumISOpropertyclass8,8).
Washers
Type‐flat,steel(asperDIN7349orequivalent)
Size‐M16(5/8in.)
Outerdiameter‐nogreaterthan40mm(1.58in.)
Minimumthickness‐6mm(0.2in.).
BOLTHOLES
TheATMshouldbeboltedtothefloororplinth,throughalltheholesmarked
‘A’,usingfourboltswithanchorwashers.
Theholemarked‘B’enablesanalarmtobefitted.
ShortSleeve
LongSleeve
B
A
A
A
A
Hole in Wall
203 mm (7.99 in.)
Maximum
390 mm
(15.35 in.)
500 mm
(19.68 in.)
250 mm
(9.84 in.)
284.5 mm
(11.20 in.)
770 mm
(30.31 in.)
169.5 mm
(6.67 in.)
800 mm
(31.50 in.)
164 mm
(6.46 in.)
500 mm
(19.68 in.)
250 mm
(9.84 in.)
136 mm
(5.35 in.)
18 mm
(0.70 in.)
100.5 mm
(3.96 in.)
Hole A Bolt Holes
Hole B (Alarm Hole)
40 mm
(1.57 in.)
40 mm
(1.57 in.)
21 mm
(0.83 in.)
25 mm
(0.98 in.)
28 mm
(1.10 in.)
65 mm
(2.56 in.)
45 mm
(1.77 in.)
28 mm
(1.10 in.)
B
A
A
A
A
Hole A Bolt Holes Hole B (Alarm Hole)
330 mm
(12.99 in.)
Maximum
504 mm
(19.84 in.)
Hole in Wall
500 mm
(19.68 in.)
250 mm
(9.84 in.)
284.5 mm
(11.20 in.)
770 mm
(30.31 in.)
169.5 mm
(6.67 in.)
800 mm
(31.50 in.)
164 mm
(6.46 in.)
500 mm
(19.68 in.)
250 mm
(9.84 in.)
136 mm
(5.35 in.)
18 mm
(0.70 in.)
100.5 mm
(3.96 in.)
40 mm
(1.57 in.)
40 mm
(1.57 in.)
21 mm
(0.83 in.)
25 mm
(0.98 in.)
28 mm
(1.10 in.)
65 mm
(2.56 in.)
45 mm
(1.77 in.)
28 mm
(1.10 in.)

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
VariantDetails‐CENI,StandardCollarATM
NCRSelfServ™84Walk‐UpATMSitePreparation
9‐4
HOLEINTHEWALL
HoleatOptimumHeight
Thisheightassuresthebestdisplayviewabilityforable‐bodiedpeople.Itdoes
NOTcomplywiththeloweredheightregulationslistedinthenextsection.
4HighSecurityEnclosure
5HighSecurityEnclosure
HoleatLoweredHeight
Itistheresponsibilityoftheowninginstitutiontomakesurethattheheight
fromthesidewalkleveltothehighestoperablepointonthefacia(see‘Facia
Items’)complieswithanylocalregulations.Theinformationcontainedinthe
followingtablesincludethemaximumplinthheightsforthecountrieslisted
andareshownasexamples.
Forcorrectinstallationheightyoumustconsiderthedifferenceinheight
betweenthesidewalkandtheinteriorfloor,andinstalltheATMonaplinthif
necessary.
NotethatCENcertifiedsecurityenclosuresmusthaveaCENcertifiedplinth.
StandardCollar
Short Sleeve - maximum (7.99 in.)
Long Sleeve - maximum (12.99 in.)
203 mm
330 mm
534 mm
(21.02 in.)
368 mm
(14.49 in.)
18 mm
(0.71 in.)
*625 mm
(24.61 in.)
1026 mm
(40.39 in.)
Hole in Wall
ATM Base
View from
Inside Building
Plinth
Sidewalk
*increase to 635 mm (25.00 in.) if ATM installed with cash camera
Hole in Wall
534 mm
(21.02 in.)
*625 mm
(24.61 in.)
Short Sleeve - maximum (7.99 in.)
Long Sleeve - maximum (12.99 in.)
203 mm
330 mm
250 mm
(9.84 in.)
18 mm
(0.71 in.)
1026 mm
(40.39 in.)
ATM Base
View from
Inside Building
Plinth
Sidewalk
*increase to 635 mm (25.00 in.) if ATM installed with cash camera
Short Sleeve - maximum (7.99 in.)
Long Sleeve - maximum (12.99 in.)
203 mm
330 mm
534 mm
(21.02 in.)
B
18 mm
(0.71 in.)
*625 mm
(24.61 in.)
A
Hole in Wall
ATM Base
View from
Inside Building
Plinth
Sidewalk
*increase to 635 mm (25.00 in.) if ATM installed with cash camera
Installation Height - ATM with no modules above touchscreen
UK (CAE Parallel Approach)
4 High with 15 in.
Touchscreen 5 High with 15 in.
Touchscreen 4 High with 19 in.
Touchscreen 5 High with 19 in.
Touchscreen
A - Bottom of hole 847 mm
(33.35 in.) 847 mm
(33.35 in.) 734 mm
(28.90 in.) 776 mm
(30.55 in.)
B - Plinth height 189 mm
(7.44 in.) 71 mm
(2.80 in.) 76 mm
(2.99 in.) 0 mm
(0 in.)
USA (ADA)
4 High with 15 in.
Touchscreen 5 High with 15 in.
Touchscreen 4 High with 19 in.
Touchscreen 5 High with 19 in.
Touchscreen
A - Bottom of hole 846 mm
(33.31 in.) 846 mm
(33.31 in.) 803 mm
(31.61 in.) 803 mm
(31.61 in.)
B - Plinth height 188 mm
(7.40 in.) 70 mm
(2.76 in.) 145 mm
(5.71 in.) 27 mm
(1.06 in.)
Canada & Australia (CSA Parallel Approach)
4 High with 15 in.
Touchscreen 5 High with 15 in.
Touchscreen 4 High with 19 in.
Touchscreen 5 High with 19 in.
Touchscreen
A - Bottom of hole
CANADA
827 mm (32.56 in.)
AUSTRALIA
759 mm (29.88 in.)
CANADA
827 mm (32.56 in.)
AUSTRALIA
776 mm (30.55 in.)
759 mm
(29.88 in.) 776 mm
(30.55 in.)
B - Plinth height
CANADA
169 mm (6.65 in.)
AUSTRALIA
101 mm (3.98 in.)
CANADA
51 mm (2.01 in.)
AUSTRALIA
0 mm (0 in.)
101 mm
(3.98 in.) 0 mm
(0 in.)
Installation Height - ATM with modules above
touchscreen
UK (CAE Parallel Approach)
4 High with 15 in.
Touchscreen 5 High with 15 in.
Touchscreen
A - Bottom of hole 719 mm
(28.31 in.) 776 mm
(30.55 in.)
B - Plinth height 61 mm
(2.40 in.) 0 mm
(0 in.)
USA (ADA)
4 High with 15 in.
Touchscreen 5 High with 15 in.
Touchscreen
A - Bottom of hole 788 mm
(31.02 in.) 788 mm
(31.02 in.)
B - Plinth height 130 mm
(5.12 in.) 12 mm
(0.47 in.)
Canada & Australia (CSA Parallel
Approach)
4 High with 15 in.
Touchscreen 5 High with 15 in.
Touchscreen
A - Bottom of hole
CANADA
769 mm (30.28 in.)
AUSTRALIA
759 mm (29.88 in.)
776 mm
(30.55 in.)
B - Plinth height
CANADA
111 mm (4.37 in.)
AUSTRALIA
101 mm (3.98 in.)
0 mm
(0 in.)
DO NOT USE
NOT USED

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
VariantDetails‐CENI,StandardCollarATM
NCRSelfServ™84Walk‐UpATMSitePreparation
9‐5
HoleintheWallOverlap‐StandardCollar‐ATM VENTSLOCATION‐AIRFLOW
Unrestrictedairflowisrequiredonboththeleftandrighthandsideandatthe
rearoftheATM.Theremustbenoobstructionoftheventsatanytime.
Ifathird‐partysurround/topperisfittedthenequivalentventing,orahotair
extractionsystemmustbeinstalledwithinthesurround/topper.
CLEARANCES‐TOPBOXDOOR
CLEARANCES‐CORRIDOR
ThedimensionsshownassumetheATMisbeingmovedusingequipmentthat
doesnotextendbeyondtheATMorpackaging.
Asurroundingclearanceof6mm(0.24in.)hasbeenallowedinthedimensions.
*47 mm
(1.85 in.)
31.5 mm
(1.24 in.)
49.5 mm
(1.95 in.)
*47 mm
(1.85 in.)
*decreased to 42 mm (1.65 in.) if ATM installed with cash camera
8 mm
(0.31 in.)
371.5 mm
(14.63 in.)
24 mm
(0.94 in.)
74.5 mm
(2.93 in.)
274 mm
(10.79 in.)
221.5 mm
(8.72 in.) 93 mm
(3.66 in.)
93 mm
(3.66 in.)
119 mm
(4.68 in.)
40 mm
(1.57 in.)
48 mm
(1.89 in.)
132 mm
(5.20 in.)
262.5 mm
(10.33 in.)
*Dim A
1392 mm
(54.80 in.)
591 mm
(23.27 in.)
773 mm
(30.43 in.)
393 mm
(15.47 in.)
28 mm
(1.10 in.)
*Dim A 1903 mm (74.92 in.) - 4 High security enclosure
2021 mm (79.57 in.) - 5 High security enclosure
Packaged ATM
(pallet and
carton)
Unpackaged
ATM
ADoorway or straight corridor 970 mm
(38.19 in.) 782 mm
(30.79 in.)
BCorridor with corner 1186 mm
(46.69 in.) 1003 mm
(39.49 in.)
CRotation about centre 1713 mm
(67.44 in.) 1478 mm
(58.19 in.)
C
B
B
A

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
VariantDetails‐CENI,StandardCollarATM
NCRSelfServ™84Walk‐UpATMSitePreparation
9‐6
SERVICINGAREAS‐OPTIMUM‐SINGLEATM
TheoptimumservicingareaprovidesthebestaccesstotheATMforall
servicingandoperationtasks.
WhereverpossibletheATMshouldbeinstalledwithintheoptimumservicing
area.
IftheoptimumareaisnotavailablethenrefertoServicingAreas‐Minimum.
HowevernotethatinstallingtheATMintheminimumservicingareamay
increasetheservicingand/orupgradingtimeoveraATMinstalledusingthe
optimumarea.
AlwaysleaveasmuchspaceaspossiblearoundtheATMtofacilitatesafe
operationandservicing.
ShortSleeve LongSleeve
750 mm
(29.53 in.)
460 mm
(18.11 in.)
326 mm
(12.83 in.)
1000 mm
(39.37 in.)
2352 mm
(92.60 in.)
203 mm
(7.99 in.)
Maximum
1780 mm
(70.08 in.)
770 mm
(30.31 in.)
525 mm
(20.67 in.)
460 mm
(18.11 in.)
90 mm
(3.54 in.)
25 mm
(0.98 in.)
Rear of
security
enclosure
(door open)
750 mm
(29.53 in.)
460 mm
(18.11 in.)
326 mm
(12.83 in.)
1000 mm
(39.37 in.)
2466 mm
(97.09 in.)
330 mm
(12.99 in.)
Maximum
1780 mm
(70.08 in.)
770 mm
(30.31 in.)
525 mm
(20.67 in.)
460 mm
(18.11 in.)
90 mm
(3.54 in.)
25 mm
(0.98 in.)
Rear of
security
enclosure
(door open)

NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B006‐7519‐G000
VariantDetails‐CENI,StandardCollarATM
NCRSelfServ™84Walk‐UpATMSitePreparation
9‐7
SERVICINGAREAS‐OPTIMUM‐SIDEBYSIDE
TheoptimumservicingareaprovidesthebestaccesstotheATMforallservicingandoperationtasks.
WhereverpossibletheATMshouldbeinstalledwithintheoptimumservicingarea.
IftheoptimumareaisnotavailablethenrefertoServicingAreas‐Minimum.HowevernotethatinstallingtheATMinthe
minimumservicingareamayincreasetheservicingand/orupgradingtimeoveraATMinstalledusingtheoptimumarea.
AlwaysleaveasmuchspaceaspossiblearoundtheATMtofacilitatesafeoperationandservicing.
ShortSleeve
LongSleeve
460 mm
(18.11 in.)
3010 mm
(118.50 in.)
770 mm
(30.31 in.)
525 mm
(20.67 in.)
326 mm
(12.83 in.)
1000 mm
(39.37 in.)
2352 mm
(92.60 in.)
203 mm
(7.99 in.)
Maximum
750 mm
(29.53 in.)
460 mm
(18.11 in.)
460 mm
(18.11 in.)
90 mm
(3.54 in.)
25 mm
(0.98 in.)
Rear of
security
enclosure
(door open)
3010 mm
(118.50 in.)
770 mm
(30.31 in.)
525 mm
(20.67 in.)
326 mm
(12.83 in.)
1000 mm
(39.37 in.)
2466 mm
(97.09 in.)
330 mm
(13.00 in.)
Maximum
750 mm
(29.53 in.)
460 mm
(18.11 in.)
460 mm
(18.11 in.)
460 mm
(18.11 in.)
90 mm
(3.54 in.)
25 mm
(0.98 in.)
Rear of
security
enclosure
(door open)
Table of contents
Other NCR Cash Counter manuals
Popular Cash Counter manuals by other brands

AccuBANKER
AccuBANKER D585 user guide

Autonics
Autonics FS4A quick start guide

Precision Digital Corporation
Precision Digital Corporation PROVU Series quick start guide

Cashmaster
Cashmaster Sigma 170 user manual

HYOSUNG
HYOSUNG NH-2700T Operator's manual

Arrow International
Arrow International PrecisionCounter 500 Service manual